Measurement of Intraoperative Brain Surface Deformation Under a Craniotomy

OBJECTIVE Several causes of spatial inaccuracies in image-guided surgery have been carefully studied and documented for several systems. These include error in identifying the external features used for registration, geometrical distortion in the preoperative images, and error in tracking the surgical instruments. Another potentially important source of error is brain deformation between the time of imaging and the time of surgery or during surgery. In this study, we measured the deformation of the dura and brain surfaces between the time of imaging and the start of surgical resection for 21 patients. METHODS All patients underwent intraoperative functional mapping, allowing us to measure brain surface motion at two times that were separated by nearly an hour after opening the dura but before performing resection. The positions of the dura and brain surfaces were recorded and transformed to the coordinate space of a preoperative magnetic resonance image, using the Acustar surgical navigation system (manufactured by Johnson & Johnson Professional, Inc., Randolph, MA) (the Acustar trademark and associated intellectual property rights are now owned by Picker International, Highland Heights, OH). This system performs image registration with bone-implanted markers and tracks a surgical probe by optical triangulation. RESULTS The mean displacements of the dura and the first and second brain surfaces were 1.2, 4.4, and 5.6 mm, respectively, with corresponding mean volume reductions under the craniotomy of 6, 22, and 29 cc. The maximum displacement was greater than 10 mm in approximately one-third of the patients for the first brain surface measurement and one-half of the patients for the second. In all cases, the direction of brain shift corresponded to a "sinking" of the brain intraoperatively, compared with its preoperative position. Analysis of the measurement error revealed that its magnitude was approximately 1 to 2 mm. We observed two different patterns of the brain surface deformation field, depending on the inclination of the craniotomy with respect to gravity. Separate measurements of brain deformation within the closed cranium caused by changes in patient head orientation with respect to gravity suggested that less than 1 mm of the brain shift recorded intraoperatively could have resulted from the change in patient orientation between the time of imaging and the time of surgery. CONCLUSION These results suggest that intraoperative brain deformation is an important source of error that needs to be considered when using surgical navigation systems.

[1]  Thomas W. Sederberg,et al.  Conversion of complex contour line definitions into polygonal element mosaics , 1978, SIGGRAPH.

[2]  P. Kelly,et al.  Computer-assisted stereotaxic laser resection of intra-axial brain neoplasms. , 1986, Journal of neurosurgery.

[3]  J. Strohbehn,et al.  A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. , 1986, Journal of neurosurgery.

[4]  F. Nath,et al.  The effect of mannitol on cerebral white matter water content. , 1986, Journal of neurosurgery.

[5]  J. Best,et al.  BRAIN WATER MEASURED BY MAGNETIC RESONANCE IMAGING Correlation with Direct Estimation and Changes After Mannitol and Dexamethasone , 1987, The Lancet.

[6]  Y. Kosugi,et al.  An articulated neurosurgical navigation system using MRI and CT images , 1988, IEEE Transactions on Biomedical Engineering.

[7]  E.M. Friets,et al.  A frameless stereotaxic operating microscope for neurosurgery , 1989, IEEE Transactions on Biomedical Engineering.

[8]  C S Henriquez,et al.  Finite element analysis of bioelectric phenomena. , 1990, Critical reviews in biomedical engineering.

[9]  J. Mugler,et al.  Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE) , 1990, Magnetic resonance in medicine.

[10]  Werner Krybus,et al.  Computer-assisted surgery , 1990, IEEE Computer Graphics and Applications.

[11]  Á. Kuncz,et al.  The effect of skull and dura on brain volume regulation after hypo- and hyperosmolar fluid treatment. , 1990, Neurosurgery.

[12]  T. Yoshimine,et al.  A frameless, armless navigational system for computer-assisted neurosurgery. Technical note. , 1991, Journal of neurosurgery.

[13]  R. Maciunas,et al.  Interactive image-guided neurosurgery , 1992, IEEE Transactions on Biomedical Engineering.

[14]  V. Wedeen,et al.  Brain parenchyma motion: measurement with cine echo-planar MR imaging. , 1992, Radiology.

[15]  J. Koivukangas,et al.  Ultrasound-controlled neuronavigator-guided brain surgery. , 1993, Journal of neurosurgery.

[16]  C. Jack,et al.  Sensory motor cortex: correlation of presurgical mapping with functional MR imaging and invasive cortical mapping. , 1994, Radiology.

[17]  T. Allison,et al.  Functional magnetic resonance imaging of sensory and motor cortex: comparison with electrophysiological localization. , 1995, Journal of neurosurgery.

[18]  L. Smith,et al.  Clinical use of a frameless stereotactic arm: results of 325 cases. , 1995, Journal of neurosurgery.

[19]  R L Stalnaker,et al.  A constitutive relationship for large deformation finite element modeling of brain tissue. , 1995, Journal of biomechanical engineering.

[20]  Robert A. Hummel,et al.  Exploiting Triangulated Surface Extraction Using Tetrahedral Decomposition , 1995, IEEE Trans. Vis. Comput. Graph..

[21]  Benoit M. Dawant,et al.  Registration of 3-D images using weighted geometrical features , 1996, IEEE Trans. Medical Imaging.

[22]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[23]  Benoit M. Dawant,et al.  Comparison and evaluation of retrospective intermodality image registration techniques , 1996, Medical Imaging.

[24]  Richard J. Evans,et al.  Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging , 1996, Medical Image Anal..

[25]  Derek L. G. Hill,et al.  Estimation of intraoperative brain surface movement , 1997, CVRMed.

[26]  Jason Trobaugh,et al.  The correction of stereotactic inaccuracy caused by brain shift using an intraoperative ultrasound device , 1997, CVRMed.

[27]  A. Khotanzad,et al.  A physics-based coordinate transformation for 3-D image matching , 1997, IEEE Transactions on Medical Imaging.

[28]  Gerald Q. Maguire,et al.  Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.

[29]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[30]  D L Hill,et al.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. , 1997, Medical physics.

[31]  David J. Hawkes,et al.  A three-component deformation model for image-guided surgery , 1998, Medical Image Anal..

[32]  J. Buurman,et al.  Early Clinical Experience with the EasyGuide Neuronavigation System and Measurement of Intraoperative Brain Distortion , 1998 .