Accelerometers in rehabilitation medicine for older adults.

Recent technological developments have led to the production of inexpensive, miniature accelerometer sensors with potential for use in a clinical setting. These sensors can provide reliable information on mobility and objective measurement of gait. They are currently used mainly in a research setting; however, with recent advances, incorporation into clinical practice is possible. For illustrative purposes this paper describes some current applications of accelerometers in gait and balance evaluation, falls risk assessment and mobility monitoring. Accelerometers provide quantitative measures of gait, they are capable of identifying specific gait changes in older adults and in fallers and can be used to objectively quantify ambulatory activity levels. Accelerometers have many potential uses in monitoring of patients in rehabilitation. They provide an added objective and quantitative dimension to gait analysis when combined with clinical assessment. They have the potential in the future to stratify falls risk facilitating early initiation of appropriate therapeutic intervention, thus reducing further falls. The challenge facing clinicians and biomedical engineers is to further harness this technology making it part of everyday clinical practice.

[1]  J. Bussmann,et al.  Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study , 1998, Pain.

[2]  Ja White,et al.  Standardization and definitions of the sit-stand-sit movement cycle , 1994 .

[3]  J B Bussmann,et al.  Techniques for measurement and assessment of mobility in rehabilitation: a theoretical approach , 1998, Clinical rehabilitation.

[4]  E. Carr Observational methods in rehabilitation research , 1991 .

[5]  R. V. van Lummel,et al.  The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes. , 2006, Journal of biomechanics.

[6]  Manfred Smeja,et al.  24-h Assessment of Tremor Activity and Posture in Parkinson's Disease by Multi-Channel Accelerometry , 1999 .

[7]  J. Bussmann,et al.  Quantification of physical activities by means of ambulatory accelerometry: a validation study. , 1998, Psychophysiology.

[8]  D E Krebs,et al.  Reliability of observational kinematic gait analysis. , 1985, Physical therapy.

[9]  J. Kooloos,et al.  Reliability of videotaped observational gait analysis in patients with orthopedic impairments , 2005, BMC musculoskeletal disorders.

[10]  L. Snyder-Mackler,et al.  Interrater reliability of videotaped observational gait-analysis assessments. , 1991, Physical therapy.

[11]  R S Barrett,et al.  Upper body accelerations during walking in healthy young and elderly men. , 2004, Gait & posture.

[12]  H. Yack,et al.  Dynamic stability in the elderly: identifying a possible measure. , 1993, Journal of gerontology.

[13]  V. van der Meer,et al.  Accuracy of Objective Ambulatory Accelerometry in Detecting Motor Complications in Patients With Parkinson Disease , 2004, Clinical neuropharmacology.

[14]  A. Manley Physical Activity And Health: A Report Of The Surgeon General , 2004 .

[15]  K. Kerr,et al.  Analysis of the sit-stand-sit movement cycle in normal subjects. , 1997, Clinical biomechanics.

[16]  J B Bussmann,et al.  Validity of ambulatory accelerometry to quantify physical activity in heart failure. , 2000, Scandinavian journal of rehabilitation medicine.

[17]  G M Lyons,et al.  Long-term mobility monitoring of older adults using accelerometers in a clinical environment , 2004, Clinical rehabilitation.

[18]  J. B. J. Bussmann,et al.  Measuring daily behavior using ambulatory accelerometry: The Activity Monitor , 2001, Behavior research methods, instruments, & computers : a journal of the Psychonomic Society, Inc.

[19]  Howard Gage,et al.  Accelerographic analysis of human gait , 1967 .

[20]  B. Auvinet,et al.  Reference data for normal subjects obtained with an accelerometric device. , 2002, Gait & posture.

[21]  J. Saunders,et al.  The major determinants in normal and pathological gait. , 1953, The Journal of bone and joint surgery. American volume.

[22]  G Kamen,et al.  Detecting Balance Deficits in Frequent Fallers Using Clinical and Quantitative Evaluation Tools , 1998, Journal of the American Geriatrics Society.

[23]  R. Fitzpatrick,et al.  Acceleration patterns of the head and pelvis when walking on level and irregular surfaces. , 2003, Gait & posture.

[24]  Kamiar Aminian,et al.  Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly , 2002, IEEE Transactions on Biomedical Engineering.

[25]  P H Veltink,et al.  Detection of static and dynamic activities using uniaxial accelerometers. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[26]  Kamiar Aminian,et al.  Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly , 2003, IEEE Transactions on Biomedical Engineering.

[27]  Robert Puers,et al.  A telemetry system for the detection of hip prosthesis loosening by vibration analysis , 2000 .

[28]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[29]  P. Veltink,et al.  Validity and reliability of measurements obtained with an "activity monitor" in people with and without a transtibial amputation. , 1998, Physical therapy.

[30]  Mark T. Jones,et al.  Electronic textiles for in situ biomechanical measurements , 2004 .

[31]  M. Tinetti,et al.  Risk factors for falls among elderly persons living in the community. , 1988, The New England journal of medicine.

[32]  R. Fitzpatrick,et al.  Age-related differences in walking stability. , 2003, Age and ageing.