Generalized Design of High Performance Shunt Active Power Filter With Output LCL Filter

This paper concentrates on the design, control, and implementation of an LCL-filter-based shunt active power filter (SAPF), which can effectively compensate for harmonic currents produced by nonlinear loads in a three-phase three-wire power system. With an LCL filter added at its output, the proposed SAPF offers superior switching harmonic suppression using much reduced passive filtering elements. Its output currents thus have high slew rate for tracking the targeted reference closely. Smaller inductance of the LCL filter also means smaller harmonic voltage drop across the passive output filter, which in turn minimizes the possibility of overmodulation, particularly for cases where high modulation index is desired. These advantages, together with overall system stability, are guaranteed only through proper consideration of critical design and control issues, like the selection of LCL parameters, interactions between resonance damping and harmonic compensation, bandwidth design of the closed-loop system, and active damping implementation with fewer current sensors. These described design concerns, together with their generalized design procedure, are applied to an analytical example, and eventually verified by both simulation and experimental results.

[1]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[2]  Yan Zhou,et al.  Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[3]  Jano Malvar,et al.  Effects of Discretization Methods on the Performance of Resonant Controllers , 2010, IEEE Transactions on Power Electronics.

[4]  Mariusz Malinowski,et al.  A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter , 2008, IEEE Transactions on Industrial Electronics.

[5]  Marco Liserre,et al.  Grid-Filter Design for a Multimegawatt Medium-Voltage Voltage-Source Inverter , 2011, IEEE Transactions on Industrial Electronics.

[6]  Dehong Xu,et al.  A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter , 2010, IEEE Transactions on Industrial Electronics.

[7]  Dehong Xu,et al.  An Improved Control Strategy for Grid-Connected Voltage Source Inverters With an LCL Filter , 2006, IEEE Transactions on Power Electronics.

[8]  M. Tavakoli Bina,et al.  An efficient procedure to design passive LCL-filters for active power filters , 2009 .

[9]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[10]  P.W. Lehn,et al.  Digital Current Control of a Voltage Source Converter With Active Damping of LCL Resonance , 2006, IEEE Transactions on Power Electronics.

[11]  Poh Chiang Loh,et al.  Improved one-cycle-control scheme for three-phase active rectifiers with input inductor-capacitor-inductor filters , 2011 .

[12]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[13]  Xinbo Ruan,et al.  Full Feedforward of Grid Voltage for Grid-Connected Inverter With LCL Filter to Suppress Current Distortion Due to Grid Voltage Harmonics , 2010, IEEE Transactions on Power Electronics.

[14]  Friedrich Wilhelm Fuchs,et al.  Active Damping for Three-Phase PWM Rectifiers With High-Order Line-Side Filters , 2009, IEEE Transactions on Industrial Electronics.

[15]  Steffen Bernet,et al.  Design of $LCL$ Filters of Active-Front-End Two-Level Voltage-Source Converters , 2009, IEEE Transactions on Industrial Electronics.

[16]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2003 .

[17]  O. Vodyakho,et al.  Three-Level Inverter-Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems , 2009, IEEE Transactions on Power Electronics.

[18]  J.W. Kolar,et al.  A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through $LCL$ Filters , 2005, IEEE Transactions on Industry Applications.

[19]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[20]  Guozhu Chen,et al.  A novel control approach for LCL-based shunt active power filter with high dynamic and steady-state performance , 2008, 2008 IEEE Power Electronics Specialists Conference.

[21]  Vinod John,et al.  Filter Optimization for Grid Interactive Voltage Source Inverters , 2010, IEEE Transactions on Industrial Electronics.

[22]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[23]  Frede Blaabjerg,et al.  Proportionalresonant controllers and filters for gridconnected voltagesource converters , 2006 .

[24]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[25]  J.W. Kolar,et al.  A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[26]  H. Tuusa,et al.  LCL Type Supply Filter for Active Power Filter - Comparison of an Active and a Passive Method for Resonance Damping , 2007, 2007 IEEE Power Electronics Specialists Conference.

[27]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[28]  G. Garcera,et al.  Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter , 2009, IEEE Transactions on Industrial Electronics.

[29]  Robert Turner,et al.  Stability and Bandwidth Implications of Digitally Controlled Grid-Connected Parallel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[30]  Poh Chiang Loh,et al.  Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters , 2005, IEEE Transactions on Industry Applications.