Sensitivity Analysis of Broadband On-Wafer Dielectric Spectroscopy of Yeast Cell Suspensions up to 110 GHz

This letter presents broadband on-wafer dielectric spectroscopy of baker's yeast cell suspensions up to 110 GHz. A detailed analysis of the sensitivities to measurement repeatability and uncertainties in the multi-step de-embedding procedure is performed. The Cole-Cole dispersion parameters of the cell suspensions are obtained from measured complex permittivity data between 0.5 and 110 GHz. Our analysis shows that the measured complex permittivity per frequency is most sensitive to length uncertainties of the test fixture, while the relaxation time in the Cole-Cole model is most sensitive to measurement repeatability.

[1]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[2]  V. Krozer,et al.  EM simulation accuracy enhancement for broadband modeling of on-wafer passive components , 2007, 2007 European Microwave Integrated Circuit Conference.

[3]  A. Oleinikova,et al.  What Can Really Be Learned from Dielectric Spectroscopy of Protein Solutions? A Case Study of Ribonuclease A , 2004 .

[4]  T. Fujii,et al.  Integrated Broadband Microwave and Microfluidic Sensor Dedicated to Bioengineering , 2009, IEEE Transactions on Microwave Theory and Techniques.

[5]  David Dubuc,et al.  Microwave signatures of alive B-lymphoma cells suspensions , 2011, 2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems.

[6]  D. Schreurs,et al.  Millimeter wave on-wafer measurement of yeast cell suspension using a CPW test fixture in LCP technology , 2013, 82nd ARFTG Microwave Measurement Conference.

[7]  Michael D. Janezic,et al.  Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz , 2010, IEEE Transactions on Instrumentation and Measurement.

[8]  Jung-Mu Kim,et al.  In vitro and in vivo measurement for biological applications using micromachined probe , 2005, IMS 2005.

[9]  W. J. Ellisona Permittivity of Pure Water, at Standard Atmospheric Pressure, over the Frequency Range 0–25 THz and the Temperature Range 0–100 °C , 2007 .

[10]  K. Foster,et al.  RF-field interactions with biological systems: Electrical properties and biophysical mechanisms , 1980, Proceedings of the IEEE.

[11]  D. Schreurs,et al.  Broadband dielectric spectroscopy calibration for microliter samples of biogenic liquid , 2014, 2014 44th European Microwave Conference.