Radiation-Induced Attenuation of Perfluorinated Polymer Optical Fibers for Radiation Monitoring

Due to some of their unique properties, optical fiber dosimeters are attractive and extensively researched devices in several radiation-related areas. This work evaluates the performance and potential of commercial perfluorinated polymer optical fibers (PF-POFs) for radiation monitoring applications. Gamma radiation-induced attenuation (RIA) of two commercial PF-POFs is evaluated in the VIS spectral region. Influence of a dose rate and temperature on RIA measurement is investigated, along with defect stability and measurement repeatability. Co-extruded PF-POFs are identified as more suitable for radiation monitoring applications due to lower dose-rate dependence. With co-extruded PF-POF, RIA measurement holds potential for highly-sensitive radiation monitoring with good reproducibility. The results show that operation in the blue part of the spectrum provides most favorable performance in terms of the largest nominal radiation sensitivity, lower temperature, and dose-rate dependence as well as higher defect stability. We demonstrate for the first time to our knowledge, that PF-POFs can be used for distributed detection of radiation with doses down to tens of Grays. The off-the-shelf, user-friendly PF-POF could be of interest as a cheap, disposable sensor for various applications, especially of a more qualitative nature.

[1]  O. Ziemann,et al.  POF Handbook: Optical Short Range Transmission Systems , 2008 .

[2]  Elfed Lewis,et al.  A review of optical fibre radiation dosimeters , 2008 .

[3]  Katerina Krebber,et al.  Effects of gamma radiation on perfluorinated polymer optical fibers , 2016 .

[4]  P. Woulfe,et al.  Plastic optical fibre sensor for in-vivo radiation monitoring during brachytherapy , 2015, International Conference on Optical Fibre Sensors.

[5]  Elfed Lewis,et al.  Polymer Optical Fibre for in Situ Monitoring of Gamma Radiation Processes , 2009 .

[6]  E. Lewis,et al.  Radiotherapy dosimetry based on plastic optical fibre sensors , 2013, Other Conferences.

[7]  Fabrizio Di Pasquale,et al.  Distributed Optical Fiber Radiation Sensing in a Mixed-Field Radiation Environment at CERN , 2017, Journal of Lightwave Technology.

[8]  Anirban Dhar,et al.  Radiation response behavior of high phosphorous doped step-index multimode optical fibers under low dose gamma irradiation , 2009 .

[9]  Elfed Lewis,et al.  Real-time gamma dosimetry using PMMA optical fibres for applications in the sterilization industry , 2007 .

[10]  C. Loyez,et al.  Exploit the Bandwidth Capacities of the Perfluorinated Graded Index Polymer Optical Fiber for Multi-Services Distribution , 2011 .

[11]  E. Friebele Optical Fiber Waveguides In Radiation Environments , 1979 .

[12]  Elfed Lewis,et al.  Optical fibers and optical fiber sensors used in radiation monitoring , 2012 .

[13]  Youcef Ouerdane,et al.  Feasibility of radiation dosimetry with phosphorus-doped optical fibers in the ultraviolet and visible domain , 2011 .

[14]  H. Henschel,et al.  Optical fibres as radiation dosimeters , 1992 .

[15]  A. L. Tomashuk,et al.  Comparison of Gamma-Radiation Induced Attenuation in Al-Doped, P-Doped and Ge-Doped Fibres for Dosimetry , 2013, IEEE Transactions on Nuclear Science.

[16]  J. Rolland,et al.  Low dose plastic optical fibre radiation dosimeter for clinical dosimetry applications , 2009, 2009 IEEE Sensors.

[17]  M. D. Rourke,et al.  Optical time domain reflectometer. , 1977, Applied optics.

[18]  Yasuhiro Koike Fundamentals of Plastic Optical Fibers , 2014 .

[19]  Laura Mihai,et al.  A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy. , 2015, The British journal of radiology.

[20]  K. Krebber,et al.  Towards on-line radiation monitoring with perfluorinated polymer optical fibers , 2017, 2017 25th Optical Fiber Sensors Conference (OFS).

[21]  Katerina Krebber,et al.  Radiation induced attenuation in perfluorinated polymer optical fibres for dosimetry applications , 2016 .

[22]  Alan L. Huston,et al.  Remote optical fiber dosimetry , 2001 .

[23]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[24]  H. Henschel,et al.  Fibre optic radiation sensor systems for particle accelerators , 2004 .

[25]  S. Girard,et al.  Radiation Effects on Silica-Based Optical Fibers: Recent Advances and Future Challenges , 2013, IEEE Transactions on Nuclear Science.