MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh.

In this study, we propose a focused ultrasound surgery protocol that induces and then uses gas bubbles at the focus to enhance the ultrasound absorption and ultimately create larger lesions in vivo. MRI and ultrasound visualization and monitoring methods for this heating method are also investigated. Larger lesions created with a carefully monitored single ultrasound exposure could greatly improve the speed of tumour coagulation with focused ultrasound. All experiments were performed under MRI (clinical, 1.5 T) guidance with one of two eight-sector, spherically curved piezoelectric transducers. The transducer, either a 1.1 or 1.7 MHz array, was driven by a multi-channel RF driving system. The transducer was mounted in an MRI-compatible manual positioning system and the rabbit was situated on top of the system. An ultrasound detector ring was fixed with the therapy transducer to monitor gas bubble activity during treatment. Focused ultrasound surgery exposures were delivered to the thighs of seven New Zealand while rabbits. The experimental, gas-bubble-enhanced heating exposures consisted of a high amplitude 300 acoustic watt, half second pulse followed by a 7 W, 14 W or 21 W continuous wave exposure for 19.5 s. The respective control sonications were 20 s exposures of 14 W, 21 W and 28 W. During the exposures, MR thermometry was obtained from the temperature dependency of the proton resonance frequency shift. MRT2-enhanced imaging was used to evaluate the resulting lesions. Specific metrics were used to evaluate the differences between the gas-bubble-enhanced exposures and their respective control sonications: temperatures with respect to time and space, lesion size and shape, and their agreement with thermal dose predictions. The bubble-enhanced exposures showed a faster temperature rise within the first 4 s and higher overall temperatures than the sonications without bubble formation. The spatial temperature maps and the thermal dose maps derived from the MRI thermometry closely correlated with the resulting lesion as examined by T2-weighted imaging. The lesions created with the gas-bubble-enhanced heating exposures were 2-3 times larger by volume, consistently more spherical in shape and closer to the transducer than the control exposures. The study demonstrates that gas bubbles can reliably be used to create significantly larger lesions in vivo. MRI thermometry techniques were successfully used to monitor the thermal effects mediated by the bubble-enhanced exposures.

[1]  L. Frizzell,et al.  Thresholds for Focal Ultrasonic Lesions in Rabbit Kidney, Liver, and Testicle , 1977, IEEE Transactions on Biomedical Engineering.

[2]  Ronald A. Roy,et al.  Thresholds for cavitation produced in water by pulsed ultrasound. , 1988, Ultrasonics.

[3]  R. Daoust,et al.  Sensitivity to RNase treatment of ribosomes and rRNA from normal rat liver and Novikoff hepatoma. , 1982, British Journal of Cancer.

[4]  K. Hynynen,et al.  MRI-guided noninvasive ultrasound surgery. , 1993, Medical physics.

[5]  H. G. Flynn Generation of transient cavities in liquids by microsecond pulses of ultrasound , 1982 .

[6]  R. C. Eggleton,et al.  Threshold ultrasonic dosages for structural changes in the mammalian brain. , 1970, The Journal of the Acoustical Society of America.

[7]  C. Cain,et al.  Non-invasive ultrasound surgery: role of microbubble enhanced cavitation , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[8]  A. Szent-Györgyi,et al.  Chemical and Biological Effects of Ultra-Sonic Radiation , 1933, Nature.

[9]  F. Fry,et al.  Transrectal ablation of prostate tissue using focused ultrasound , 1993 .

[10]  F A Jolesz,et al.  Focused US system for MR imaging-guided tumor ablation. , 1995, Radiology.

[11]  Xiaobing Fan,et al.  Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  F L Lizzi,et al.  Analytical modelling of ultrasonically induced tissue heating. , 1987, Ultrasound in medicine & biology.

[13]  K. Hynynen,et al.  Design and evaluation of a feedback based phased array system for ultrasound surgery , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  G. Haar,et al.  Ultrasound focal beam surgery. , 1995 .

[15]  K Hynynen,et al.  Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo. , 1995, Ultrasound in medicine & biology.

[16]  D. Chopin,et al.  Focused extracorporeal pyrotherapy: experimental study and feasibility in man. , 1993, Seminars in urology.

[17]  P. Edmonds,et al.  Evidence for free radical production by ultrasonic cavitation in biological media. , 1983, Ultrasound in medicine & biology.

[18]  Chris J Diederich,et al.  MRI‐guided thermal therapy of transplanted tumors in the canine prostate using a directional transurethral ultrasound applicator , 2002, Journal of magnetic resonance imaging : JMRI.

[19]  Kullervo Hynynen,et al.  MRI evaluation of thermal ablation of tumors with focused ultrasound , 1998, Journal of magnetic resonance imaging : JMRI.

[20]  Ronald A. Roy,et al.  Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. , 2001, Ultrasound in medicine & biology.

[21]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[22]  K Butts,et al.  Study of focused ultrasound tissue damage using MRI and histology , 1999, Journal of magnetic resonance imaging : JMRI.

[23]  C R Hill,et al.  Lesion development in focused ultrasound surgery: a general model. , 1994, Ultrasound in medicine & biology.

[24]  F A Jolesz,et al.  A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.

[25]  F A Jolesz,et al.  Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. , 2000, Radiology.

[26]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[27]  S D Prionas,et al.  The effects of hyperthermia on normal mesenchymal tissues. Application of a histologic grading system. , 1983, Archives of pathology & laboratory medicine.

[28]  K. Kawabata,et al.  Effect of second-harmonic phase on producing sonodynamic tissue damage , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[29]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[30]  W. K. Law,et al.  Finite amplitude effects on the thresholds for lesion production in tissues by unfocused ultrasound , 1981 .

[31]  R. Apfel Acoustic cavitation: a possible consequence of biomedical uses of ultrasound. , 1982, The British journal of cancer. Supplement.

[32]  K Hynynen,et al.  Noninvasive arterial occlusion using MRI-guided focused ultrasound. , 1996, Ultrasound in medicine & biology.

[33]  W J FRY,et al.  Fundamental neurological research and human neurosurgery using intense ultrasound. , 1960, IRE transactions on medical electronics.

[34]  J. MacFall,et al.  Non-invasive thermometry using magnetic resonance diffusion imaging: potential for application in hyperthermic oncology. , 1992, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[35]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[36]  K. Hynynen,et al.  The feasibility of MRI-guided whole prostate ablation with a linear aperiodic intracavitary ultrasound phased array. , 2000, Physics in medicine and biology.

[37]  G. ter Haar,et al.  Temperature rise recorded during lesion formation by high-intensity focused ultrasound. , 1997, Ultrasound in medicine & biology.

[38]  F A Jolesz,et al.  Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. , 1999, Medical physics.

[39]  J Y Chapelon,et al.  Focused liver ablation by cavitation in the rabbit: a potential new method of extracorporeal treatment. , 1994, Gut.