Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging

Currently, the nonadaptive delay-and-sum (DAS) beamformer is extensively used for ultrasound imaging, despite the fact that it has lower resolution and worse interference suppression capability than the adaptive standard Capon beamformer (SCB) if the steering vector corresponding to the signal of interest (SOI) is accurately known. The main problem which restricts the use of SCB, however, is that SCB lacks robustness against steering vector errors that are inevitable in practice. Whenever this happens, the performance of SCB may become worse than that of DAS. Therefore, a robust adaptive beamformer is desirable to maintain the robustness of DAS and adaptivity of SCB. In this paper we consider a recent promising robust Capon beamformer (RCB) for ultrasound imaging. We propose two ways of implementing RCB, one based on time delay and the other based on time reversal. RCB extends SCB by allowing the array steering vector to be within an uncertainty set. Hence, it restores the appeal of SCB including its high resolution and superb interference suppression capabilities, and also retains the attractiveness of DAS including its robustness against steering vector errors. The time-delay-based RCB can tolerate the misalignment of data samples and the time-reversal-based RCB can withstand the uncertainty of the Green's function. Both time-delay-based RCB and time-reversal-based RCB can be efficiently computed at a comparable cost to SCB. The excellent performances of the proposed robust adaptive beamforming approaches are demonstrated via a number of simulated and experimental examples.

[1]  Hareo Hamada,et al.  Adaptive inverse filters for stereophonic sound reproduction , 1992, IEEE Trans. Signal Process..

[2]  Henry Cox,et al.  Robust adaptive beamforming , 2005, IEEE Trans. Acoust. Speech Signal Process..

[3]  Liliana Borcea,et al.  Statistically stable ultrasonic imaging in random media. , 2002, The Journal of the Acoustical Society of America.

[4]  Antonio Cantoni,et al.  An alternative formulation for an optimum beamformer with robustness capability , 1985 .

[5]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Zhi Tian,et al.  A recursive least squares implementation for LCMP beamforming under quadratic constraint , 2001, IEEE Trans. Signal Process..

[7]  W. Chew,et al.  Reconstruction of two-dimensional permittivity distribution using the distorted Born iterative method. , 1990, IEEE transactions on medical imaging.

[8]  T. Marzetta A new interpretation of Capon's maximum likelihood method of frequency-wavenumber spectral estimation , 1983 .

[9]  R. Walker,et al.  Bearing accuracy and resolution bounds of high-resolution beamformers , 1985, ICASSP '85. IEEE International Conference on Acoustics, Speech, and Signal Processing.

[10]  B. Carlson Covariance matrix estimation errors and diagonal loading in adaptive arrays , 1988 .

[11]  Hong Wang,et al.  Coherent signal-subspace processing for the detection and estimation of angles of arrival of multiple wide-band sources , 1985, IEEE Trans. Acoust. Speech Signal Process..

[12]  Mathias Fink Time-reversal mirrors , 1993 .

[13]  Jian Li,et al.  Robust Capon beamforming , 2002, Conference Record of the Thirty-Sixth Asilomar Conference on Signals, Systems and Computers, 2002..

[14]  J. Devaney,et al.  1 Super-resolution Processing of Multi-static Data Using Time Reversal and MUSIC A , 2000 .

[15]  E. Ebbini,et al.  Imaging strongly scattering media using a multiple frequency distorted Born iterative method , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  M. Fink Time reversed acoustics , 2001 .

[17]  R. O. Schmidt,et al.  Multiple emitter location and signal Parameter estimation , 1986 .

[18]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Seth D. Silverstein,et al.  Analytical comparison of sensor signal processing enhancements for NDT synthetic aperture ultrasonic imaging , 1993, IEEE Trans. Image Process..

[20]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[21]  Mostafa Kaveh,et al.  Focussing matrices for coherent signal-subspace processing , 1988, IEEE Trans. Acoust. Speech Signal Process..

[22]  Mathias Fink,et al.  Decomposition of the time reversal operator: Detection and selective focusing on two scatterers , 1996 .

[23]  Barry D. Van Veen Minimum variance beamforming with soft response constraints , 1991, IEEE Trans. Signal Process..

[24]  Ju-Hong Lee,et al.  Robust adaptive array beamforming under steering vector errors , 1997 .

[25]  Lloyd J. Griffiths,et al.  A projection approach for robust adaptive beamforming , 1994, IEEE Trans. Signal Process..

[26]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[27]  Petre Stoica,et al.  Introduction to spectral analysis , 1997 .

[28]  Jeffrey L. Krolik,et al.  Multiple broad-band source location using steered covariance matrices , 1989, IEEE Trans. Acoust. Speech Signal Process..

[29]  Claire Prada,et al.  Experimental subwavelength localization of scatterers by decomposition of the time reversal operator interpreted as a covariance matrix. , 2003, The Journal of the Acoustical Society of America.

[30]  Jian Li,et al.  On robust Capon beamforming and diagonal loading , 2003, 2003 IEEE International Conference on Acoustics, Speech, and Signal Processing, 2003. Proceedings. (ICASSP '03)..

[31]  Kyritsi,et al.  MISO time reversal and delay-spread compression for FWA channels at 5 GHz , 2004, IEEE Antennas and Wireless Propagation Letters.

[32]  B.D. Steinberg,et al.  Digital beamforming in ultrasound , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  W. Kuperman,et al.  Iterative time reversal in the ocean , 1997 .

[34]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[35]  X. Li,et al.  Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensions , 2002, IEEE Transactions on Biomedical Engineering.

[36]  G. Papanicolaou,et al.  Imaging and time reversal in random media , 2001 .