Experimental modal identification of an existent earthen residential building

The paper presents the preliminary round of in-situ experimental tests carried out at “Hotel Comercio”, a historical construction located at the historical centre of Lima (capital of Peru). The building is a three story republican-type construction built at 19 th Century with composite structure of Adobe and “Quincha”. The experimental works consisted on Operational Modal Analysis (OMA) tests aiming at identifying the dynamic characteristics of the building using the environmental noise as source of excitation. The severe damage at the Hotel, as well as its complex boundary conditions made the dynamic identification process hard to carry out. The experimental results showed coupled global and local modes. The expected different behaviour of the Quincha panels and the Adobe in terms of flexibility was also verified. The Finite element model of the building was implemented and a preliminary numerical model updating was carried out. The modal comparison of the numerical and experimental results evidenced that few modes were accurately assessed by the analytical approach. An important contribution of the paper is the introduction of OMA as a tool for better understanding the structural behaviour which may also allow assessing the real damage condition of the buildings.

[1]  Keith Worden,et al.  An introduction to structural health monitoring , 2007, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[2]  Elsa Caetano,et al.  FROM INPUT-OUTPUT TO OUTPUT-ONLY MODAL IDENTIFICATION OF CIVIL ENGINEERING STRUCTURES , 2005 .

[3]  Wei-Xin Ren,et al.  Dynamic and seismic performance of old multi-tiered temples in Nepal , 2003 .

[4]  Charles F. Walker Shaky Colonialism: The 1746 Earthquake-Tsunami in Lima, Peru, and Its Long Aftermath , 2008 .

[5]  Aníbal Costa,et al.  Caracterização dinâmica e análise sísmica da Ponte da Lagoncinha , 2004 .

[6]  Patrick Bukenya Ambient vibration testing of concrete dams , 2011 .

[7]  Carmelo Gentile,et al.  Dynamic-based F.E. model updating to evaluate damage in masonry towers , 2004 .

[8]  Filippo Casarin,et al.  DYNAMIC IDENTIFICATION OF S. MARIA ASSUNTA CATHEDRAL, REGGIO EMILIA, ITALY , 2007 .

[9]  Paulo B. Lourenço,et al.  Investigations techniques carried out on the Qutb Minar, New Delhi, India , 2006 .

[10]  S. Lagomarsino,et al.  Ambient Vibration Testing at N. Sra. do Carmo Church, Prelimi-nary Results , 2013 .

[11]  José Gálvez,et al.  Calles de Lima y meses del año , 1943 .

[12]  Carlos Rebelo MODAL IDENTIFICATION OF THE COIMBRA UNIVERSITY TOWER , 2007 .

[13]  Salvador Ivorra A MASONRY BELL-TOWER ASSESSMENT BY MODAL TESTING , 2007 .

[14]  Thomas Schmidt DYNAMIC BEHAVIOR OF TWIN BELL TOWERS , 2007 .

[15]  Paulo B. Lourenço,et al.  Dynamic Identification and FE Updating of S. Torcato Church, Portugal , 2011 .

[16]  Paulo B. Lourenço,et al.  Operational modal analysis of historical constructions using commercial wireless platforms , 2011 .