Automated Circuit Breaker Monitoring

Circuit breakers are used in a power system to break or make current flow through power system apparatus. The action of circuit breakers changes switching topology of a power system. Reliable operation of circuit breakers is critical to the ability to reconfigure a power system and can be assured by regular inspection and maintenance. An automated circuit breaker monitoring system is proposed to monitor circuit breaker's control circuit. System is designed to enable deployment of system-wide applications that utilize the data recorded by the system. An application of system wide data analysis is demonstrated. It makes possible to track the circuit breaker switching sequences and make conclusions about their performance and final outcome. Lab and field evaluation of the designed system is performed and results are presented.

[1]  L. Essen Frequency and Time Standards , 1962, Proceedings of the IRE.

[2]  M. A. Hughes Distance relay performance as affected by capacitor voltage transformers , 1974 .

[3]  Linders Transient response of current transformers , 1977, IEEE Transactions on Power Apparatus and Systems.

[4]  H. Fleck [Analysis of the sequence of operations in a medical examination center with the aid of network technique (author's transl)]. , 1977, Methods of information in medicine.

[5]  Terry A. Welch,et al.  A Technique for High-Performance Data Compression , 1984, Computer.

[6]  G. Beauchamp Background Information , 1987, Journal of learning disabilities.

[7]  M. I. Samesima,et al.  Frequency response analysis and modeling of measurement transformers under distorted current and voltage supply , 1991 .

[8]  Ieee Standards Board IEEE standard common format for transient data exchange (COMTRADE) for power systems , 1991 .

[9]  C. Thomas,et al.  GPS time transfer , 1991 .

[10]  Mladen Kezunovic,et al.  Synchronized sampling and phasor measurements for relaying and control , 1994 .

[11]  D.A. Gabel Application software , 1994, IEEE Spectrum.

[12]  H. Wayne Beaty,et al.  Electrical Power Systems Quality , 1995 .

[13]  Ramjee Prasad,et al.  An overview of multi-carrier CDMA , 1996, Proceedings of ISSSTA'95 International Symposium on Spread Spectrum Techniques and Applications.

[14]  A.G. Phadke,et al.  Proposed Statistical Performance Measures for Microprocessor-Based Transmission-Line Protective Relays, Part 1: Explanation of the Statistics , 1997, IEEE Power Engineering Review.

[15]  W. J. Klepczynski,et al.  GPS: primary tool for time transfer , 1999, Proc. IEEE.

[16]  C. Christopoulos,et al.  Electrical power system protection , 1999 .

[17]  E. Kenneth,et al.  PRECISE TIMING IN ELECTRIC POWER SYSTEMS , 2000 .

[18]  Mladen Kezunovic,et al.  Mathematical models for current, voltage, and coupling capacitor voltage transformers , 2000 .

[19]  Mladen Kezunovic,et al.  Design optimization and performance evaluation of the relaying algorithms, relays and protective systems using advanced testing tools , 2000 .

[20]  Mark Christensen,et al.  Software Requirements Specification , 2001 .

[21]  M. Kezunovic,et al.  Design and Implementation of Scenarios for Evaluating and Testing Distance Relays , 2001 .

[22]  H. O. Pascual,et al.  Behaviour of Fourier, cosine and sine filtering algorithms for distance protection, under severe saturation of the current magnetic transformer , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[23]  J. C. Townsend,et al.  Software Requirements Specification , 2001 .

[24]  Lj.A. Kojovic Impact of current transformer saturation on overcurrent protection operation , 2002, IEEE Power Engineering Society Summer Meeting,.

[25]  H. M. Shuh,et al.  Transmission Protective Relay System Performance Measuring Methodology IEEE / PSRC Working Group I 3 9 / 16 / 1999 , 2002 .

[26]  R. Thomas,et al.  Condition monitoring and maintenance strategies for high-voltage circuit-breakers , 2003 .

[27]  G. Peceli,et al.  Synchronization of sampling in distributed signal processing systems , 2003, IEEE International Symposium on Intelligent Signal Processing, 2003.

[28]  E. P.,et al.  Wireless Communications in Substations , 2003 .

[29]  Gary Riley,et al.  Expert Systems: Principles and Programming , 2004 .

[30]  Marion Kee,et al.  Analysis , 2004, Machine Translation.

[31]  Mladen Kezunovic,et al.  Automated monitoring functions for improved power system operation and control , 2005 .

[32]  M. Kezunovic,et al.  Automated monitoring and analysis of circuit breaker operation , 2005, IEEE Transactions on Power Delivery.

[33]  M. Kezunovic,et al.  Robust topology determination based on additional substation data from IEDs , 2005, 2005 IEEE Russia Power Tech.

[34]  M. Runde,et al.  Continuous monitoring of circuit breakers using vibration analysis , 2005, IEEE Transactions on Power Delivery.

[35]  Magne Runde,et al.  Continuous monitoring of circuit breakers using vibration analysis , 2005 .

[36]  Daniel Karlsson,et al.  Wide-Area Protection and Power System Utilization , 2005, Proceedings of the IEEE.

[37]  Ali Abur,et al.  Merging the Temporal and Spatial Aspects of Data and Information for Improved Power System Monitoring Applications , 2005, Proceedings of the IEEE.

[38]  Mladen Kezunovic Monitoring of Power System Topology in Real-Time , 2006, Proceedings of the 39th Annual Hawaii International Conference on System Sciences (HICSS'06).

[39]  J. Lewis Blackburn,et al.  Protective Relaying: Principles And Applications , 2006 .

[40]  Martti Juhola,et al.  Data Classification , 2019, Wiley Encyclopedia of Computer Science and Engineering.

[41]  L Swadner Graphical User Interface , 2009, Encyclopedia of Biometrics.