Comparison of the performance of pulsed and continuous UVC-LED irradiation in the inactivation of bacteria.

Ultraviolet light-emitting diode (UV-LED) is a newly emerging UV light source with a potential to replace the conventional chemical methods, mercury UV lamps and xenon lamps in water disinfection. UV-LEDs are characterized by the diversity in wavelengths and can be turned on and off with a high and adjustable frequency, making them an attractive candidate for pulsed light (PL) disinfection apart from the conventional continuous wave (CW) operation. Previous studies on comparison between the PL and CW UV-LED irradiations for the inactivation of bacterium in water disinfection are limited and results conflict. In this work, PL and CW UV-LED in the C-spectral band (UVC-LED) irradiations were compared at equivalent fluence in the inactivation and subsequent photoreactivation of E. coli bacteria. In addition, effect of different driving currents and ambient temperatures on solder temperature of the PL and CW UVC-LED irradiation was also examined. Under the equivalent fluences, the PL and CW UVC-LED irradiations brought comparable inactivation efficiency and similar photoreactivation of the E. coli. Moreover, the PL UVC-LED exhibited a much lower solder temperature than the CW UVC-LED irradiation. On the other hand, CW UVC-LED irradiation, higher ambient temperature and higher driving current increased the solder temperature that resulted to a negative impact on the wavelength, full width at half maximum, optical power and irradiance, which are key factors in the UVC-LED disinfection efficiency. In all, this work reports the comparison between PL and CW in UVC-LED irradiation for inactivating E. coli bacteria and firstly revealed the photoreactivation of the E. coli after the PL UVC-LEDs irradiation.

[1]  N Orange,et al.  Pulsed-light system as a novel food decontamination technology: a review. , 2007, Canadian journal of microbiology.

[2]  A. Kelner Effect of Visible Light on the Recovery of Streptomyces Griseus Conidia from Ultra-violet Irradiation Injury. , 1949, Proceedings of the National Academy of Sciences of the United States of America.

[3]  K. Linden,et al.  Comparative disinfection efficiency of pulsed and continuous-wave UV irradiation technologies. , 2008, Water research.

[4]  J. Colford,et al.  Waterborne diseases. , 2001, Emerging infectious diseases.

[5]  M. Shur,et al.  Development of Deep UV LEDs and Current Problems in Material and Device Technology , 2017 .

[6]  T. Ott,et al.  Pulsed white light food processing , 1997 .

[7]  Regina Sommer,et al.  Spectral sensitivity of Bacillus subtilis spores and MS2 coliphage for validation testing of ultraviolet reactors for water disinfection. , 2005, Environmental science & technology.

[8]  Karl G. Linden,et al.  Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments , 2003 .

[9]  A. Cabaj,et al.  Time dose reciprocity in UV disinfection of water , 1998 .

[10]  Frank Devlieghere,et al.  Pulsed light for food decontamination: a review , 2007 .

[11]  J. Bolton,et al.  Comparison of the action spectra and relative DNA absorbance spectra of microorganisms: information important for the determination of germicidal fluence (UV dose) in an ultraviolet disinfection of water. , 2009, Water research.

[12]  T. Ott,et al.  Pulsed-light treatment of food and packaging , 1995 .

[13]  N. Ashbolt,et al.  Point-of-use water disinfection using ultraviolet and visible light-emitting diodes. , 2016, The Science of the total environment.

[14]  M Jekel,et al.  Application of GaN-based ultraviolet-C light emitting diodes--UV LEDs--for water disinfection. , 2011, Water research.

[15]  Variation of the external quantum efficiency with temperature and current density in red, blue, and deep ultraviolet light-emitting diodes , 2016 .

[16]  N. Gao,et al.  Enhanced inactivation of E. coli by pulsed UV-LED irradiation during water disinfection. , 2019, The Science of the total environment.

[17]  R. Beukers,et al.  Isolation and identification of the irradiation product of thymine. , 1960, Biochimica et biophysica acta.

[18]  Y. Luo,et al.  Application of micro/nano technology for thermal management of high power LED packaging – A review , 2018, Applied Thermal Engineering.

[19]  H. Hirayama,et al.  Recent Progress in AlGaN‐Based Deep‐UV LEDs , 2015 .

[20]  James Petroski Thermal challenges facing new-generation light-emitting diodes (LEDs) for lighting applications , 2002, SPIE Optics + Photonics.

[21]  Jiangyong Hu,et al.  Inactivation/reactivation of antibiotic-resistant bacteria by a novel UVA/LED/TiO2 system. , 2013, Water research.

[22]  P. Mccubbin,et al.  Pulsed UV‐C Disinfection of Escherichia coli With Light‐Emitting Diodes, Emitted at Various Repetition Rates and Duty Cycles , 2013, Photochemistry and photobiology.

[23]  Daoyi Chen,et al.  Use of coupled wavelength ultraviolet light-emitting diodes for inactivation of bacteria in subsea oil-field injection water. , 2018, The Science of the total environment.

[24]  M. Otaki,et al.  Inactivation differences of microorganisms by low pressure UV and pulsed xenon lamps. , 2003, Water science and technology : a journal of the International Association on Water Pollution Research.

[25]  J. M. Quiroga,et al.  Photoreactivation and Dark Repair in UV-Treated Microorganisms: Effect of Temperature , 2007, Applied and Environmental Microbiology.

[26]  Bruce Jefferson,et al.  Evaluating the impact of LED bulb development on the economic viability of ultraviolet technology for disinfection , 2014, Environmental technology.

[27]  J G Anderson,et al.  Pulsed ultra-violet inactivation spectrum of Escherichia coli. , 2005, Water research.

[28]  Haroon R. Mian,et al.  Prioritization of unregulated disinfection by-products in drinking water distribution systems for human health risk mitigation: A critical review. , 2018, Water research.

[29]  F. Taghipour,et al.  Microorganisms inactivation by continuous and pulsed irradiation of ultraviolet light-emitting diodes (UV-LEDs) , 2018, Chemical Engineering Journal.

[30]  J. Darby,et al.  Ultraviolet disinfection of wastewater: Effect of dose on subsequent photoreactivation , 1994 .

[31]  Mika Sillanpää,et al.  Ultraviolet light-emitting diodes in water disinfection , 2009, Environmental science and pollution research international.

[32]  F. Schmid,et al.  Biological Macromolecules: UV‐visible Spectrophotometry , 2001 .

[33]  S. Weber Light-driven enzymatic catalysis of DNA repair: a review of recent biophysical studies on photolyase. , 2005, Biochimica et biophysica acta.

[34]  F. Taghipour,et al.  Development of a method for the characterization and operation of UV-LED for water treatment. , 2017, Water research.

[35]  Mark P. Wilson,et al.  Efficacy of Pulsed 405-nm Light-Emitting Diodes for Antimicrobial Photodynamic Inactivation: Effects of Intensity, Frequency, and Duty Cycle , 2017, Photomedicine and laser surgery.

[36]  W. Harm Biological effects of ultraviolet radiation , 1980 .

[37]  K. Linden,et al.  Wavelength dependent UV inactivation and DNA damage of adenovirus as measured by cell culture infectivity and long range quantitative PCR. , 2014, Environmental science & technology.

[38]  Yinghua Lu,et al.  Effects of single and combined UV-LEDs on inactivation and subsequent reactivation of E. coli in water disinfection. , 2018, Water research.

[39]  C. Woodall Waterborne diseases – What are the primary killers? , 2009 .

[40]  N. Ashbolt,et al.  Photovoltaic powered ultraviolet and visible light-emitting diodes for sustainable point-of-use disinfection of drinking waters. , 2014, The Science of the total environment.

[41]  S. Isobe,et al.  Damage of yeast cells induced by pulsed light irradiation. , 2003, International journal of food microbiology.

[42]  X.A. Cao,et al.  Current and Temperature Dependent Characteristics of Deep-Ultraviolet Light-Emitting Diodes , 2007, IEEE Transactions on Electron Devices.

[43]  Hiroyuki Katayama,et al.  Photoreactivation of Legionella pneumophila after inactivation by low- or medium-pressure ultraviolet lamp. , 2004, Water research.

[44]  Chunlei Guo,et al.  AlGaN photonics: recent advances in materials and ultraviolet devices , 2018 .

[45]  M. Kundi,et al.  Increased inactivation of Saccharomyces cerevisiae by protraction of UV irradiation , 1996, Applied and environmental microbiology.

[46]  P. Chetia,et al.  Emergence of antibiotic resistant Shigella species: A matter of concern. , 2017, Journal of infection and public health.

[47]  K. Hirota,et al.  Enhanced germicidal effects of pulsed UV‐LED irradiation on biofilms , 2010, Journal of applied microbiology.

[48]  Dietrich Knorr,et al.  DEVELOPMENTS OF NONTHERMAL PROCESSES FOR FOOD PRESERVATION , 1992 .

[49]  F. Devlieghere,et al.  Factors affecting the inactivation of micro‐organisms by intense light pulses , 2005, Journal of applied microbiology.

[50]  X.A. Cao,et al.  Temperature-dependent electroluminescence of AlGaN-based UV LEDs , 2006, IEEE Electron Device Letters.

[51]  M. Sillanpää,et al.  Recent developments in photochemical and chemical AOPs in water treatment: a mini-review , 2010 .

[52]  J. Irudayaraj,et al.  Inactivation of Staphylococcus aureus in milk using flow-through pulsed UV-light treatment system. , 2007, Journal of food science.

[53]  T. Egli,et al.  UV‐C inactivation in Escherichia coli is affected by growth conditions preceding irradiation, in particular by the specific growth rate , 2010, Journal of applied microbiology.

[54]  Gemma Oms-Oliu,et al.  Pulsed Light Treatments for Food Preservation. A Review , 2010 .

[55]  J. Bolton,et al.  An Approach to Standardize Methods for Fluence Determination in Bench-Scale Pulsed Light Experiments , 2016, Food and Bioprocess Technology.

[56]  F. L. Gates A STUDY OF THE BACTERICIDAL ACTION OF ULTRA VIOLET LIGHT , 1929, The Journal of general physiology.

[57]  Chen-yan Hu,et al.  Factors affecting the water odor caused by chloramines during drinking water disinfection. , 2018, The Science of the total environment.

[58]  P. H. Quek,et al.  Influence of photoreactivating light intensity and incubation temperature on photoreactivation of Escherichia coli following LP and MP UV disinfection , 2008, Journal of applied microbiology.

[59]  J. Rice,et al.  Examination of Peak Power Dependence in the UV Inactivation of Bacterial Spores , 2001, Applied and Environmental Microbiology.

[60]  A. Wekhof Disinfection with flash lamps. , 2000, PDA journal of pharmaceutical science and technology.

[61]  E. Friedberg,et al.  DNA Repair and Mutagenesis , 2006 .

[62]  Michael E. Miller,et al.  Comparison of continuous versus pulsed ultraviolet light emitting diode use for the inactivation of Bacillus globigii spores. , 2014, Water science and technology : a journal of the International Association on Water Pollution Research.

[63]  Hong-Ying Hu,et al.  Comparison of UV-LED and low pressure UV for water disinfection: Photoreactivation and dark repair of Escherichia coli. , 2017, Water research.

[64]  K. Unklesbay,et al.  A comparison of pulsed and continuous ultraviolet light sources for the decontamination of surfaces , 2000 .

[65]  Wladyslaw Kowalski,et al.  Ultraviolet Germicidal Irradiation Handbook , 2009 .

[66]  B. F. Kalisvaart Re-use of wastewater: preventing the recovery of pathogens by using medium-pressure UV lamp technology. , 2004, Water science and technology : a journal of the International Association on Water Pollution Research.

[67]  J. D. Berg,et al.  Effect of antecedent growth conditions on sensitivity of Escherichia coli to chlorine dioxide , 1982, Applied and environmental microbiology.

[68]  Yoshihiko Muramoto,et al.  Development and future of ultraviolet light-emitting diodes: UV-LED will replace the UV lamp , 2014, 2015 IEEE Summer Topicals Meeting Series (SUM).