Architectural properties of the first dorsal interosseous muscle

Muscle architecture is considered to reflect the function of muscle in vivo, and is important for example to clinicians in designing tendon‐transfer and tendon‐lengthening surgeries. The purpose of this study was to quantify the architectural properties of the FDI muscle. It is hypothesized that there will be consistency, that is low variability, in the architectural parameters used to describe the first dorsal interosseous muscle because of its clear functional role in index finger motion. The important architectural parameters identified were those required to characterize a muscle adequately by modeling. Specifically the mass, cross‐sectional area, and length of the tendon and muscle were measured in cadavers along with the muscle fiber optimum length and pennation angle, and the moment arm of the first dorsal interosseous at the metacarpophalangeal joint. These parameters provide a characterization of the architecture of the first dorsal interosseous, and were used to indicate the inherent variability between samples. The results demonstrated a large amount of variability for all architectural parameters measured; leading to a rejection of the hypothesis. Ratios designed to describe the functioning of the muscles in vivo, for example the ratio of tendon to fiber optimum lengths, also demonstrated a large variability. The results suggest that function cannot be deduced from form for the first dorsal interosseous, and that subject‐specific architectural parameters may be necessary for the formulation of accurate musculoskeletal models or making clinical decisions.

[1]  M. J. N. McDonagh,et al.  Measurement of muscle and tendon stiffness in man , 2004, European Journal of Applied Physiology and Occupational Physiology.

[2]  J. H. Challis Muscle‐Tendon Architecture and Athletic Performance , 2008 .

[3]  D. Eyler,et al.  The anatomy and function of the intrinsic musculature of the fingers. , 1954, The Journal of bone and joint surgery. American volume.

[4]  R. Close Dynamic properties of fast and slow skeletal muscles of the rat during development , 1964, The Journal of physiology.

[5]  G. N. Crawford,et al.  The thickness and collagen content of tendon relative to the strength and cross-sectional area of muscle , 1965, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[6]  R C Payne,et al.  Functional anatomy and muscle moment arms of the thoracic limb of an elite sprinting athlete: the racing greyhound (Canis familiaris) , 2008, Journal of anatomy.

[7]  J. Fridén,et al.  Functional and clinical significance of skeletal muscle architecture , 2000, Muscle & nerve.

[8]  J. Fridén,et al.  Human wrist motors: biomechanical design and application to tendon transfers. , 1996, Journal of biomechanics.

[9]  K. An,et al.  Tendon excursion and moment arm of index finger muscles. , 1983, Journal of biomechanics.

[10]  P. Brand,et al.  Relative tension and potential excursion of muscles in the forearm and hand. , 1981, The Journal of hand surgery.

[11]  R. Alexander,et al.  Storage of elastic strain energy in muscle and other tissues , 1977, Nature.

[12]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[13]  R. F. Ker Dynamic tensile properties of the plantaris tendon of sheep (Ovis aries). , 1981, The Journal of experimental biology.

[14]  V. Edgerton,et al.  Predictability of skeletal muscle tension from architectural determinations in guinea pig hindlimbs. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.

[15]  R L Lieber,et al.  Skeletal muscle architecture: implications for muscle function and surgical tendon transfer. , 1993, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[16]  S. Piazza,et al.  An algorithm for automated analysis of ultrasound images to measure tendon excursion in vivo. , 2008, Journal of applied biomechanics.

[17]  R. F. Ker,et al.  Ratios of cross-sectional areas of muscles and their tendons in a healthy human forearm. , 1991, Journal of anatomy.

[18]  R. M. Alexander,et al.  Elastic mechanisms in animal movement , 1988 .

[19]  R. Enoka,et al.  Practice reduces motor unit discharge variability in a hand muscle and improves manual dexterity in old adults. , 2005, Journal of applied physiology.

[20]  R C Payne,et al.  Functional anatomy and muscle moment arms of the pelvic limb of an elite sprinting athlete: the racing greyhound (Canis familiaris) , 2008, Journal of anatomy.

[21]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[22]  R. Bottinelli,et al.  Whole-muscle and single-fibre contractile properties and myosin heavy chain isoforms in humans , 1996, Pflügers Archiv.

[23]  C. Maganaris,et al.  Muscle fibre length-to-moment arm ratios in the human lower limb determined in vivo. , 2006, Journal of biomechanics.

[24]  E. Otten Concepts and Models of Functional Architecture in Skeletal Muscle , 1988, Exercise and sport sciences reviews.

[25]  J. Faulkner,et al.  Contractile properties of skeletal muscles from young, adult and aged mice. , 1988, The Journal of physiology.

[26]  M. Johnson,et al.  Data on the distribution of fibre types in thirty-six human muscles. An autopsy study. , 1973, Journal of the neurological sciences.

[27]  R. F. Ker,et al.  The Architecture of Leg Muscles , 1990 .

[28]  C. Gans,et al.  The functional significance of muscle architecture--a theoretical analysis. , 1965, Ergebnisse der Anatomie und Entwicklungsgeschichte.

[29]  R. Brand,et al.  Muscle fiber architecture in the human lower limb. , 1990, Journal of biomechanics.

[30]  R. Hughes,et al.  Musculoskeletal parameters of muscles crossing the shoulder and elbow and the effect of sarcomere length sample size on estimation of optimal muscle length. , 2004, Clinical biomechanics.

[31]  S. Walker,et al.  I segment lengths and thin filament periods in skeletal muscle fibers of the rhesus monkey and the human , 1974, The Anatomical record.

[32]  R. Lieber,et al.  Architectural design of the human intrinsic hand muscles. , 1992, The Journal of hand surgery.

[33]  Ian David Loram,et al.  Use of ultrasound to make noninvasive in vivo measurement of continuous changes in human muscle contractile length. , 2006, Journal of applied physiology.

[34]  P. Rack,et al.  Elastic properties of the cat soleus tendon and their functional importance. , 1984, The Journal of physiology.

[35]  T. Kardel Niels Stensen's geometrical theory of muscle contraction (1667): a reappraisal. , 1990, Journal of biomechanics.

[36]  Adaptation of mechanical properties of muscle to high force training in man. , 1985, The Journal of physiology.

[37]  A. Masquelet,et al.  Morphology and functional anatomy of the first dorsal interosseous muscle of the hand , 2006, Surgical and Radiologic Anatomy.

[38]  D'arcy W. Thompson,et al.  On Growth and Form , 1917, Nature.

[39]  R. Stein,et al.  Changes in firing rate of human motor units during linearly changing voluntary contractions , 1973, The Journal of physiology.

[40]  The isometric length-tension diagram of isolated skeletal muscle fibers of the frog , 2005, Protoplasma.

[41]  John H Challis,et al.  The validity of ultrasound estimation of muscle volumes. , 2007, Journal of applied biomechanics.