Assessment of Exposure to Electric Vehicle Inductive Power Transfer Systems: Experimental Measurements and Numerical Dosimetry

High-power inductive power transfer (IPT) systems for charging light and heavy electric vehicles pose safety concerns if they are installed in uncontrolled environments. Within the framework of the European Project EMPIR-16ENG08 MICEV, a wide experimental and numerical study was conducted to assess the exposure of the general public to IPT stray magnetic fields for two different exposure scenarios: (1) for an IPT model system derived from the SAE J2954 standard operating at 85 kHz for a light electric vehicle coupled with the model of a realistic car-body model; and (2) for an IPT model system with a maximum rated power of 50 kW at 27.8 kHz for a real minibus that was reproduced with some simplifications in two different 3D finite element method (FEM) simulation tools (Opera 3D and CST software). An ad hoc measurement survey was carried out at the minibus charging station to validate the simulations of the real bus station for both aligned and misaligned IPT coils. Based on this preliminary study, a safety factor was chosen to ensure a conservative dosimetric analysis with respect to the model approximations. As highlighted in this study, the vehicle-body serves as an efficient screen to reduce the magnetic field by at least three orders of magnitude close to the coils. By applying FEM, computed spatial distribution to the Sim4Life software, the exposure of three Virtual Population human anatomical phantoms (one adult, one child, and a newborn) was assessed. The three phantoms were placed in different postures and locations for both exposure scenarios. The basic restriction limits, established by the current guidelines, were never exceeded within the vehicles; however, the basic restrictions were exceeded when an adult crouched outside the minibus, i.e., near the coils, or when a newborn was placed in the same location. Borderline values were observed in the light car. In the case of the bus, limits coming from the Institute of Electrical and Electronics Engineers (IEEE) guidelines are never exceeded, while basic restrictions coming from the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines are exceeded up to 12% for an adult and up to 38% for a newborn. This paper presents novel dosimetric data generated in an IPT system for heavy vehicles and confirms some of the literature data on light vehicles.

[1]  Xueliang Huang,et al.  Human Exposure to Electromagnetic Fields from Parallel Wireless Power Transfer Systems , 2017, International journal of environmental research and public health.

[2]  Andreas Christ,et al.  Assessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems , 2013, Proceedings of the IEEE.

[3]  K. Jokela,et al.  ICNIRP Guidelines GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING , 1998 .

[4]  J. Herbertz Comment on the ICNIRP guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998, Health physics.

[5]  Adel El-Shahat,et al.  Electric Vehicles Wireless Power Transfer State-of-The-Art , 2019, Energy Procedia.

[6]  Akimasa Hirata,et al.  Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle. , 2013, Physics in medicine and biology.

[7]  Luca Giaccone,et al.  Accuracy Assessment of Numerical Dosimetry for the Evaluation of Human Exposure to Electric Vehicle Inductive Charging Systems , 2020, IEEE Transactions on Electromagnetic Compatibility.

[8]  Akimasa Hirata,et al.  In-situ electric field in human body model in different postures for wireless power transfer system in an electrical vehicle. , 2015, Physics in medicine and biology.

[9]  A. Llombart,et al.  Design of a high frequency Inductively Coupled Power Transfer system for electric vehicle battery charge , 2009 .

[10]  Niels Kuster,et al.  Methodology of detailed dosimetry and treatment of uncertainty and variations for in vivo studies , 2006, Bioelectromagnetics.

[11]  Sangwook Park Evaluation of Electromagnetic Exposure During 85 kHz Wireless Power Transfer for Electric Vehicles , 2018, IEEE transactions on magnetics.

[12]  Tommaso Campi,et al.  Assessment of the Induced Electric Fields in a Carbon-Fiber Electrical Vehicle Equipped with a Wireless Power Transfer System , 2018 .

[13]  Niels Kuster,et al.  Novel Method and Procedure for Evaluating Compliance of Sources With Strong Gradient Magnetic Fields Such as Wireless Power Transfer Systems , 2020, IEEE Transactions on Electromagnetic Compatibility.

[14]  Mario Chiampi,et al.  Set Up and Characterization of a System for the Generation of Reference Magnetic Fields From 1 to 100 kHz , 2007, IEEE Transactions on Instrumentation and Measurement.

[15]  Niels Kuster,et al.  Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0 , 2014, Physics in medicine and biology.

[16]  Quandi Wang,et al.  Electromagnetic Safety Evaluation and Protection Methods for a Wireless Charging System in an Electric Vehicle , 2019, IEEE Transactions on Electromagnetic Compatibility.

[17]  Young Jae Jang,et al.  Survey of the operation and system study on wireless charging electric vehicle systems , 2018, Transportation Research Part C: Emerging Technologies.

[18]  M. Repetto,et al.  Human exposure assessment in dynamic inductive power transfer for automotive applications , 2016, 2016 IEEE Conference on Electromagnetic Field Computation (CEFC).

[19]  Niels Kuster,et al.  The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulations , 2010, Physics in medicine and biology.

[20]  Kanako Wake,et al.  Exposure Evaluation of an Actual Wireless Power Transfer System for an Electric Vehicle With Near-Field Measurement , 2018, IEEE Transactions on Microwave Theory and Techniques.

[21]  Akimasa Hirata,et al.  Electromagnetic Dosimetry and Compliance for Wireless Power Transfer Systems in Vehicles , 2019, IEEE Transactions on Electromagnetic Compatibility.

[22]  M. Soljačić,et al.  Wireless Power Transfer via Strongly Coupled Magnetic Resonances , 2007, Science.