Radiation protection in pediatric radiology.

BACKGROUND The German Federal Law on Radiation Control contains no special provisions for X-ray studies in children and adolescents, even though exposure to ionizing radiation must be kept especially low in young persons, because their tissues are highly radiosensitive. Children, who have many years left to live, are more likely than adults to develop radiation-induced cancer; also, as future parents, they are at risk for passing on radiation-induced genetic defects to the next generation. Whenever possible, radiological studies on children and adolescents should be of a type that does not involve ionizing radiation, such as ultrasonography or magnetic resonance imaging. Pediatric conventional X-rays and computerized tomography (CT) require special examining techniques and protocols that are adapted to the patient's age and to the indication for the study. METHODS We selectively review the literature on pediatric dose reduction and discuss our own investigations on the subject as well. RESULTS The essential technical prerequisites for lowering the dose of ionizing radiation in conventional X-ray studies include the proper setting of tube voltage, the use of tube filters, suitable patient positioning and fixation, variable use of a scattered-radiation grid, and a modern storage-plate system. In CT studies, the use of age- and indication-adapted protocols can lower radiation exposure by as much as 95%. CONCLUSION There are now many ways to lower the exposure of children and adolescents to ionizing radiation without sacrificing diagnostic reliability. The main factors in lowering exposure are proper attention to clinical indications, the use of special X-ray protocols, the use of alternative imaging studies without ionizing radiation wherever possible, and the expertise of the examiner.

[1]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[2]  R. Günther,et al.  Mehrschicht-Spiral-CT (MSCT) in der Kinderradiologie: Dosisreduktion bei der Untersuchung von Thorax und Abdomen , 2004 .

[3]  J. Friedberg,et al.  Second malignancy after Hodgkin disease treated with radiation therapy with or without chemotherapy: long-term risks and risk factors. , 2002, Blood.

[4]  D. Fairclough,et al.  Second malignancies after Ewing's sarcoma: radiation dose-dependency of secondary sarcomas. , 1996, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[5]  R. Arthur,et al.  The Quality Criteria for Diagnostic Radiographic Images in Paediatrics , 1998 .

[6]  David J Brenner,et al.  Estimated radiation risks potentially associated with full-body CT screening. , 2004, Radiology.

[7]  C. Schneider,et al.  Die quantitative Verteilung des erythropoetischen Knochenmarks beim Menschen gemessen mit Radioeisen , 1966, Klinische Wochenschrift.

[8]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[9]  B. Stöver,et al.  CT-Untersuchungen bei Kindern , 2008, Der Radiologe.

[10]  David J. Brenner,et al.  Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative , 2002, Pediatric Radiology.

[11]  R. Loose,et al.  [Medical radiation exposure and justification at a large teaching hospital: comparison of radiation-related and disease-related risks]. , 2010, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[12]  Rainer Raupach,et al.  Dose performance of a 64-channel dual-source CT scanner. , 2007, Radiology.

[13]  E. Hall,et al.  Lessons we have learned from our children: cancer risks from diagnostic radiology , 2002, Pediatric Radiology.

[14]  R. Günther,et al.  Prospective evaluation of image quality with use of a patient image gallery for dose reduction in pediatric 16-MDCT. , 2008, AJR. American journal of roentgenology.

[15]  G. Brix,et al.  Strahlenexposition von Patienten durch diagnostische und interventionelle Röntgenanwendungen , 2005, Der Radiologe.