Influence of filler/reinforcing agent and post-curing on the flexural properties of woven and unidirectional glass fiber-reinforced composites

The aim of this study is to investigate the reinforcing effect of woven and unidirectional glass fibers and the effect of post-curing on the flexural strength and flexural modulus of glass fiber-reinforced composites. A series of composites containing 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropoxy)-phenyl]propane and triethyleneglycol dimethacrylate matrices and different reinforcements of unidirectional or woven glass fibers were prepared. The samples, 25 × 2 × 2 mm, were cured with a halogen curing lamp, followed by additional curing by thermal treatment at 135 ± 5 °C temperature and 60 psi pressure. Samples were tested before and after post-curing in order to determine the flexural strength and flexural modulus. The degree of reinforcement with glass fibers was varied between 14 and 57 wt% or 7.64 and 38.44 vol% by changing the number of unidirectional bundles or woven glass fiber bands in the composites, respectively. The obtained flexural strength values were in the range of 95.20–552.31 Mpa; the flexural modulus ranged between 2.17 and 14.7 GPa. The highest flexural strength and flexural modulus values were recorded for samples with unidirectional glass fibers. The mechanical qualities of the glass fibers-reinforced composites increased after post-curing treatment. Increasing of the glass fiber amount in the experimental composites improves both flexural strength and modulus. SEM micrographs of fractured composites indicate a strong interfacial interaction between the glass fibers and the polymer matrix.

[1]  T. W. Clyne,et al.  An Introduction to Composite Materials: Fabrication , 1996 .

[2]  F. Wallenberger,et al.  Natural Fibers, Plastics and Composites , 2004 .

[3]  K. Inoue,et al.  Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[4]  N. Wakabayashi,et al.  Reinforcement effects of fiberglass on telescopic dentures using a three-dimensional finite element analysis and fracture test. , 2009, Dental materials journal.

[5]  A. Karaman,et al.  Four applications of reinforced polyethylene fiber material in orthodontic practice. , 2002, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[6]  L. H. Sperling,et al.  Introduction to Physical Polymer Science: Sperling/Introduction to Physical Polymer Science, Fourth Edition , 2005 .

[7]  P. Vallittu,et al.  Residual monomers and degree of conversion of partially bioresorbable fiber-reinforced composite. , 2006, Acta biomaterialia.

[8]  P. Vallittu Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers. , 1999, The Journal of prosthetic dentistry.

[9]  Hatch Ra Fiber‐reinforced Composites in Clinical Dentistry , 2001 .

[10]  L. Sperling Introduction to physical polymer science , 1986 .

[11]  P. Vallittu,et al.  Water sorption, solubility and effect of post-curing of glass fibre reinforced polymers. , 1999, Biomaterials.

[12]  S. Tsai,et al.  Introduction to composite materials , 1980 .

[13]  R. Lappalainen,et al.  Acrylic resin-fiber composite--Part I: The effect of fiber concentration on fracture resistance. , 1994, The Journal of prosthetic dentistry.

[14]  S. Ban,et al.  Flexural properties of denture base polymers reinforced with a glass cloth-urethane polymer composite. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[15]  S. Aquilino,et al.  The effect of carbon graphite fiber reinforcement on the strength of provisional crown and fixed partial denture resins. , 1991, The Journal of prosthetic dentistry.

[16]  P. Vallittu Compositional and weave pattern analyses of glass fibers in dental polymer fiber composites. , 1998, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[17]  S G Vermilyea,et al.  The effect of carbon fiber orientation on the fatigue resistance and bending properties of two denture resins. , 1984, The Journal of prosthetic dentistry.

[18]  P. Vallittu Comparison of the in vitro fatigue resistance of an acrylic resin removable partial denture reinforced with continuous glass fibers or metal wires. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[19]  M. Marei Reinforcement of denture base resin with glass fillers. , 1999, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[20]  D. Watts,et al.  Effect of glass-fiber reinforcement and water storage on fracture toughness (KIC) of polymer-based provisional crown and FPD materials. , 2004, The International journal of prosthodontics.

[21]  F. Rueggeberg,et al.  The effect of post-cure heating on residual, unreacted monomer in a commercial resin composite. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[22]  M. Yoshinari,et al.  Mechanical properties of roots combined with prefabricated fiber post. , 2009, Dental materials journal.

[23]  P. Vallittu,et al.  Bone tissue responses to glass fiber-reinforced composite implants--a histomorphometric study. , 2009, Clinical oral implants research.

[24]  P. Vallittu,et al.  Curing of a silane coupling agent and its effect on the transverse strength of autopolymerizing polymethylmethacrylate-glass fibre composite. , 1997, Journal of oral rehabilitation.

[25]  E. Pfau,et al.  Rehabilitation of periodontally compromised teeth with fiber-reinforced composite resin: a case report. , 2011, Quintessence international.

[26]  Jean-François Gérard,et al.  Interphase modification in unidirectional glass-fiber epoxy composites , 1998 .

[27]  P. Vallittu The effect of void space and polymerization time on transverse strength of acrylic-glass fibre composite. , 1995, Journal of oral rehabilitation.

[28]  G. Aksoy,et al.  Rehabilitation of advanced periodontal problems by using a combination of a glass fiber-reinforced composite resin bridge and splint. , 2008, The journal of adhesive dentistry.

[29]  P. Vallittu,et al.  Short glass fiber reinforced restorative composite resin with semi-inter penetrating polymer network matrix. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[30]  Nandini Suresh Indirect resin composites , 2010, Journal of conservative dentistry : JCD.

[31]  P. Vallittu,et al.  Impact strength of a modified continuous glass fiber--poly(methyl methacrylate). , 1997, The International journal of prosthodontics.

[32]  J L Ferracane,et al.  Post-cure heat treatments for composites: properties and fractography. , 1992, Dental materials : official publication of the Academy of Dental Materials.

[33]  Anil Ardeshna Clinical evaluation of fiber-reinforced-plastic bonded orthodontic retainers. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[34]  P. Vallittu,et al.  Effect of fiber position and orientation on fracture load of fiber-reinforced composite. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[35]  O. Karacaer,et al.  The effect of length and concentration of glass fibers on the mechanical properties of an injection- and a compression-molded denture base polymer. , 2003, The Journal of prosthetic dentistry (Print).

[36]  I. Kangasniemi,et al.  Depth of light-initiated polymerization of glass fiber-reinforced composite in a simulated root canal. , 2003, The International journal of prosthodontics.

[37]  H. D. Stipho Repair of acrylic resin denture base reinforced with glass fiber. , 1998, The Journal of prosthetic dentistry.

[38]  A. Freilich Fiber-Reinforced Composites in Clinical Dentistry , 2000 .

[39]  I. Ward,et al.  Acrylic resin reinforced with chopped high performance polyethylene fiber--properties and denture construction. , 1993, Dental materials : official publication of the Academy of Dental Materials.

[40]  Martin Rosentritt,et al.  Fiber-reinforced composite crowns and FPDs: a clinical report. , 2003, The International journal of prosthodontics.

[41]  L. C. Christensen,et al.  The effect of plasma-treated polyethylene fiber on the fracture strength of polymethyl methacrylate. , 1996, The Journal of prosthetic dentistry.

[42]  J. P. Duncan,et al.  The design and fabrication of fiber-reinforced implant prostheses. , 2002, The Journal of prosthetic dentistry.

[43]  P. Vallittu Ultra-high-modulus polyethylene ribbon as reinforcement for denture polymethyl methacrylate: a short communication. , 1997, Dental materials : official publication of the Academy of Dental Materials.

[44]  Vistasp M Karbhari,et al.  Effect of fiber architecture on flexural characteristics and fracture of fiber-reinforced dental composites. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[45]  S. Östlund,et al.  Fatigue Propagation of Fibre-Bridged Cracks in Unidirectional Polymer-Matrix Composites , 2001 .