Electrochemical Instrumentation of a Hip Simulator: A New Tool for Assessing the Role of Corrosion in Metal-On-Metal Hip Joints

Polyethylene wear debris induced osteolysis has triggered investigations to find alternative material combinations to the well-established metal-on-polyethylene hip implants. Owing to some early successful clinical cases, metal-on-metal (MoM) hip replacements have been attracting more and more interest. There is, however, considerable concern about the propensity of MoM hip replacements to release metal ions and fine, nanometre-scale metallic wear debris. The long-term effect from released metal ions and wear particles is still not clear. To date, all the work on hip simulators focused on assessing mass losses damage has been referred to as ‘wear’. However, it is known in the field of tribocorrosion that mechanical removal of the passive layer on Co—Cr alloys can significantly enhance corrosion activity. In total joint replacements, it is possible that corrosion plays a significant role. However, no one has ever tried to extract, on a hip simulator, what proportion of the damage is due to mechanical processes and the corrosion processes. This paper describes the first instrumentation of an integrated hip joint simulator to provide in-situ electrochemical measurements in real time. The open circuit potential results are reported to assess the corrosion regime in the absence and presence of movement at the bearing surfaces. The importance of these measurements is that the real damage mechanisms can be assessed as a function of the operating cycle.

[1]  D. Dowson,et al.  The influence of swing phase load on the electrochemical response, friction, and ion release of metal-on-metal hip prostheses in a friction simulator , 2009 .

[2]  D. Dowson,et al.  Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses , 2008 .

[3]  D. Dowson,et al.  Biotribocorrosion of CoCrMo orthopaedic implant materials : Assessing the formation and effect of the biofilm , 2007 .

[4]  D Dowson,et al.  New joints for the Millennium: Wear control in total replacement hip joints , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  J. Jacobs,et al.  Hypersensitivity to metallic biomaterials: a review of leukocyte migration inhibition assays. , 2000, Biomaterials.

[6]  J. Galante,et al.  Metal Release in Patients Who Have Had a Primary Total Hip Arthroplasty. A Prospective, Controlled, Longitudinal Study* , 1998, The Journal of bone and joint surgery. American volume.

[7]  P. Campbell,et al.  Metal on metal total hip replacement workshop consensus document. , 1996, Clinical orthopaedics and related research.

[8]  P. Campbell,et al.  Metal versus polyethylene wear particles in total hip replacements. A review. , 1996, Clinical orthopaedics and related research.

[9]  O. Wahlström,et al.  20-Year Results of McKee-Farrar Versus Charnley Prosthesis , 1996 .

[10]  W. Healy Economic considerations in total hip arthroplasty and implant standardization. , 1995, Clinical orthopaedics and related research.

[11]  M. Müller The benefits of metal-on-metal total hip replacements. , 1995, Clinical orthopaedics and related research.

[12]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[13]  J. Charnley,et al.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. , 1972, The Journal of bone and joint surgery. British volume.

[14]  G K McKee,et al.  Replacement of arthritic hips by the McKee-Farrar prosthesis. , 1966, The Journal of bone and joint surgery. British volume.

[15]  J N Wilson,et al.  Epiphyseal transplantation. A clinical study. , 1966, The Journal of bone and joint surgery. American volume.

[16]  O. Wahlström,et al.  Twenty-year results of McKee-Farrar versus Charnley prosthesis. , 1996, Clinical orthopaedics and related research.

[17]  J. Charnley Long-term results of low-friction arthroplasty. , 1982, The Hip.