Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography.

A new method for the determination of trace levels of adsorbable organic fluorine (AOF) in water is presented. Even if the individual contributing target compounds are widely unknown, this surrogate parameter is suited to identify typical organofluorine contaminations, such as with polyfluorinated chemicals (PFCs), and represents a lower boundary of the organofluorine concentration in water bodies. It consists of the adsorption of organofluorine chemicals on a commercially available synthetic polystyrene-divinylbenzene based activated carbon (AC) followed by analysis of the loaded AC by hydropyrolysis combustion ion chromatography (CIC). Inorganic fluorine is displaced by excess nitrate during the extraction step and by washing the loaded activated carbon with an acidic sodium nitrate solution. Due to its high purity the synthetic AC had a very low and reproducible fluorine blank (0.3 μg/g) compared to natural ACs (up to approximately 9 μg/g). Using this AC, fluoride and the internal standard phosphate could be detected free of chromatographic interferences. With a sample volume of 100 mL and 2× 100 mg of AC packed into two extraction columns combined in series, a limit of quantification (LOQ), derived according to the German standard method DIN 32645, of 0.3 μg/L was achieved. The recoveries of six model PFCs were determined from tap water and a municipal wastewater treatment plant (WWTP) effluent. Except for the extremely polar perfluoroacetic acid (recovery of approximately 10%) the model substances showed fairly good (50% for perfluorobutanoic acid (PFBA)) to very good fluorine recoveries (100±20% for perfluorooctanoic acid (PFOA), perfluorobutanesulfonate (PFBS), 6:2 fluorotelomersulfonate (6:2 FTS)), both from tap water and wastewater matrix. This new analytical protocol was exemplarily applied to several surface water and groundwater samples. The obtained AOF values were compared to the fluorine content of 19 target PFCs analyzed by high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-(-)ESI-MS/MS). In groundwater contaminated by PFC-containing aqueous film-forming foams (AFFFs) up to 50% of the AOF could be attributed to PFC target chemicals, while in diffuse contaminated samples only <5% of the AOF could be identified by PFC analysis.

[1]  Mark J. Strynar,et al.  Polyfluorinated compounds: past, present, and future. , 2011, Environmental science & technology.

[2]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[3]  F. Koczy,et al.  IMPREGNATION OF GLASS SURFACE AGAINST SORPTION OF PHOSPIIATE TRACES , 1963 .

[4]  F. Lange,et al.  Occurrence of perfluoroalkyl sulfonates and carboxylates in German drinking water sources compared to other countries. , 2007, Water science and technology : a journal of the International Association on Water Pollution Research.

[5]  P. Rumsby,et al.  Perfluorooctane sulphonate and perfluorooctanoic acid in drinking and environmental waters , 2009, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[6]  Pim de Voogt,et al.  Perfluorinated compounds in infiltrated river rhine water and infiltrated rainwater in coastal dunes. , 2010, Environmental science & technology.

[7]  H. Sontheimer,et al.  Zur summarischen Erfassung organischer Halogen- und Schwefelverbindungen in Wässern , 1983 .

[8]  Pawel Rostkowski,et al.  Determination of trace levels of total fluorine in water using combustion ion chromatography for fluorine: a mass balance approach to determine individual perfluorinated chemicals in water. , 2007, Journal of chromatography. A.

[9]  J. A. Camargo Fluoride toxicity to aquatic organisms: a review. , 2003, Chemosphere.

[10]  M. Trojanowicz,et al.  Determination of fluoride as fluorosilane derivative using reversed-phase HPLC with UV detection for determination of total organic fluorine. , 2010, Journal of separation science.

[11]  Dirk Löffler,et al.  Transformation of the X-ray contrast medium iopromide in soil and biological wastewater treatment. , 2008, Environmental science & technology.

[12]  C. Lau,et al.  Perfluoroalkyl acids: a review of monitoring and toxicological findings. , 2007, Toxicological sciences : an official journal of the Society of Toxicology.

[13]  M. Trojanowicz,et al.  Determination of Total Organic Fluorine (TOF) in environmental samples using flow-injection and chromatographic methods , 2011 .

[14]  M. Schmid,et al.  Die Bestimmung geringster Mengen von Phosphation im Wasser von Binnenseen , 1965, Schweizerische Zeitschrift für Hydrologie.

[15]  H. Emmerich,et al.  Simulation of adsorption processes on the glass surface in aqueous solutions containing oxalic acid , 2010 .

[16]  D. Barceló,et al.  Polyfluorinated Chemicals and Transformation Products , 2012 .

[17]  N. N. Greenwood,et al.  Chemistry of the elements , 1984 .

[18]  Manfred Wagner,et al.  Multistep approach for the structural identification of biotransformation products of iodinated X-ray contrast media by liquid chromatography/hybrid triple quadrupole linear ion trap mass spectrometry and (1)H and (13)C nuclear magnetic resonance. , 2009, Analytical chemistry.

[19]  Lyn Denison,et al.  Stockholm Convention on Persistent Organic Pollutants , 2013 .

[20]  R. Letcher,et al.  Monitoring of perfluorinated compounds in aquatic biota: an updated review. , 2011, Environmental science & technology.

[21]  Jennifer A Field,et al.  Quantitative determination of fluorotelomer sulfonates in groundwater by LC MS/MS. , 2004, Environmental science & technology.