Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions.

BACKGROUND Electromagnetic navigation bronchoscopy (ENB) with biopsy under fluoroscopic guidance has enhanced the yield of flexible bronchoscopy in the diagnosis of peripheral lung lesions. However, the accuracy of ENB navigation suggests that the addition of fluoroscopy is redundant. OBJECTIVES Data were prospectively collected to determine the yield of ENB without fluoroscopy in the diagnosis of peripheral lung lesions. METHOD ENB was performed via flexible bronchoscopy (superDimension/Bronchus system; superDimension Inc; Plymouth, MN). Biopsy specimens were obtained through the extended working channel after navigation. Fluoroscopy was not utilized, but post-transbronchial biopsy chest radiographs were obtained to exclude pneumothorax. The primary end point was diagnostic yield, and the secondary end points were navigation accuracy, procedure duration, and safety. Analysis by lobar distribution was also performed to assess performance in different lobes of the lung. RESULTS Ninety-two peripheral lung lesions were biopsied in the 89 subjects. The diagnostic yield of ENB was 67%, which was independent of lesion size. Total procedure time ranged from 16.3 to 45.0 min (mean [+/- SD] procedure time, 26.9 +/- 6.5 min). The mean navigation error was 9 +/- 6 mm (range, 1 to 31 mm). There were two incidences of pneumothorax for which no intervention was required. When analyzed by lobar distribution, there was a trend toward a higher ENB yield in diagnosing lesions in the right middle lobe (88%). CONCLUSIONS ENB can be used as a stand-alone bronchoscopic technique without compromising diagnostic yield or increasing the risk of pneumothorax. This may result in sizable timesaving and avoids radiation exposure.

[1]  M. Ohta,et al.  Fine-needle aspiration cytologic technique for lung cancer has a high potential of malignant cell spread through the tract. , 2000, Chest.

[2]  T. Gildea,et al.  Electromagnetic navigation diagnostic bronchoscopy: a prospective study. , 2006, American journal of respiratory and critical care medicine.

[3]  Y. Onodera,et al.  Endobronchial ultrasonography with guide-sheath for peripheral pulmonary lesions , 2004, European Respiratory Journal.

[4]  Ravi Murthy,et al.  Small (, 2005, Radiology.

[5]  Yun-Chung Cheung,et al.  Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. , 2004, Chest.

[6]  P. Pairolero,et al.  Video-assisted thoracic surgical procedures: the Mayo experience. , 1996, Mayo Clinic proceedings.

[7]  J. Austin,et al.  Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. , 2005, Radiology.

[8]  Ella A Kazerooni,et al.  The solitary pulmonary nodule. , 2003, Chest.

[9]  F. Herth,et al.  Electromagnetic Navigation during Flexible Bronchoscopy , 2003, Respiration.

[10]  Douglas C McCrory,et al.  Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. , 2003, Chest.

[11]  A. Ernst,et al.  Bronchoscopic Biopsy of Peripheral Lung Lesions Under Electromagnetic Guidance , 2005 .

[12]  Daniel Y Sze,et al.  CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. , 2003, Radiology.

[13]  Paul M. Suratt,et al.  Deaths and complications associated with fiberoptic bronchoscopy. , 1976, Chest.

[14]  W. Baaklini,et al.  Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. , 2000, Chest.

[15]  Haya R Rubin,et al.  Patient satisfaction with bronchoscopy. , 2002, American journal of respiratory and critical care medicine.

[16]  A. Ernst,et al.  Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. , 2006, Chest.

[17]  Masaki Murayama,et al.  Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. , 2004, Chest.

[18]  H. Feußner,et al.  Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy. , 2005, Chest.

[19]  F. Herth,et al.  Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules: a prospective trial. , 2006, Chest.

[20]  F. Herth,et al.  Endobronchial ultrasound-guided transbronchial lung biopsy in solitary pulmonary nodules and peripheral lesions , 2002, European Respiratory Journal.

[21]  S J Mentzer,et al.  The safety and versatility of video-thoracoscopy: a prospective analysis of 895 consecutive cases. , 1996, Journal of the American College of Surgeons.

[22]  O. Miettinen,et al.  Survival of Patients with Stage I Lung Cancer Detected on CT Screening , 2008 .

[23]  Paolo Battistoni,et al.  Endobronchial ultrasound-driven biopsy in the diagnosis of peripheral lung lesions. , 2005, Chest.