Usefulness of Magnetoinertial Wearable Devices in Neurorehabilitation of Children with Cerebral Palsy

Background Despite the increasing use of wearable magnetoinertial measurement units (MIMUs) for gait analysis, the efficacy of MIMU-based assessment for planning rehabilitation has not been adequately documented yet. Methods The usefulness of a MIMU-based assessment was evaluated comparing the data acquired by three MIMUs located at the pelvis, sternum, and head levels in 12 children with cerebral palsy (CP, age: 2–9 years) and 12 age-matched children with typical development (TD). Gait stability was quantified in terms of acceleration attenuation coefficients from pelvis to head, pelvis to sternum, and sternum to head. Children with CP were randomly divided in two groups: in the first group (CPI), MIMU-based parameters were used by therapists for planning patient-tailored rehabilitation programs, whereas in the second group (CPB), therapists were blind to the MIMU-based assessment results. Both CPI and CPB were tested before and after the relevant neurorehabilitation program. Ad hoc questionnaires were also administered to therapists of the CPI group to assess the degree of usefulness perceived about the information provided by the MIMU-based assessment. Results Significant differences were found between children with CP and those with TD for the acceleration attenuation coefficient from pelvis to head (p = 0.048) and from pelvis to sternum (p = 0.021). After neurorehabilitation, this last parameter increased more in CPI (35%) than in CPB (6%, p = 0.017 for the interaction group per time). The results of the questionnaires showed that therapists agreed with the usability (100% judged it as “easy to use”) and usefulness of the MIMU-based assessment in defining patient-oriented interventions (87%). Conclusions There is a large debate in literature about the efficacy of classical gait analysis that should be enlarged to new technological approaches, such as that based on MIMUs. This study is a first proof of concept about the efficacy of this approach for neurorehabilitation of children with CP.

[1]  P. Vidal,et al.  Inertial Sensors to Assess Gait Quality in Patients with Neurological Disorders: A Systematic Review of Technical and Analytical Challenges , 2017, Front. Psychol..

[2]  R. Palisano,et al.  Development and reliability of a system to classify gross motor function in children with cerebral palsy , 1997, Developmental medicine and child neurology.

[3]  H. Watts Gait laboratory analysis for preoperative decision making in spastic cerebral palsy: is it all it's cracked up to be? , 1994, Journal of pediatric orthopedics.

[4]  Angelo M. Sabatini,et al.  Estimating Orientation Using Magnetic and Inertial Sensors and Different Sensor Fusion Approaches: Accuracy Assessment in Manual and Locomotion Tasks , 2014, Sensors.

[5]  Lynn Rochester,et al.  Attenuation of Upper Body Accelerations during Gait: Piloting an Innovative Assessment Tool for Parkinson's Disease , 2015, BioMed research international.

[6]  Giovanni Morone,et al.  Development and Decline of Upright Gait Stability , 2014, Front. Aging Neurosci..

[7]  A Cappozzo,et al.  Low frequency self-generated vibration during ambulation in normal men. , 1982, Journal of biomechanics.

[8]  M. C. Bisi,et al.  Measures of gait stability: performance on adults and toddlers at the beginning of independent walking , 2014, Journal of NeuroEngineering and Rehabilitation.

[9]  Aurelio Cappozzo,et al.  Control of the upper body accelerations in young and elderly women during level walking , 2008, Journal of NeuroEngineering and Rehabilitation.

[10]  H. Merk,et al.  The utility of gait analysis in the rehabilitation of patients after surgical treatment of Achilles tendon rupture , 2002, European Journal of Orthopaedic Surgery & Traumatology.

[11]  Aurelio Cappozzo,et al.  Assessing locomotor skills development in childhood using wearable inertial sensor devices: the running paradigm. , 2013, Gait & posture.

[12]  S. Tashman,et al.  Pre- and Postoperative Gait Analysis in Patients with Spastic Diplegia: A Preliminary Report , 1984, Journal of pediatric orthopedics.

[13]  Wiebren Zijlstra,et al.  Accelerometry based assessment of gait parameters in children. , 2006, Gait & posture.

[14]  K. Desloovere,et al.  Three-dimensional head and trunk movement characteristics during gait in children with spastic diplegia. , 2013, Gait & posture.

[15]  F. Riva,et al.  Estimating fall risk with inertial sensors using gait stability measures that do not require step detection. , 2013, Gait & posture.

[16]  Vanina Dal Bello-Haas,et al.  The Potential of Gait Analysis to Contribute to Differential Diagnosis of Early Stage Dementia: Current Research and Future Directions* , 2007, Canadian Journal on Aging / La Revue canadienne du vieillissement.

[17]  Giuseppe Vannozzi,et al.  The iFST: An instrumented version of the Fukuda Stepping Test for balance assessment. , 2018, Gait & posture.

[18]  A. Hof Scaling gait data to body size , 1996 .

[19]  K. Desloovere,et al.  Altered trunk movements during gait in children with spastic diplegia: compensatory or underlying trunk control deficit? , 2014, Research in developmental disabilities.

[20]  T. Isho,et al.  Association of trunk control with mobility performance and accelerometry-based gait characteristics in hemiparetic patients with subacute stroke. , 2016, Gait & posture.

[21]  S. Paolucci,et al.  Stability and harmony of gait in children with cerebral palsy. , 2011, Research in developmental disabilities.

[22]  Federica Verdini,et al.  SIAMOC position paper on gait analysis in clinical practice: General requirements, methods and appropriateness. Results of an Italian consensus conference. , 2017, Gait & posture.

[23]  Stefano Paolucci,et al.  Wearable inertial sensors for human movement analysis , 2016, Expert review of medical devices.

[24]  Giuseppe Vannozzi,et al.  Multi-sensor assessment of dynamic balance during gait in patients with subacute stroke. , 2017, Journal of biomechanics.

[25]  Aurelio Cappozzo,et al.  Multilevel Upper Body Movement Control during Gait in Children with Cerebral Palsy , 2016, PloS one.

[26]  A. Timmermans,et al.  Interactive wearable systems for upper body rehabilitation: a systematic review , 2017, Journal of NeuroEngineering and Rehabilitation.

[27]  Torsten Bumgarner,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[28]  Manuela Galli,et al.  Summary measures for clinical gait analysis: a literature review. , 2014, Gait & posture.

[29]  Reinald Brunner,et al.  Evaluating upper body movements during gait in healthy children and children with diplegic cerebral palsy , 2007, Journal of pediatric orthopedics. Part B.

[30]  Hylton B Menz,et al.  Accelerometry: a technique for quantifying movement patterns during walking. , 2008, Gait & posture.

[31]  A. Berthoz,et al.  Head and Body Coordination during Locomotion and Complex Movements , 1994 .

[32]  K. Lowry,et al.  Walking stability using harmonic ratios in Parkinson's disease , 2009, Movement disorders : official journal of the Movement Disorder Society.