Cost of Impressed Current Cathodic Protection for Coastal Oregon Bridges
暂无分享,去创建一个
The State of Oregon is using arc-sprayed zinc coatings for anodes in impressed current cathodic protection (ICCP) systems on reinforced concrete coastal bridges. The two lowest bids for four ICCP projects were averaged and converted to 1997 dollars. The total average cost for the ICCP projects was $51.63/ft2 ($555.51/m2) of protected concrete. The cathodic protection part of the ICCP projects average $14.08/ft2 ($151.47/m2), while zinc anode installation cost an average of $7.13/ft2 ($76.67/m2). Oregon's rugged and beautiful coastline is graced with a series of historical arched bridges designed by Conde B. McCullough. McCullough is the internationally recognized architect who designed many of the Oregon Coast Highway (U.S. 101) bridges in the 1920s and 1930s. Many are listed on the National Historic Register. After the expense ($45m) and public outcry associated with the replacement of the historic Alsea Bay Bridge in Waldport, Oregon, the Oregon Department of Transportation began using impressed current cathodic protection (ICCP) to extend the service life of reinforced concrete bridges. Figure 1 visually illustrates the need for such remediation. It shows exposed rebar from underneath the Brush Creek Bridge, which is very representative of the conditions found underneath many coastal Oregon bridges. Four ICCP projects have beenmore » funded, put out for bid, and completed. The four projects, their bid closing dates, and their completion dates are the Cape Creek Bridge (1990- 1992), the Yaquina Bay Bridge south arches (1991-1995), the Depoe Bay Bridge (1993-1997), and the Yaquina Bay Bridge south approach (1995-1997). The Cape Creek, Yaquina Bay, and Depoe Bay Bridges are shown in Figs. 2-4. Other ICCP projects are underway on the Oregon coast. In the ICCP systems, arc-sprayed zinc coatings on the concrete surface are anodes that protect the steel rebar. Accelerated laboratory studies at the Albany Research Center have predicted zinc anode service lives of approximately 27 years based on long-term bond strength measurements.1-3 Experience in California4 has documented zinc anode service lives of over 11 years. Both indicate a substantial savings in project costs compared to bridge replacement. For example, the replacement cost of the arc-sprayed sections of the three Oregon bridges is estimated to be $57m, while the four ICCP projects on those bridges have cost $20m. (The $45m to replace the Alsea Bay Bridge was more than simply the replacement cost--it included expanding the bridge to four lanes and making the bridge ''ICCP ready'' by ensuring electrically continuous rebar).« less