Rotational core loss test setup: Design and measurement

Rotational core loss data is required for core loss estimation in electrical machines. This necessitates the design of 2D magnetizers to accurately measure these losses. However, the accuracy of any 2D magnetizer is contingent on its ability to maintain a uniform field distribution in the sample, at least in the measurement area, for all flux density levels and magnetization directions. Moreover, the measurement area should be large enough to allow measurements over a wide sample area, which effectively represents the material properties. A 2D magnetizer is designed to allow a measurement area of 65 by 65 mm on a 136 mm diameter circular sample. The magnetizer was prototyped and preliminary core loss measurements presented for both pulsating and rotational core losses using M19G29 steel at 60 Hz.

[1]  Carlo Stefano Ragusa,et al.  Magnetic losses under two-dimensional flux loci in Fe-Si laminations , 2007 .

[2]  Anthony John Moses,et al.  An intercomparison of rotational loss measurements in non oriented Fe-Si alloys , 2008 .

[3]  M.D. Ross Time-temperature tests to determine machine losses , 1935, Electrical Engineering.

[4]  Turgut Meydan,et al.  Errors in the power loss measured in clockwise and anticlockwise rotational magnetisation. Part 1: Mathematical study , 2006 .

[5]  A. Bousbaine A thermometric approach to the determination of iron losses in single phase induction motors , 1999 .

[6]  F. J. Anayi,et al.  Opportunities and Precautions in Measurement of Power Loss in Electrical Steel Laminations Using the Initial Rate of Rise of Temperature Method , 2013, IEEE Transactions on Magnetics.

[7]  Pragasen Pillay,et al.  Consideration of Design and Operation on Rotational Flux Density Distributions in Hydrogenerator Stators , 2015, IEEE Transactions on Energy Conversion.

[8]  A. Moses,et al.  Comparison of flux distribution in three-phase transformer cores assembled from amorphpus material and grain oriented silicon iron , 1989, International Magnetics Conference.

[9]  Jianguo Zhu,et al.  Measurement and Modeling of Rotational Core Losses of Soft Magnetic Materials Used in Electrical Machines: A Review , 2008, IEEE Transactions on Magnetics.

[10]  A. Merkhouf,et al.  Consideration of design and operation on rotational flux density distributions in hydro generator stators , 2014, 2014 International Conference on Electrical Machines (ICEM).

[11]  Fred C. Lee,et al.  New core loss measurement method for high frequency magnetic materials , 2014, 2010 IEEE Energy Conversion Congress and Exposition.

[12]  E. Mulasalihovic,et al.  Rotational Magnetization in Transformer Cores—A Review , 2011, IEEE Transactions on Magnetics.

[13]  Masato Enokizono,et al.  Effect of stator construction of three-phase induction motors on core loss , 2003 .

[14]  J. Sievert,et al.  Two-dimensional magnetic measurements - history and achievements of the workshop , 2011 .

[15]  Measurement of rotational power losses in silicon-Iron sheets using wattmeter method , 1985 .

[16]  Carlo Stefano Ragusa,et al.  Magnetic losses at high flux densities in nonoriented Fe–Si alloys , 2008 .

[17]  Jan Melkebeek,et al.  On the advantages and drawbacks of using digital acquisition systems for the determination of magnetic properties of electrical steel sheet and strip , 1999 .

[18]  Bojan Štumberger,et al.  Unreliable determination of vector B in 2-D SST , 2003 .

[19]  Anthony John Moses,et al.  Importance of rotational losses in rotating machines and transformers , 1992 .

[20]  C. R. Boon,et al.  Alternating and rotational power loss at 50 c/s in 3% silicon-iron sheets , 1965 .

[21]  Helmut Pfützner,et al.  Novel 3-phase excited single sheet tester for rotational magnetization , 1996 .

[22]  G. Diaz,et al.  Characterization of Flux Rotation and of the Ensuing Core Losses in the Stator of Induction Motors , 2008, IEEE Transactions on Energy Conversion.