Does ST analysis have a place in electronic fetal monitoring?

Abstract Intrapartum cardiotocography (CTG) has a high false-positive rate. This has contributed to the rapid increase in obstetric interventions without a strong improvement in perinatal outcomes. We explore the role of ST analysis (STAN®) as an adjunct to CTG in identifying fetal asphyxia during labor. We conclude that STAN® reduces the rate of fetal blood sampling and instrumental vaginal deliveries, and has the potential to reduce the number of Australian operative interventions without compromising neonatal outcome.

[1]  I. Amer-Wåhlin,et al.  Combined cardiotocographic and ST event analysis: A review. , 2016, Best practice & research. Clinical obstetrics & gynaecology.

[2]  J. V. D. van der Post,et al.  Intrapartum and neonatal mortality in primary midwife-led and secondary obstetrician-led care in the Amsterdam region of the Netherlands: A retrospective cohort study. , 2016, Midwifery.

[3]  Dwight J Rouse,et al.  A Randomized Trial of Intrapartum Fetal ECG ST-Segment Analysis. , 2015, The New England journal of medicine.

[4]  C. East,et al.  Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. , 2015, The Cochrane database of systematic reviews.

[5]  Matthew Hogg,et al.  ST analysis for intrapartum fetal monitoring , 2015 .

[6]  M. Parker,et al.  Australia's mothers and babies 2012 , 2014 .

[7]  D. Ayres-de-Campos,et al.  A critical appraisal of the evidence for using cardiotocography plus ECG ST interval analysis for fetal surveillance in labor. Part II: the meta-analyses , 2014, Acta obstetricia et gynecologica Scandinavica.

[8]  D. Ayres-de-Campos,et al.  A critical appraisal of the evidence for using cardiotocography plus ECG ST interval analysis for fetal surveillance in labor. Part I: the randomized controlled trials , 2014, Acta obstetricia et gynecologica Scandinavica.

[9]  G. Saade,et al.  Effectiveness of electronic fetal monitoring with additional ST analysis in vertex singleton pregnancies at >36 weeks of gestation: an individual participant data metaanalysis. , 2013, American journal of obstetrics and gynecology.

[10]  U. Hanson,et al.  Fetal monitoring with computerized ST analysis during labor: a systematic review and meta‐analysis , 2012, Acta obstetricia et gynecologica Scandinavica.

[11]  J. Neilson,et al.  Fetal electrocardiogram (ECG) for fetal monitoring during labour. , 2013, The Cochrane database of systematic reviews.

[12]  Z. Alfirevic,et al.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. , 2006, The Cochrane database of systematic reviews.

[13]  K. Shibuya,et al.  No cry at birth: global estimates of intrapartum stillbirths and intrapartum-related neonatal deaths. , 2005, Bulletin of the World Health Organization.

[14]  I. Amer-Wåhlin,et al.  Implementation of new medical techniques: Experience from the Swedish randomized controlled trial on fetal ECG during labor , 2005, The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians.

[15]  Australia's mothers and babies. , 1995, Australian health review : a publication of the Australian Hospital Association.

[16]  H. Jenkins Thirty Years of Electronic Intrapartum Fetal Heart Rate Monitoring: Discussion Paper , 1989, Journal of the Royal Society of Medicine.

[17]  R. Goodlin,et al.  History of fetal monitoring. , 1979, American journal of obstetrics and gynecology.

[18]  G. M. Filshie,et al.  THE SIGNIFICANCE OF THE CHANGES IN THE CONTINUOUS FETAL HEART RATE IN THE FIRST STAGE OF LABOUR , 1971, The Journal of obstetrics and gynaecology of the British Commonwealth.