Experimental validation of tangential resolution improvement in photoacoustic tomography using modified delay-and-sum reconstruction algorithm

Abstract. For a circular scanning geometry in photoacoustic tomography, the axial/radial resolution is spatially invariant and is not affected by the ultrasound transducer (UST, detector) aperture. However, the tangential resolution is dependent on the detector aperture size and it varies spatially. Many techniques were proposed to improve the tangential resolution, such as attaching a concave lens in front of the nonfocused transducer or using a virtual point detector. Both of these methods have difficulties. Therefore, a modified delay-and-sum reconstruction algorithm has been proposed which can be used together with a standard ultrasound detector (nonfocused) to improve the tangential resolution. In this work, we validate the modified delay-and-sum algorithm experimentally for both flat and cylindrically focused USTs. More than threefold improvement in tangential resolution is observed. It is also shown that the object shape is recovered with this modified algorithm, which is very helpful for diagnosis and treatment purposes.

[1]  Minghua Xu,et al.  Time-domain reconstruction for thermoacoustic tomography in a spherical geometry , 2002, IEEE Transactions on Medical Imaging.

[2]  Lihong V. Wang,et al.  Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs , 2012, Science.

[3]  M. Fabiani,et al.  Three-dimensional laser-induced photoacoustic tomography of mouse brain with the skin and skull intact , 2003 .

[4]  W Steenbergen,et al.  Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging. , 2014, Optics express.

[5]  Minghua Xu,et al.  Pulsed-microwave-induced thermoacoustic tomography: filtered backprojection in a circular measurement configuration. , 2002, Medical physics.

[6]  S. Jacques,et al.  Iterative reconstruction algorithm for optoacoustic imaging. , 2002, The Journal of the Acoustical Society of America.

[7]  Manojit Pramanik,et al.  Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography. , 2014, Journal of the Optical Society of America. A, Optics, image science, and vision.

[8]  Vasilis Ntziachristos,et al.  Modeling the shape of cylindrically focused transducers in three-dimensional optoacoustic tomography , 2013, Journal of biomedical optics.

[9]  Manojit Pramanik,et al.  Design and evaluation of a novel breast cancer detection system combining both thermoacoustic (TA) and photoacoustic (PA) tomography. , 2008, Medical physics.

[10]  Minghua Xu,et al.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[11]  Xosé Luís Deán-Ben,et al.  Expediting model-based optoacoustic reconstructions with tomographic symmetries. , 2013, Medical physics.

[12]  K. P. Köstli,et al.  Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response. , 2003, Applied optics.

[13]  Manojit Pramanik,et al.  In vivo carbon nanotube-enhanced non-invasive photoacoustic mapping of the sentinel lymph node , 2009, Physics in medicine and biology.

[14]  Lihong V. Wang,et al.  Photoacoustic tomography of the mouse cerebral cortex with a high-numerical-aperture-based virtual point detector. , 2009, Journal of biomedical optics.

[15]  Manojit Pramanik,et al.  Molecular photoacoustic imaging of angiogenesis with integrin‐targeted gold nanobeacons , 2011, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[16]  Manojit Pramanik,et al.  Tangential resolution improvement in thermoacoustic and photoacoustic tomography using a negative acoustic lens. , 2009, Journal of biomedical optics.

[17]  Manojit Pramanik,et al.  Sentinel lymph nodes in the rat: noninvasive photoacoustic and US imaging with a clinical US system. , 2010, Radiology.

[18]  Manojit Pramanik,et al.  Least squares QR-based decomposition provides an efficient way of computing optimal regularization parameter in photoacoustic tomography , 2013, Journal of biomedical optics.

[19]  Balaji Sitharaman,et al.  Multimodal ultrasound-photoacoustic imaging of tissue engineering scaffolds and blood oxygen saturation in and around the scaffolds. , 2014, Tissue engineering. Part C, Methods.

[20]  T. V. van Leeuwen,et al.  Design and evaluation of a laboratory prototype system for 3D photoacoustic full breast tomography. , 2013, Biomedical optics express.

[21]  Tianheng Wang,et al.  Characterization of ovarian tissue based on quantitative analysis of photoacoustic microscopy images. , 2013, Biomedical optics express.

[22]  Manojit Pramanik,et al.  Near infrared photoacoustic detection of sentinel lymph nodes with gold nanobeacons. , 2010, Biomaterials.

[23]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[24]  Paul Kumar Upputuri,et al.  Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system. , 2015, Biomedical optics express.

[25]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[26]  Mark A. Anastasio,et al.  Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography With Acoustically Inhomogeneous Media , 2013, IEEE Transactions on Medical Imaging.

[27]  Markus Haltmeier,et al.  Spatial resolution in photoacoustic tomography: effects of detector size and detector bandwidth , 2010 .

[28]  Lihong V. Wang,et al.  Photoacoustic imaging and characterization of the microvasculature. , 2010, Journal of biomedical optics.

[29]  Lihong V. Wang,et al.  Thermoacoustic and photoacoustic sensing of temperature. , 2009, Journal of biomedical optics.

[30]  Lihong V Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography , 2005, SPIE BiOS.

[31]  Xin Cai,et al.  Photoacoustic tomography of foreign bodies in soft biological tissue. , 2011, Journal of biomedical optics.

[32]  Lihong V. Wang,et al.  High-numerical-aperture-based virtual point detectors for photoacoustic tomography. , 2008, Applied physics letters.

[33]  Manojit Pramanik,et al.  Basis pursuit deconvolution for improving model-based reconstructed images in photoacoustic tomography. , 2014, Biomedical optics express.