Evaluation of accuracy, reliability, and repeatability of five dental pulp tests.

INTRODUCTION The aim of this study was to compare the clinical accuracy, reliability, and repeatability of laser Doppler flowmetry (LDF), an electric pulp test (EPT), and various thermal pulp sensibility tests. METHODS Pulp tests were done on 121 teeth in 20 subjects by using LDF, EPT, and thermal pulp testing (CO(2), Endo Frost [EF], Ice) during 2 or 3 test sessions with at least 1-week intervals. The order of testing was reversed on the second visit. A laser Doppler flowmeter was used to measure mean pulp blood flow (Flux) calibrated against a brownian motion medium and zeroed against a static reflector. The laser source was 780 nm, with 0.5-mm fiber separation in the probe, 3.1 kHz as the primary bandwidth for filter set to 0.1-second time output constant. Customized polyvinylsiloxane splints were fabricated for each participant, and a minimum of 90-second recording time was used for each tooth. Raw data were analyzed by using repeated measure analysis of variance, pairwise comparisons, and interclass correlations (ICC). RESULTS The accuracy of EPT, CO(2), and LDF tests was 97.7%, 97.0%, and 96.3%, respectively, without significant differences (P > .3). Accuracy of EF and Ice was 90.7% and 84.8%, respectively. EPT (P = .015) and CO(2) (P = .022) were significantly more accurate than EF. LDF was more accurate than EF, but this was not statistically significant (P = .063). Ice was significantly less accurate than EPT (P = .004), CO(2) (P = .005), LDF (P = .006), and EF (P = .019). With the exception of Ice (effect of visit: F(2,38) = 5.67, mean squared error = 0.01, P = .007, η(2)(p) = 0.23), all tests were reliable. Ice (ICC = 0.677) and LDF (ICC = 0.654) were the most repeatable of the tests, whereas EPT (ICC = 0.434) and CO(2) (ICC = 0.432) were less repeatable. CONCLUSIONS CO(2), EPT, and LDF were reliable and the most accurate tests, but CO(2) and EPT were less repeatable yet less time-consuming than LDF. EF was reliable but not as accurate as EPT and CO(2) and less repeatable than Ice and LDF. Ice was the most repeatable but the least accurate and least reliable test.

[1]  D. Stirrups,et al.  The effect of wavelength, bandwidth, and probe design and position on assessing the vitality of anterior teeth with laser Doppler flowmetry. , 2001, International journal of paediatric dentistry.

[2]  L Lorton,et al.  Adult pulpal diagnosis. I. Evaluation of the positive and negative responses to cold and electrical pulp tests. , 1994, Journal of endodontics.

[3]  B Matthews,et al.  The sources of laser Doppler blood-flow signals recorded from human teeth. , 2003, Archives of oral biology.

[4]  T. Dumsha,et al.  The reliability of electric pulp test after concussion injury. , 1996, Endodontics & dental traumatology.

[5]  R. Emshoff,et al.  Diagnostic characteristics of pulpal blood flow levels associated with adverse outcomes of luxated permanent maxillary incisors. , 2004, Dental traumatology : official publication of International Association for Dental Traumatology.

[6]  K. Er,et al.  The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth. , 2004, Archives of oral biology.

[7]  J. Strother,et al.  Cold testing through full-coverage restorations. , 2004, Journal of endodontics.

[8]  S Sorin,et al.  Assessment of reliability of electrical and thermal pulp testing agents. , 1986, Journal of endodontics.

[9]  J W Myers,et al.  Demonstration of a possible source of error with an electric pulp tester. , 1998, Journal of endodontics.

[10]  R. Emshoff,et al.  Evaluation of pulpal blood flow after tooth splinting of luxated permanent maxillary incisors. , 2004, Dental traumatology : official publication of International Association for Dental Traumatology.

[11]  R. Walton,et al.  Comparison of carbon dioxide versus refrigerant spray to determine pulpal responsiveness. , 2002, Journal of endodontics.

[12]  Z. Fuss,et al.  Effects of thermal vitality tests on human dental pulp. , 1988, Journal of endodontics.

[13]  E H Ehrmann,et al.  Pulp testers and pulp testing with particular reference to the use of dry ice. , 1977, Australian dental journal.

[14]  R. Emshoff,et al.  Use of laser Doppler flowmetry to predict vitality of luxated or avulsed permanent teeth. , 2004, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[15]  S N Bhaskar,et al.  Dental vitality tests and pulp status. , 1973, Journal of the American Dental Association.

[16]  R. Hirsch,et al.  Tooth discoloration and resolution following a luxation injury: significance of blood pigment in dentin to laser Doppler flowmetry readings. , 1993, Quintessence international.

[17]  D. D. Peters,et al.  Evaluation of the effects of carbon dioxide used as a pulpal test. Part 2. In vivo effect on canine enamel and pulpal tissues. , 1983, Journal of endodontics.

[18]  I. B. Bender,et al.  The optimum placement-site of the electrode in electric pulp testing of the 12 anterior teeth. , 1989, Journal of the American Dental Association.

[19]  R. Emshoff,et al.  Assessing revascularization of avulsed permanent maxillary incisors by laser Doppler flowmetry. , 2003, Journal of the American Dental Association.

[20]  T R Pitt Ford,et al.  The assessment of pulpal vitality. , 1990, International endodontic journal.

[21]  Mumford Jm,et al.  Thermal and electrical stimulation of teeth in the diagnosis of pulpal and periapical disease. , 1967 .

[22]  A Rawlinson,et al.  A comparison between two electric vitality testers and ethyl chloride with special reference to a newly available device. , 1988, International endodontic journal.

[23]  D. Stirrups,et al.  A comparison of laser Doppler flowmetry with other methods of assessing the vitality of traumatised anterior teeth. , 1999, Endodontics & dental traumatology.

[24]  E A Pantera,et al.  Reliability of electric pulp testing after pulpal testing with dichlorodifluoromethane. , 1993, Journal of endodontics.

[25]  R. Emshoff,et al.  Pulpal blood-flow characteristics of maxillary tooth morphotypes as assessed with laser Doppler flowmetry. , 1999, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[26]  J. C. Donnelly,et al.  Evaluation of the effects of carbon dioxide used as a pulpal test. 3. In vivo effect on human enamel. , 1986, Journal of endodontics.

[27]  I. B. Bender Reversible and irreversible painful pulpitides: diagnosis and treatment. , 2000, Australian endodontic journal : the journal of the Australian Society of Endodontology Inc.

[28]  C E Riva,et al.  Efficacy of laser Doppler flowmetry in determining pulp vitality of human teeth. , 1994, Endodontics & dental traumatology.

[29]  R. Emshoff,et al.  Laser Doppler flow measurements of pulpal blood flow and severity of dental injury. , 2004, International endodontic journal.

[30]  J. Andreasen,et al.  Influence of maturation status and tooth type of permanent teeth upon electrometric and thermal pulp testing. , 1976, Scandinavian journal of dental research.

[31]  K Petersson,et al.  Evaluation of the ability of thermal and electrical tests to register pulp vitality. , 1999, Endodontics & dental traumatology.

[32]  D. D. Peters,et al.  In vitro effects of ice, skin refrigerant, and CO2 snow on intrapulpal temperature. , 1981, Journal of endodontics.