Hysteresis measurements of remanent polarization and coercive field in polymers

An experimental method is described which allows estimation of remanent polarization and coercive field without assuming functional forms for the capacitive and electrical resistance terms. The method can be used to measure polarization in specimens with voltage‐dependent conductivity (often arising from the presence of ions in the specimens), voltage‐dependent capacitance, and significant amounts of space charge. It consists of: (1) performing bipolar current/voltage hysteresis loops to allow a steady state of remanent polarization and space charge to build up in the specimen, and (2) following a bipolar loop with two or more unipolar loops in which the polarization changes in the first unipolar loop. Both sinusoidal and linear time‐dependent applied voltages may be used. Automatic data processing of hysteresis loops is described for cases in which specimen behavior may be considered to be ideal.

[1]  C. B. Sawyer,et al.  Rochelle Salt as a Dielectric , 1930 .

[2]  S. Roth,et al.  Room Temperature Poling of Poly(Vinylidene Fluoride) with Deposited Metal Electrodes. , 1979, Journal of research of the National Bureau of Standards.

[3]  J. Scheinbeim,et al.  Effect of annealing on the ferroelectric behavior of nylon - 11 and nylon - 7 , 1991 .

[4]  J. Herbert,et al.  The Applications of Ferroelectric Polymers , 1988 .

[5]  Measuring hysteresis loops of ferroelectric polymers using the constant charging current corona triode , 1991 .

[6]  A. S. DeReggi,et al.  Effects of space charge on the poling of ferroelectric polymers , 1987 .

[7]  Andrew J. Lovinger,et al.  Crystalline forms in a copolymer of vinylidene fluoride and trifluoroethylene (52/48 mol %) , 1982 .

[8]  H. Kawai,et al.  The Piezoelectricity of Poly (vinylidene Fluoride) , 1969 .

[9]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[10]  S. Fedosov Deep Trapping of Injected Carriers in Ferroelectric Polymer , 1989, September 16.

[11]  F. Bauer,et al.  PVF2 polymers: Ferroelectric polarization and piezoelectric properties under dynamic pressure and shock wave action , 1983 .

[12]  H. Diamant,et al.  Bridge for Accurate Measurement of Ferroelectric Hysteresis , 1957 .

[13]  J. Scheinbeim,et al.  Ferroelectric Polarization Switching in Nylon 11 , 1991 .

[14]  Y. Wada,et al.  Effect of space charge on polarization reversal in a copolymer of vinylidene fluoride and trifluoroethylene , 1988 .