Design and validation of an instrument package designed to increase the reliability of ankle range of motion measurements.

OBJECTIVE To validate a novel device termed the equinometer, which is designed to accurately measure ankle dorsiflexion. DESIGN Test retest reliability analysis using serial measurements of dorsiflexion endpoint in a group of normal individuals. SETTING Motion analysis laboratory. PARTICIPANTS Ten healthy individuals. PRIMARY OUTCOME MEASURE The mean and standard deviation of the absolute difference in dorsiflexion endpoint for the group. RESULTS The mean absolute change in dorsiflexion endpoint for the group was 0.45 degrees with a standard deviation of 0.43 degrees. CONCLUSIONS With the use of the device described, the mean change in dorsiflexion endpoint was well within acceptable clinical limits. The reliability of measurements obtained with the equinometer exceeds that which has been published with other techniques and devices.

[1]  J. Ekstrand,et al.  Lower extremity goniometric measurements: a study to determine their reliability. , 1982, Archives of physical medicine and rehabilitation.

[2]  J. M. Rothstein,et al.  Goniometric reliability in a clinical setting. Subtalar and ankle joint measurements. , 1988, Physical therapy.

[3]  S L Wolf,et al.  Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. , 1988, Physical therapy.

[4]  J A Hanson,et al.  The influence of experience on the reliability of goniometric and visual measurement of forefoot position. , 1997, The Journal of orthopaedic and sports physical therapy.

[5]  L. Otago,et al.  Instrumentation considerations of a clinical and a computerized technique for the measurement of foot angles. , 1998, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.

[6]  F. A. Hellebrandt,et al.  The Measurement of Joint Motion: Part III—Reliability of Goniometry , 1949 .

[7]  J. M. Rothstein,et al.  Subtalar and Ankle Joint Measurements , 1987 .

[8]  B. Ashton,et al.  Reliability of Goniometric Measurements of Hip Motion in Spastic Cerebral Palsy , 1978, Developmental medicine and child neurology.

[9]  Mayerson Nh,et al.  Goniometric measurement reliability in physical medicine. , 1984 .

[10]  A. Veves,et al.  Relationship of Limited Joint Mobility to Abnormal Foot Pressures and Diabetic Foot Ulceration , 1991, Diabetes Care.

[11]  K. Rome,et al.  A Reliability Study of the Universal Goniometer, Fluid Goniometer, and Electrogoniometer for the Measurement of Ankle Dorsiflexion , 1996, Foot & ankle international.

[12]  J. Youdas,et al.  Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical setting. , 1993, Archives of physical medicine and rehabilitation.

[13]  M T Gross,et al.  Intraexaminer reliability, interexaminer reliability, and mean values for nine lower extremity skeletal measures in healthy naval midshipmen. , 1997, The Journal of orthopaedic and sports physical therapy.

[14]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[15]  M. Province,et al.  Reliability of goniometric measurements in patients with Duchenne muscular dystrophy. , 1985, Physical therapy.

[16]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Shoulder measurements. , 1987, Physical therapy.