Image-based material decomposition with a general volume constraint for photon-counting CT

Photon-counting CT (PCCT) potentially offers both improved dose efficiency and material decomposition capabilities relative to CT systems using energy integrating detectors. With respect to material decomposition, both projection-based and image-based methods have been proposed, most of which require accurate a priori information regarding the shape of the x-ray spectra and the response of the detectors. Additionally, projection-based methods require access to projection data. These data can be difficult to obtain, since spectra, detector response, and projection data formats are proprietary information. Further, some published image-based, 3-material decomposition methods require a volume conservation assumption, which is often violated in solutions. We have developed an image-based material decomposition method that can overcome those limitations. We introduced a general condition on volume constraint that does not require the volume to be conserved in a mixture. An empirical calibration can be performed with various concentrations of basis materials. The material decomposition method was applied to images acquired from a prototype whole-body PCCT scanner. The results showed good agreement between the estimation and known mass concentration values. Factors affecting the performance of material decomposition, such as energy threshold configuration and volume conservation constraint, were also investigated. Changes in accuracy of the mass concentration estimates were demonstrated for four different energy configurations and when volume conservation was assumed.

[1]  J. Carr Detection and Quantification of Calcified Coronary Plaque With Multidetector-Row CT , 2005 .

[2]  Armando Manduca,et al.  Adaptive nonlocal means filtering based on local noise level for CT denoising. , 2013, Medical physics.

[3]  J. Gomori,et al.  Hepatic iron overload: quantitative MR imaging. , 1991, Radiology.

[4]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[5]  Xin Liu,et al.  Quantitative imaging of chemical composition using dual-energy, dual-source CT , 2008, SPIE Medical Imaging.

[6]  A Malusek,et al.  The potential of dual-energy computed tomography for quantitative decomposition of soft tissues to water, protein and lipid in brachytherapy , 2013, Physics in medicine and biology.

[7]  Thilo Hannemann,et al.  First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT , 2012, Medical Imaging.

[8]  Rafidah Zainon,et al.  Toward quantifying the composition of soft tissues by spectral CT with Medipix3. , 2012, Medical physics.

[9]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[10]  R. Alvarez Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysis. , 2011, Medical physics.

[11]  Shuai Leng,et al.  Quantification of iron in the presence of calcium with dual-energy computed tomography (DECT) in an ex vivo porcine plaque model , 2011, Physics in medicine and biology.

[12]  E. Roessl,et al.  Cramér–Rao lower bound of basis image noise in multiple-energy x-ray imaging , 2009, Physics in medicine and biology.

[13]  Katsuyuki Taguchi,et al.  Material separation in x-ray CT with energy resolved photon-counting detectors , 2011, Medical Imaging.

[14]  L. Garnero,et al.  X-ray dual-energy calibration based on estimated spectral properties of the experimental system , 1998 .