Dynamic and Static Magnetic Resonance Angiography of the Supra-aortic Vessels at 3.0 T: Intraindividual Comparison of Gadobutrol, Gadobenate Dimeglumine, and Gadoterate Meglumine at Equimolar Dose

PurposeThe purpose of this study was the intraindividual comparison of a 1.0 M and two 0.5 M gadolinium-based contrast agents (GBCA) using equimolar dosing in dynamic and static magnetic resonance angiography (MRA) of the supra-aortic vessels. Materials and MethodsIn this institutional review board–approved study, a total of 20 healthy volunteers (mean ± SD age, 29 ± 6 years) underwent 3 consecutive supra-aortic MRA examinations on a 3.0 T magnetic resonance system. The order of GBCA (Gadobutrol, Gadobenate dimeglumine, and Gadoterate meglumine) was randomized with a minimum interval of 48 hours between the examinations. Before each examination and 45 minutes after each examination, circulatory parameters were recorded. Total GBCA dose per MRA examination was 0.1 mmol/kg with a 0.03 mmol/kg and 0.07 mmol/kg split for dynamic and static MRA, respectively, injected at a rate of 2 mL/s. Two blinded readers qualitatively assessed static MRA data sets independently using pairwise rankings (superior, inferior, and equal). In addition, quantitative analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) evaluation as well as vessel sharpness analysis of static MRA using an in-house–developed semiautomated tool. Dynamic MRA was evaluated for maximal SNR. Statistical analysis was performed using the Cohen &kgr;, the Wilcoxon rank sum tests, and mixed effects models. ResultsNo significant differences of hemodynamic parameters were observed. In static MRA, Gadobutrol was rated superior to Gadoterate meglumine (P < 0.05) and equal to Gadobenate dimeglumine (P = 0.06) with good to excellent reader agreement (&kgr;, 0.66–0.83). In static MRA, SNR was significantly higher using 1.0 M Gadobutrol as compared with either 0.5 M agent (P < 0.05 and P < 0.05) and CNR was significantly higher as compared with Gadoterate meglumine (P < 0.05), whereas CNR values of Gadobutrol data sets were not significantly different as compared with Gadobenate dimeglumine (P = 0.13). Differences in CNR between Gadobenate dimeglumine and Gadoterate meglumine were not significant (P = 0.78). Differences in vessel sharpness between the different GBCAs were also not significant (P > 0.05). Maximal SNR in dynamic MRA using Gadobutrol was significantly higher than both comparators at the level of the proximal and distal internal carotid artery (P < 0.05 and P < 0.05; P < 0.05 and P < 0.05). ConclusionsAt equimolar doses, 1.0 M Gadobutrol demonstrates higher SNR/CNR than do Gadobenate dimeglumine and Gadoterate meglumine, with superior image quality as compared with Gadoterate meglumine for dynamic and static carotid MRA. Despite the shortened bolus with Gadobutrol, no blurring of vessel edges was observed.

[1]  F. Zaccagna,et al.  Investigation of the Longitudinal Relaxation Rate of Blood After Gadobenate Dimeglumine Administration: Sequence Optimization, Dynamic Acquisition, and Clinical Impact for Contrast-Enhanced MR Angiography of the Carotid Arteries , 2011, Investigative radiology.

[2]  Safety and effectiveness of single- versus triple-dose gadodiamide injection- enhanced MR angiography of the abdomen: a phase III double-blind multicenter study. , 2001, Radiology.

[3]  J. Finn,et al.  3.0 Tesla High Spatial Resolution Contrast-Enhanced Magnetic Resonance Angiography (CE-MRA) of the Pulmonary Circulation: Initial Experience With a 32-Channel Phased Array Coil Using a High Relaxivity Contrast Agent , 2007, Investigative radiology.

[4]  V. Runge,et al.  MR angiography of carotid artery aneurysms in a porcine model at 3 tesla: Comparison of two different macrocyclic gadolinium chelates and of dynamic and conventional techniques , 2012, Journal of magnetic resonance imaging : JMRI.

[5]  F. Zaccagna,et al.  High-Resolution Steady State Magnetic Resonance Angiography of the Carotid Arteries: Are Intravascular Agents Necessary?: Feasibility and Preliminary Experience With Gadobenate Dimeglumine , 2009, Investigative radiology.

[6]  G Schneider,et al.  Does Higher Gadolinium Concentration Play a Role in the Morphologic Assessment of Brain Tumors? Results of a Multicenter Intraindividual Crossover Comparison of Gadobutrol versus Gadobenate Dimeglumine (the MERIT Study) , 2012, American Journal of Neuroradiology.

[7]  G. Schroth,et al.  Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography. , 2002, AJNR. American journal of neuroradiology.

[8]  J Paul Finn,et al.  High Spatial-Resolution CE-MRA of the Carotid Circulation With Parallel Imaging: Comparison of Image Quality Between 2 Different Acceleration Factors at 3.0 Tesla , 2006, Investigative radiology.

[9]  A. Huppertz,et al.  Gadobutrol, a highly concentrated MR imaging contrast agent: its physicochemical characteristics and the basis for its use in contrast-enhanced MR angiography and in perfusion imaging , 2004, European radiology.

[10]  S. Schoenberg,et al.  High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience. , 2006, Radiology.

[11]  S. Schoenberg,et al.  Effects of injection rate and dose on image quality in time-resolved magnetic resonance angiography (MRA) by using 1.0M contrast agents , 2007, European Radiology.

[12]  M. Essig,et al.  Intraindividual Comparison of Gadobenate Dimeglumine and Gadobutrol for Cerebral Magnetic Resonance Perfusion Imaging at 1.5 T , 2006, Investigative radiology.

[13]  K. Reddy,et al.  Cardiovascular disease in non-Western countries. , 2004, The New England journal of medicine.

[14]  S. Schoenberg,et al.  Magnetic Resonance Evaluation of Renal Artery Stenosis in a Swine Model: Performance of Low-Dose Gadobutrol Versus Gadoterate Meglumine in Comparison With Digital Subtraction Intra-Arterial Catheter Angiography , 2012, Investigative radiology.

[15]  F. S. Pereles,et al.  Three-Dimensional Breathhold Magnetization-Prepared TrueFISP: A Pilot Study for Magnetic Resonance Imaging of the Coronary Artery Disease , 2007, Investigative radiology.

[16]  Joseph Whitley INVESTIGATIVE RADIOLOGY , 1982 .

[17]  V. Ajay,et al.  Global cardiovascular disease research survey. , 2007, Journal of the American College of Cardiology.

[18]  G. Scotti,et al.  Carotid artery stenosis: intraindividual correlations of 3D time-of-flight MR angiography, contrast-enhanced MR angiography, conventional DSA, and rotational angiography for detection and grading. , 2005, Radiology.

[19]  J. Mintorovitch,et al.  Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths , 2005, Investigative radiology.

[20]  M. Reiser,et al.  Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques , 2011, European Radiology.

[21]  R. Scotti,et al.  Detection of cerebral metastases on magnetic resonance imaging: intraindividual comparison of gadobutrol with gadopentetate dimeglumine , 2009, Acta radiologica.

[22]  V. Runge,et al.  MR angiography of the renal arteries: intraindividual comparison of double-dose contrast enhancement at 1.5 T with standard dose at 3 T. , 2008, AJR. American journal of roentgenology.

[23]  M. Port,et al.  How to Compare the Efficiency of Albumin-Bound and Nonalbumin-Bound Contrast Agents In Vivo: The Concept of Dynamic Relaxivity , 2005, Investigative radiology.

[24]  S. Yusuf,et al.  Emerging epidemic of cardiovascular disease in developing countries. , 1999, Circulation.

[25]  J. Heverhagen,et al.  Dose comparison of single‐ vs. double‐dose in contrast‐enhanced magnetic resonance angiography of the carotid arteries: Intraindividual cross‐over blinded trial using Gd‐DTPA , 2007, Journal of magnetic resonance imaging : JMRI.

[26]  F. Schick,et al.  Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in Human Blood Plasma at 0.2, 1.5, and 3 Tesla , 2006, Investigative radiology.

[27]  C. Claussen,et al.  Low-dose, time-resolved, contrast-enhanced 3D MR angiography in the assessment of the abdominal aorta and its major branches at 3 Tesla. , 2010, Academic radiology.

[28]  J. Le Bas,et al.  In Vivo Measurement of Gadolinium Concentration in a Rat Glioma Model by Monochromatic Quantitative Computed Tomography: Comparison Between Gadopentetate Dimeglumine and Gadobutrol , 2004, Investigative radiology.

[29]  R. Felix,et al.  [Phantom measurements of spatial resolution and the partial-volume-effect in computer tomography (author's transl)]. , 1978, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[30]  E. Larsson,et al.  Carotid artery stenosis: contrast-enhanced MR angiography with two different scan times compared with digital subtraction angiography , 2002, Neuroradiology.

[31]  J. Heverhagen,et al.  Prospective comparison of image quality and diagnostic accuracy of 0.5 molar gadobenate dimeglumine and 1.0 molar gadobutrol in contrast‐enhanced run‐off magnetic resonance angiography of the lower extremities , 2010, Journal of magnetic resonance imaging : JMRI.

[32]  S. Schoenberg,et al.  High-Resolution Magnetic Resonance Angiography of the Lower Extremities With a Dedicated 36-Element Matrix Coil at 3 Tesla , 2007, Investigative radiology.

[33]  M. Hellmich,et al.  Feasibility of Peripheral Contrast-Enhanced Magnetic Resonance Angiography at 3.0 Tesla With a Hybrid Technique: Comparison With Digital Subtraction Angiography , 2008, Investigative radiology.

[34]  H. Thomsen Nephrogenic systemic fibrosis: a serious late adverse reaction to gadodiamide , 2006, European Radiology.

[35]  B. Wintersperger,et al.  Brain MRI with single-dose (0.1 mmol/kg) Gadobutrol at 1.5 T and 3 T: comparison with 0.15 mmol/kg Gadoterate meglumine. , 2010, AJR. American journal of roentgenology.

[36]  S. Schoenberg,et al.  Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters , 2007, Journal of magnetic resonance imaging : JMRI.

[37]  James C Carr,et al.  Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution--initial results. , 2002, Radiology.

[38]  N. Anzalone Comparative Studies of Different Gadolinium Agents in Brain Tumors: Differences between Gadolinium Chelates and Their Possible Influence on Imaging Features , 2010, American Journal of Neuroradiology.

[39]  U. Klose,et al.  Intra-individual Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine for Contrast-Enhanced Magnetic Resonance Angiography of the Supraaortic Vessels at 3 Tesla , 2008, Investigative radiology.

[40]  D. Hadizadeh,et al.  Simultaneous MR arteriography and venography with blood pool contrast agent detects deep venous thrombosis in suspected arterial disease. , 2012, AJR. American journal of roentgenology.

[41]  M. Reiser,et al.  Peripheral Magnetic Resonance Angiography (MRA) With Continuous Table Movement at 3.0 T: Initial Experience Compared With Step-by-Step MRA , 2008, Investigative radiology.

[42]  E. Merkle,et al.  Contrast-Enhanced Magnetic Resonance Angiography: First-Pass Arterial Enhancement as a Function of Gadolinium-Chelate Concentration, and the Saline Chaser Volume and Injection Rate , 2012, Investigative radiology.

[43]  René M. Botnar,et al.  Flow Targeted 3D Steady-State Free-Precession Coronary MR Angiography: Comparison of Three Different Imaging Approaches , 2009, Investigative radiology.

[44]  J. Finn,et al.  Ultra-Low-Dose, Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of the Carotid Arteries at 3.0 Tesla , 2009, Investigative radiology.