Amperometric biosensor for hydrogen peroxide based on ferrocene-bovine serum albumin and multiwall carbon nanotube modified ormosil composite.

A novel amperometric biosensor for hydrogen peroxide (H(2)O(2)) was developed by entrapping horseradish peroxidase (HRP) in a new ormosil composite doped with ferrocene monocarboxylic acid-bovine serum albumin conjugate and multiwall carbon nanotubes (MWNTs). The ormosil was prepared using 3-(aminopropyl)triethoxysilane and 2-(3,4 epoxycyclohexyl)-ethyltrimethoxy silane as monomers. The encapsulated conjugate showed excellent electrochemistry and acted as an electron transfer mediator. The presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H(2)O(2). The proposed H(2)O(2) biosensor exhibited a linear range of 0.02-4.0 mM with a detection limit of 5.0 microM (S/N = 3) and a K(M)(app) value of 2.0 mM. It could be used for flow injection analysis of hydrogen peroxide with a liner range from 0.02 to 4.5 mM, sensitivity of 0.042 microA/mM and analytical time of 20 s per sample. This biosensor possessed good analytical performance and storage stability.

[1]  C. Padeste,et al.  Ferrocene-avidin conjugates for bioelectrochemical applications. , 2000, Biosensors & bioelectronics.

[2]  P. Pandey,et al.  A Novel Ferrocene-Encapsulated Palladium-Linked Ormosil-Based Electrocatalytic Biosensor. The Role of the Reactive Functional Group , 2001 .

[3]  Beatriz Alonso,et al.  Preparation of biosensors based in a siloxane homopolymer with interacting ferrocenes for the amperometric detection of peroxides , 2004 .

[4]  Liping Jiang,et al.  A Chitosan-Multiwall Carbon Nanotube Modified Electrode for Simultaneous Detection of Dopamine and Ascorbic Acid , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[5]  Rodney Andrews,et al.  Carbon Nanotube Sol−Gel Composite Materials , 2001 .

[6]  Huangxian Ju,et al.  Immobilization of Biomolecules in Sol–Gels: Biological and Analytical Applications , 2006 .

[7]  Iqbal Gill,et al.  Bio-doped Nanocomposite Polymers: Sol-Gel Bioencapsulates , 2001 .

[8]  G. S. Wilson,et al.  Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer , 1980 .

[9]  P C Pandey,et al.  Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode. , 2003, Biosensors & bioelectronics.

[10]  S. Dong,et al.  Amperometric enzyme electrode for the determination of hydrogen peroxide based on sol–gel/hydrogel composite film , 2000 .

[11]  M. Garciaarmada Preparation of biosensors based in a siloxane homopolymer with interacting ferrocenes for the amperometric detection of peroxides , 2004 .

[12]  H. Ju,et al.  Preparation of porous titania sol-gel matrix for immobilization of horseradish peroxidase by a vapor deposition method. , 2002, Analytical chemistry.

[13]  Masayoshi Watanabe,et al.  Tethered mediator biosensor. Mediated electron transfer between redox enzyme and electrode via ferrocene anchored to electrode surface with long poly(oxyethylene) chain , 1999 .

[14]  Swee Ngin Tan,et al.  Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide , 1996 .

[15]  Chang Bs,et al.  Enzyme thermostabilization by bovine serum albumin and other proteins: evidence for hydrophobic interactions , 1995, Biotechnology and applied biochemistry.

[16]  H. Ju,et al.  Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine-modified gold electrode. , 2000, Analytical biochemistry.

[17]  S. Dong,et al.  Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material. , 1998, Analytical chemistry.

[18]  H. A. Harbury Oxidation-reduction potentials of horseradish peroxidase. , 1953, The Journal of biological chemistry.

[19]  A. Mulchandani,et al.  Ferrocene-conjugated m-phenylenediamine conducting polymer-incorporated peroxidase biosensors. , 1999, Analytical biochemistry.

[20]  M. Delvaux,et al.  Electrocatalytic H2O2 amperometric detection using gold nanotube electrode ensembles , 2004 .

[21]  I. Cuadrado,et al.  Ferrocenyl silicon-based dendrimers as mediators in amperometric biosensors , 1997 .

[22]  Lei Su,et al.  Sol-gel-derived ceramic-carbon nanotube nanocomposite electrodes: tunable electrode dimension and potential electrochemical applications. , 2004, Analytical chemistry.

[23]  B. González,et al.  Electrodes modified with a siloxane copolymer containing interacting ferrocenes for determination of hydrogen peroxide and glucose , 2003 .

[24]  P. Pandey,et al.  An ormosil-based peroxide biosensor — a comparative study on direct electron transport from horseradish peroxidase , 2001 .

[25]  Songqin Liu,et al.  Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode. , 2002, Analytical biochemistry.

[26]  K. Yokoyama,et al.  Electrochemical characterization of an enzyme electrode based on a ferrocene-containing redox polymer , 1999 .