Three-dimensional MR Fingerprinting for Quantitative Breast Imaging.

Purpose To develop a fast three-dimensional method for simultaneous T1 and T2 quantification for breast imaging by using MR fingerprinting. Materials and Methods In this prospective study, variable flip angles and magnetization preparation modules were applied to acquire MR fingerprinting data for each partition of a three-dimensional data set. A fast postprocessing method was implemented by using singular value decomposition. The proposed technique was first validated in phantoms and then applied to 15 healthy female participants (mean age, 24.2 years ± 5.1 [standard deviation]; range, 18-35 years) and 14 female participants with breast cancer (mean age, 55.4 years ± 8.8; range, 39-66 years) between March 2016 and April 2018. The sensitivity of the method to B1 field inhomogeneity was also evaluated by using the Bloch-Siegert method. Results Phantom results showed that accurate and volumetric T1 and T2 quantification was achieved by using the proposed technique. The acquisition time for three-dimensional quantitative maps with a spatial resolution of 1.6 × 1.6 × 3 mm3 was approximately 6 minutes. For healthy participants, averaged T1 and T2 relaxation times for fibroglandular tissues at 3.0 T were 1256 msec ± 171 and 46 msec ± 7, respectively. Compared with normal breast tissues, higher T2 relaxation time (68 msec ± 13) was observed in invasive ductal carcinoma (P < .001), whereas no statistical difference was found in T1 relaxation time (1183 msec ± 256; P = .37). Conclusion A method was developed for breast imaging by using the MR fingerprinting technique, which allows simultaneous and volumetric quantification of T1 and T2 relaxation times for breast tissues. © RSNA, 2018 Online supplemental material is available for this article.

[1]  Nicholas R Zwart,et al.  Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring. , 2017, Magnetic resonance imaging.

[2]  Jesse I. Hamilton,et al.  MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density , 2017, Magnetic resonance in medicine.

[3]  Yong Chen,et al.  MR Fingerprinting for Rapid Quantitative Abdominal Imaging. , 2016, Radiology.

[4]  Woo Kyung Moon,et al.  Diffusion-weighted MR imaging: pretreatment prediction of response to neoadjuvant chemotherapy in patients with breast cancer. , 2010, Radiology.

[5]  P. Bolan Magnetic resonance spectroscopy of the breast: current status. , 2013, Magnetic resonance imaging clinics of North America.

[6]  Huanzhou Yu,et al.  Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL , 2006, Journal of magnetic resonance imaging : JMRI.

[7]  Fiona J Gilbert,et al.  B1 transmission‐field inhomogeneity and enhancement ratio errors in dynamic contrast‐enhanced MRI (DCE‐MRI) of the breast at 3T , 2010, Journal of magnetic resonance imaging : JMRI.

[8]  A. C. Santos,et al.  Magnetization transfer ratio as a predictor of malignancy in breast lesions: Preliminary results , 2008, Magnetic resonance in medicine.

[9]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[10]  R. Powell,et al.  Magnetic resonance imaging in the diagnosis of breast disease: use of transverse relaxation times. , 1984, Radiology.

[11]  Can diffusion-weighted MR imaging be used as a biomarker for predicting response to neoadjuvant chemotherapy in patients with locally advanced breast cancer? , 2011, Radiology.

[12]  C. Kuhl Current status of breast MR imaging. Part 2. Clinical applications. , 2007, Radiology.

[13]  W. Peng,et al.  Changes of T2 Relaxation Time From Neoadjuvant Chemotherapy in Breast Cancer Lesions , 2016, Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society.

[14]  R. J. Ross,et al.  Nuclear magnetic resonance imaging and evaluation of human breast tissue: preliminary clinical trials. , 1982, Radiology.

[15]  Ralf-Dieter Hilgers,et al.  Abbreviated breast magnetic resonance imaging (MRI): first postcontrast subtracted images and maximum-intensity projection-a novel approach to breast cancer screening with MRI. , 2014, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[16]  Wolfgang Bogner,et al.  Quantitative Sodium MR Imaging at 7 T: Initial Results and Comparison with Diffusion-weighted Imaging in Patients with Breast Tumors. , 2016, Radiology.

[17]  S. E. el Yousef,et al.  Transverse Relaxation Time Values in MR Imaging of Normal Breast During Menstrual Cycle , 1986, Journal of computer assisted tomography.

[18]  René M. Botnar,et al.  Comparison of fat suppression strategies in 3D spiral coronary magnetic resonance angiography , 2002, Journal of magnetic resonance imaging : JMRI.

[19]  Yun Jiang,et al.  SVD Compression for Magnetic Resonance Fingerprinting in the Time Domain , 2014, IEEE Transactions on Medical Imaging.

[20]  Vikas Gulani,et al.  Development of a Combined MR Fingerprinting and Diffusion Examination for Prostate Cancer. , 2017, Radiology.

[21]  L. Turnbull,et al.  Neoadjuvant chemotherapy in breast cancer: early response prediction with quantitative MR imaging and spectroscopy , 2006, British Journal of Cancer.

[22]  Vikas Gulani,et al.  Bayesian estimation of multicomponent relaxation parameters in magnetic resonance fingerprinting , 2018, Magnetic resonance in medicine.

[23]  D. Sodickson,et al.  Intravoxel incoherent motion imaging of tumor microenvironment in locally advanced breast cancer , 2011, Magnetic resonance in medicine.

[24]  Weijun Peng,et al.  Role of quantitative analysis of T2 relaxation time in differentiating benign from malignant breast lesions , 2018, The Journal of international medical research.

[25]  M. Pickles,et al.  Lesion T(2) relaxation times and volumes predict the response of malignant breast lesions to neoadjuvant chemotherapy. , 2008, Magnetic resonance imaging.

[26]  Albert Macovski,et al.  Coronary Angiography with Magnetization‐Prepared T2 Contrast , 1995, Magnetic resonance in medicine.

[27]  M. Komu,et al.  Relaxation Times of Normal Breast Tissues , 1994, Acta radiologica.

[28]  Daniel B Kopans,et al.  Physiologic Changes in Breast Magnetic Resonance Imaging during the Menstrual Cycle: Perfusion Imaging, Signal Enhancement, and Influence of the T1 Relaxation Time of Breast Tissue , 2005, The breast journal.