The effect on intracuff pressure of various nitrous oxide concentrations used for inflating an endotracheal tube cuff.

UNLABELLED We sought to determine the optimal concentration of nitrous oxide (N(2)O) for inflating endotracheal tube cuffs, to avoid overinflation and air leaks. Female patients undergoing endotracheal intubation (inner diameter 7.5 mm) during anesthesia with 67% N(2)O were randomly assigned to five groups of 25 subjects each, in which cuffs were inflated with 0% (Air), 30% (N30), 40% (N40), 50% (N50), or 67% (N67) N(2)O. The cuff pressure and the N(2)O concentration in the cuff were measured. In an additional 15 patients (N40-a group), pilot balloons were replaced with metal tubes, and the mouths and noses of the patients were wrapped with tape, to minimize N(2)O efflux into the air. Postoperative sore throats were evaluated in double-blinded interviews. Cuff pressures increased significantly in the Air and N30 groups but decreased in the N67 group. Cuff pressures were <22 mm Hg in the N40 and N50 groups, but the N50 group had air leaks. The N(2)O concentration in the cuff in the N40 group was significantly smaller than that in the N40-a group, suggesting N(2)O rediffusion. The incidence of sore throats (40% in the Air group) was reduced significantly in the N40 and N50 groups. Therefore, 40% N(2)O is optimal for filling the cuff during anesthesia with 67% N(2)O. IMPLICATIONS Nitrous oxide (N(2)O) diffuses into the cuff, equilibrating at a smaller concentration than the gas mixture with which patients are ventilated. Our data indicate that inflation of the cuff with 40% N(2)O is recommended to prevent both excessive endotracheal cuff pressure and air leaks during anesthesia with 67% N(2)O, reducing postoperative sore throats.

[1]  M. Fujiwara,et al.  A New Endotracheal Tube with a Cuff Impervious to Nitrous Oxide: Constancy of Cuff Pressure and Volume , 1995, Anesthesia and analgesia.

[2]  Dosch Mp,et al.  Rediffusion of nitrous oxide prevents increases in endotracheal tube cuff pressure. , 1994 .

[3]  M. R. Bruni,et al.  Rediffusion of nitrous oxide prevents increases in endotracheal tube cuff pressure. , 1994, AANA journal.

[4]  J. Benumof,et al.  The Resting Volume and Compliance Characteristics of the Bronchial Cuff of Left Polyvinyl Chloride Double‐Lumen Endobronchial Tubes , 1993, Anesthesia and analgesia.

[5]  J. Benumof,et al.  Comparison of Three Techniques to Inflate the Bronchial Cuff of Left Polyvinylchloride Double‐Lumen Tubes , 1993, Anesthesia and analgesia.

[6]  D. Miller,et al.  The Miller tracheal cuff pressure control valve , 1993, Anaesthesia.

[7]  M. el Hakim Beclomethasone prevents postoperative sore throat. , 1993, Acta anaesthesiologica Scandinavica.

[8]  L. Nikolajsen,et al.  Sore Throat After Endotracheal Intubation , 1992, Anesthesia and analgesia.

[9]  N. Gravenstein,et al.  Postoperative Sore Throat: Effect of Oropharyngeal Airway in Orotracheally Intubated Patients , 1990, Anesthesia and analgesia.

[10]  J. Katz,et al.  A modified epidural syringe as an endotracheal tube cuff pressure-controlling device. , 1990, Anesthesia and analgesia.

[11]  M. Bishop,et al.  Correlation of endotracheal tube size with sore throat and hoarseness following general anesthesia. , 1987, Anesthesiology.

[12]  J. Raeder,et al.  Tracheal tube cuff pressures , 1985, Anaesthesia.

[13]  S. Mehta,et al.  The cross-sectional shape and circumference of the human trachea. , 1984, Annals of the Royal College of Surgeons of England.

[14]  R. Seegobin,et al.  Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. , 1984, British medical journal.

[15]  H. Turndorf,et al.  Succinylcholine-induced Postoperative Sore Throat , 1983, Anesthesiology.

[16]  L. Brandt,et al.  [The rediffusion system. Limitation of nitrous oxide increases the cuff pressure of endotracheal tubes]. , 1983, Der Anaesthesist.

[17]  N. Pace,et al.  The influence of endotracheal tube cuff design and cuff lubrication on postoperative sore throat. , 1983, Anesthesiology.

[18]  E. Zook,et al.  Lubrication of tracheal tubes to prevent sore throat from intubation , 1982, Anesthesiology.

[19]  S. Borgeskov,et al.  A new tracheostomy tube. III. Bronchofiberoptic examination of the trachea after prolonged intubation with the NL tracheostomy tube. , 1981, Acta anaesthesiologica Scandinavica.

[20]  J. M. Kim The tracheal tube cuff pressure stabilizer and its clinical evaluation. , 1980, Anesthesia and analgesia.

[21]  U Nordin,et al.  The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention. , 1977, Acta oto-laryngologica. Supplementum.

[22]  T. Stanley,et al.  Tracheostomy and endotracheal tube cuff volume and pressure changes during thoracic operations. , 1975, The Annals of thoracic surgery.

[23]  T. Stanley,et al.  Effects of nitrous oxide on volume and pressure of endotracheal tube cuffs. , 1974, Anesthesiology.

[24]  T. Stanley,et al.  Comparison of Blood Requirements during Morphine and Halothane Anesthesia for Open‐heart Surgery , 1974, Anesthesiology.

[25]  R. Carroll,et al.  Performance Characteristics of Tracheal Cuffs , 1974, International anesthesiology clinics.

[26]  N. Lomholt A NEW TRACHEOSTOMY TUBE , 1967 .

[27]  I. Bross How to use Ridit Analysis , 1958 .