Comparison of cathodal, anodal, and bipolar strength-interval curves with temporary and permanent pacing electrodes.

suMMARY Acute animal experiments indicate that ventricular vulnerability to fibrillation or multiple premature contractions is greater during bipolar or anodal stimulation than with unipolar cathodal (with electrodes of equal cathodal and anodal surface area) because the anodal and bipolar absolute refractory periods are shorter, enabling easier excitation in the vulnerable period. To compare the relative safety of stimulation with various commercial electrodes, strength-interval curves were determined in patients during the initial period after electrode implantation (acute studies) and after a few years of pacing (chronic studies). In 9 of 10 acute studies in patients with permanent bipolar electrodes (anode surface area 4-4 times cathode) and in 9 of 10 chronic studies in patients with bipolar electrodes, the unipolar cathodal and bipolar refractory periods were equal. However, in 7 of 12 patients with temporary bipolar electrodes (equal anodal and cathodal surface areas) and in 2 out of 20 acute and chronic studies in patients with permanent bipolar electrodes, the bipolar refractory periods were significantly shorter than cathodal because of anodal stimulation at the proximal electrode. Under appropriate physiological conditions and competitive pacing, these patients would be more vulnerable to arrhythmias with bipolar stimulation than with unipolar cathodal. To decrease that risk, the anodal surface area should be 5 to 7 times the cathodal, or the anode should be removed from the ventricle, especially for temporary pacing in circumstances of high vulnerability to arrhythmias.

[1]  S. Furman,et al.  Vulnerability of the mildly ischemic ventricle to cathodal, anodal, and bipolar stimulation. , 1977, Circulation research.

[2]  Zipes Dp Electrophysiological mechanisms involved in ventricular fibrillation. , 1975 .

[3]  D. Zipes Electrophysiological Mechanisms Involved in Ventricular Fibrillation , 1975, Circulation.

[4]  S. Furman,et al.  Clinical thresholds of endocardial cardiac stimulation: a long-term study. , 1975, The Journal of surgical research.

[5]  D. Zipes,et al.  Treatment of tachyarrhythmias by pacing. , 1975, Archives of internal medicine.

[6]  T. Preston A new temporary pacing catheter with improved sensing and safety characteristics. , 1974, American heart journal.

[7]  J. Rios,et al.  Temporary transvenous pacemaker therapy: an analysis of complications. , 1973, Chest.

[8]  T. Preston Anodal stimulation as a cause of pacemaker-induced ventricular fibrillation. , 1973, American heart journal.

[9]  O. Roth,et al.  Dangers of pacemakers in acute myocardial infarction. , 1971, Connecticut medicine.

[10]  C. Lippestad,et al.  [Pacemaker-induced arrhythmia]. , 1971, Nordisk medicin.

[11]  J. .. Abildskov,et al.  Fibrillation threshold of a patient with myocardial infarction treated with a fixed-rate pacemaker: case report. , 1970, American heart journal.

[12]  K. Chatterjee,et al.  Fall of endocardial potentials after acute myocardial infarction. , 1970, Lancet.

[13]  A. Castellanos,et al.  Repetitive firing produced by pacemaker stimuli falling after the T wave. , 1970, The American journal of cardiology.

[14]  H. Burchell,et al.  MANAGEMENT OF CARDIAC TACHYARRHYTHMIAS WITH CARDIAC PACEMAKERS , 1969, Annals of the New York Academy of Sciences.

[15]  A. Castellanos,et al.  Systolic and diastolic pacemaker induced repetitive firing in the human heart. Analysis of 23 cases. , 1969, Journal of electrocardiology.

[16]  H. A. Heggtveit,et al.  Electrical pathological obervations on the response of the canine heart to cardiac pacing. , 1968, The British journal of surgery.

[17]  G. Lepage,et al.  Pacemaker-induced repetitive firing: report of two cases. , 1967, Canadian Medical Association journal.

[18]  M. Bilitch,et al.  Ventricular fibrillation and competitive pacing. , 1967, The New England journal of medicine.

[19]  W. R. Schmidt,et al.  Intracavitary cardiac pacing. , 1966, JAMA.

[20]  J. Jude,et al.  Repetitive firing occurring during synchronized electrical stimulation of the heart. , 1966, The Journal of thoracic and cardiovascular surgery.

[21]  H. Falsetti,et al.  VENTRICULAR FIBRILLATION ASSOCIATED WITH TWO FUNCTIONING IMPLANTED CARDIAC PACEMAKERS. , 1965, The American journal of cardiology.

[22]  A. Castellanos,et al.  PACEMAKING ON DEMAND IN AV BLOCK. , 1965, JAMA.

[23]  C. Fisch,et al.  Repetitive Ventricular Arrhythmia Resulting from Artificial Internal Pacemaker , 1964, Circulation.

[24]  S. Pettersson,et al.  Artificial pacemaker for treatment of Adams-Stokes syndrome and slow heart rate☆ , 1963 .

[25]  B. Hoffman,et al.  Anodal excitation of cardiac muscle. , 1957, The American journal of physiology.

[26]  C. Altshuler Excitability of the Heart , 1956 .

[27]  J. Strackee,et al.  The Excitability Cycle of the Dog's Left Ventricle Determined by Anodal, Cathodal, and Bipolar Stimulation , 1956, Circulation research.

[28]  Carl J. Wiggers,et al.  VENTRICULAR FIBRILLATION DUE TO SINGLE, LOCALIZED INDUCTION AND CONDENSER SHOCKS APPLIED DURING THE VULNERABLE PHASE OF VENTRICULAR SYSTOLE , 1940 .

[29]  L. Wiener,et al.  Pacemaker "nonsense". , 1975, American heart journal.

[30]  M. Lanoy,et al.  Fibrillation ventriculaire déclenchée par un pace-maker à rhythme fixe implanté depuis 20 mois. , 1973 .

[31]  N. Picart,et al.  [Ventricular fibrillation induced by a fixed rate pacemaker implanted for 20 months]. , 1973, Acta cardiologica.

[32]  L. Cabrera [Ventricular fibrillation]. , 1956, Neurocirugia.