Semi-automated stereoradiographic upper limb 3D reconstructions using a combined parametric and statistical model: a preliminary study

PurposeQuantitative assessment of 3D clinical indices may be crucial for elbow surgery planning. 3D parametric modeling from bi-planar radiographs was successfully proposed for spine and lower limb clinical investigation as an alternative for CT-scan. The aim of this study was to adapt this method to the upper limb with a preliminary validation.MethodsCT-scan 3D models of humerus, radius and ulna were obtained from 20 cadaveric upper limbs and yielded parametric models made of geometric primitives. Primitives were defined by descriptor parameters (diameters, angles…) and correlations between these descriptors were found. Using these correlations, a semi-automated reconstruction method of humerus using bi-planar radiographs was achieved: a 3D personalized parametric model was built, from which clinical parameters were computed [orientation and projections on bone surface of trochlea sulcus to capitulum (CTS) axis, trochlea sulcus anterior offset and width of distal humeral epiphysis]. This method was evaluated by accuracy compared to CT-scan and reproducibility.ResultsPoints-to-surface mean distance was 0.9 mm (2 RMS = 2.5 mm). For clinical parameters, mean differences were 0.4–1.9 mm and from 1.7° to 2.3°. All parameters except from angle formed by CTS axis and bi-epicondylar axis in transverse plane were reproducible. Reconstruction time was about 5 min.ConclusionsThe presented method provides access to morphological upper limb parameters with very low level of radiation. Preliminary in vitro validation for humerus showed that it is fast and accurate enough to be used in clinical daily practice as an alternative to CT-scan for total elbow arthroplasty pre operative evaluation.

[1]  James A. Johnson,et al.  Surgeon accuracy in the selection of the flexion-extension axis of the elbow: an in vitro study. , 2006, Journal of shoulder and elbow surgery.

[2]  W Skalli,et al.  3D reconstruction of the spine from biplanar X-rays using parametric models based on transversal and longitudinal inferences. , 2009, Medical engineering & physics.

[3]  H E Veeger,et al.  Determining the optimal flexion-extension axis of the elbow in vivo - a study of interobserver and intraobserver reliability. , 2000, Journal of biomechanics.

[4]  David Mitton,et al.  Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity , 2008, Medical & Biological Engineering & Computing.

[5]  James A. Johnson,et al.  Morphologic analysis of the distal humerus with special interest in elbow implant sizing and alignment. , 2007, Journal of shoulder and elbow surgery.

[6]  E. Chao,et al.  A biomechanical study of normal functional elbow motion. , 1981, The Journal of bone and joint surgery. American volume.

[7]  W Skalli,et al.  Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays , 2012, Computer methods in biomechanics and biomedical engineering.

[8]  J.A. De Guise,et al.  Surface reconstruction from planar x-ray images using moving least squares , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Stefano Filippi,et al.  Comparing parametric solid modelling/reconfiguration, global shape modelling and free-form deformation for the generation of 3D digital models of femurs from X-ray images , 2009 .

[10]  A. Lundberg,et al.  Variation in the position and orientation of the elbow flexion axis. , 2003, The Journal of bone and joint surgery. British volume.

[11]  Georges Charpak,et al.  Une nouvelle imagerie Ostéo-Articulaire basse dose en position debout : le système EOS , 2005 .

[12]  E. Berthonnaud,et al.  Three-dimensional in vivo displacements of the shoulder complex from biplanar radiography , 2005, Surgical and Radiologic Anatomy.

[13]  David Mitton,et al.  Fast accurate stereoradiographic 3D-reconstruction of the spine using a combined geometric and statistic model. , 2004, Clinical biomechanics.

[14]  J. London Kinematics of the elbow. , 1981, The Journal of bone and joint surgery. American volume.

[15]  B F Morrey,et al.  Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. , 1995, The Journal of arthroplasty.

[16]  Hubert Labelle,et al.  Diagnostic Imaging of Spinal Deformities: Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager , 2010, Spine.

[18]  D Mitton,et al.  3D reconstruction of the pelvis from bi-planar radiography , 2006, Computer methods in biomechanics and biomedical engineering.