Decoupling dehumidification and cooling for energy saving and desirable space air conditions in hot and humid Hong Kong

Abstract The combined use of dedicated outdoor air ventilation (DV) and dry cooling (DC) air-conditioning system to decouple sensible and latent cooling for desirable space air conditions, better indoor air quality, and energy efficiency is proposed for hot and humid climates like Hong Kong. In this study, the performance and energy saving potential of DCDV system in comparison to conventional systems (constant air volume (CAV) system with and without reheat) for air conditioning of a typical office building in Hong Kong are evaluated. Through hour-by-hour simulations, using actual equipment performance data and realistic building and system characteristics, the cooling load profile, resultant indoor air conditions, condensation at the DC coil, and energy consumptions are calculated and analyzed. The results indicate that with the use of DCDV system, the desirable indoor conditions could be achieved and the annual energy use could be reduced by 54% over CAV system with reheat. The condensate-free characteristic at the DC coil to reduce risk of catching disease could also be realized.

[1]  Jianlei Niu,et al.  Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates , 2002 .

[2]  W. L. Lee,et al.  Evaluating the use heat pipe for dedicated ventilation of office buildings in Hong Kong , 2011 .

[3]  W. L. Lee,et al.  Combined space cooling and water heating system for Hong Kong residences , 2010 .

[4]  Michael J. Brandemuehl,et al.  Optimization of air-conditioning system operating strategies for hot and humid climates , 2008 .

[5]  W. L. Lee,et al.  Developing a simplified model for evaluating chiller-system configurations , 2007 .

[6]  Stanley A. Mumma,et al.  Designing Dedicated Outdoor Air Systems , 2001 .

[7]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[8]  Francis W.H. Yik,et al.  Energy performance criteria in the Hong Kong building environmental assessment method , 1998 .

[9]  Guoqiang Zhang,et al.  A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification , 2007 .

[10]  Moh’d A. Al-Nimr,et al.  A novel summer air conditioning system , 2002 .

[11]  Jianlei Niu,et al.  Indoor humidity behaviors associated with decoupled cooling in hot and humid climates , 2003 .

[12]  Andrea Gasparella,et al.  New ideas for energy utilisation in combined heat and power with cooling: I. Principles , 1997 .

[13]  John Murphy Dehumidification performance of HVAC systems , 2002 .

[14]  S. Jain,et al.  Experimental performance of a liquid desiccant dehumidification system under tropical climates , 2011 .

[15]  Joseph C. Lam,et al.  Energy analysis of commercial buildings in subtropical climates , 2000 .

[16]  John Burnett,et al.  Mechanistic model of centrifugal chillers for HVAC system dynamics simulation , 2000 .

[17]  Donal Finn,et al.  Indirect evaporative cooling potential in air-water systems in temperate climates , 2003 .

[18]  Lew Harriman,et al.  Humidity Control Design Guide for Commercial and Institutional Buildings , 2001 .

[19]  Dongsheng Zhu,et al.  Thermodynamic modeling of a novel air dehumidification system , 2005, Energy and Buildings.

[20]  M. M. Ardehali,et al.  Proof of concept modeling of energy transfer mechanisms for radiant conditioning panels , 2004 .

[21]  S. Chirarattananon,et al.  An experimental investigation of application of radiant cooling in hot humid climate , 2006 .

[22]  Refrigerating,et al.  Ventilation for acceptable indoor air quality : ANSI/ASHRAE Standard 62.1-2013 , 2013 .

[23]  Andrea Gasparella,et al.  New ideas for energy utilisation in combined heat and power with cooling: II. Applications , 1997 .

[24]  K. F. Fong,et al.  Solar hybrid cooling system for high-tech offices in subtropical climate – Radiant cooling by absorption refrigeration and desiccant dehumidification , 2011 .

[25]  Jianlei Niu,et al.  Performance of cooled-ceiling operating with MPCM slurry , 2009 .

[26]  John Z. Lin,et al.  Generation of a typical meteorological year for Hong Kong , 2006 .

[27]  Jianlei Niu,et al.  ENERGY SAVING POSSIBILITIES WITH COOLED-CEILING SYSTEMS , 1995 .

[28]  Corina Stetiu,et al.  Energy and peak power savings potential of radiant cooling systems in US commercial buildings , 1999 .

[29]  Toshiaki Omori,et al.  Thermal comfort and energy consumption of the radiant ceiling panel system.: Comparison with the conventional all-air system , 1999 .

[30]  Omar M. Al-Rabghi,et al.  A survey of energy efficient strategies for effective air conditioning , 2004 .

[31]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[32]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[33]  Kamel Ghali Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut , 2008 .

[34]  Kelvin K. W. Yau,et al.  A study of domestic energy usage patterns in Hong Kong , 2003 .