The resistive and capacitive properties of stainless-steel electrodes in contact with saline solutions of various concentrations were investigated over a frequency range extending from 20 to 10 kHz by using a variable-length conductivity cell. With a low current density, the series-equivalent resistance and capacitance of a single electrode-electrolyte interface were found to vary almost inversely as the square root of frequency. In the frequency range studied, it was found that the reactance was very nearly equal to the resistance and both varied almost inversely as the square root of the frequency, verifying Warburg's postulate. When current density was increased, resistance decreased and capacitance increased at all frequencies studied; the change in each was most apparent in the low frequency region. As a consequence, it can be stated that the impedance of an electrode-electrolyte interface decreases with increasing current density.SommaireLes propriétés résistives et capacitives des électrodes inoxydables en contact avec des solutions salines de concentrations variées, ont été investiguées sur une rangée de fréquences s'étendant de 20 jusqu'à 10 kHz, en utilisant une cellule de conductivité de longueur variable. Avec une densité basse de courant, la résistance et la capacitance équivalente de séries, d'une seule interface de l'électrode-électrolyte ont été trouvées de varier presque inversement à la racine carrée de la fréquence, Dans la rangée de fréquences étudiées, on a trouvé que la réactance était presque égale à la résistance et les deux ont varié presque inversement, comme la racine carrée de la fréquence, vérifiant ainsi le postulat de Warburg. Quand la densité du courant fût augmentée, la résistance décrût et la capacitance augmenta dans toutes les fréquences étudiées; le changement dans chaque fréquence était le plus apparent dans la région basse de fréquence. Par conséquent, on peut affirmer que l'impédance d'une interface électrode-électrolyte décroît avec la densité croissante du courant.ZusammenfassungEs wurden die Widerstands- und Kapazitätseigenschaften von Elektroden aus rostfreiem Stahl in Kontakt mit Salzlösungen verschiedener Konzentrationen über einem Frequenzbereich von 20 bis zu 10 kHz bei Verwendung von einer Leitfähigkeitzelle mit veränderlicher Länge untersucht. Es wurde festgestellt, dass mit einer niedrigen Stromdichte Reihenäquivalent von Widerstand und Kapazität einer Einzelelektroden-Elektrolytengrenzfläche sich beinahe umgekehrt mit der Quadratwurzel der Frequenz ändert. Es wurde bei dem untersuchten Frequenzbereich festgestellt, dass die Reaktanz fast ganz gleich dem Widerstand war, und dass beide sich fast umgekehrt mit der Quadratwurzel der Frequenz änderten und Warburg's Grundbedingung bestätigten. Wenn die Stromdichte vergrössert wurde, nahm der Widerstand ab und die Kapazität nahm bei allen untersuchten Frequenzen zu. Die Änderung in Beiden war am meisten im niedrigen Frequenzbereich bemerkbar. Es kann somit behauptet werden, dass die Impedanz einer Elektroden-Elektrolytengrenzfläche mit zunehmender Stromdichte abnimmt.
[1]
L. E. Baker,et al.
The relationship between input impedance and electrode area in recording the ECG
,
2006,
Medical and biological engineering.
[2]
H. Fricke,et al.
XXXIII. The theory of electrolytic polarization
,
1932
.
[3]
J. Weinman,et al.
An analysis of electrical properties of metal electrodes
,
1964,
Medical electronics and biological engineering.
[4]
H P Schwan,et al.
ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS *
,
1968,
Annals of the New York Academy of Sciences.
[5]
Robert Kennedy.
L. Chemical analysis of an uncommon species of zeolite
,
1803
.
[6]
H. Helmholtz,et al.
Studien über electrische Grenzschichten
,
1879
.
[7]
Herman P. Schwan,et al.
CHAPTER 6 – DETERMINATION OF BIOLOGICAL IMPEDANCES1
,
1963
.
[8]
The relationship between electrode area and amplifier input impedance in recording muscle action potentials
,
1967,
Medical and biological engineering.
[9]
Max Wien,et al.
Ueber die Polarisation bei Wechselstrom
,
1896
.
[10]
D B Geselowitz,et al.
Nonlinearity of cardiac pacemaker electrodes.
,
1969,
IEEE transactions on bio-medical engineering.
[11]
M. Gouy,et al.
Sur la constitution de la charge électrique à la surface d'un électrolyte
,
1910
.
[12]
E. Warburg,et al.
Ueber das Verhalten sogenannter unpolarisirbarer Elektroden gegen Wechselstrom
,
1899
.
[13]
E. Warburg,et al.
Ueber die Polarisationscapacität des Platins
,
1901
.
[14]
D. Hubel.
Tungsten Microelectrode for Recording from Single Units.
,
1957,
Science.
[15]
D. Grahame,et al.
Fiftieth Anniversary: Mathematical Theory of the Faradaic Admittance Pseudocapacity and Polarization Resistance
,
1952
.
[16]
Harry Grundfest,et al.
ORIGIN, CONDUCTION AND TERMINATION OF IMPULSES IN THE DORSAL SPINO-CEREBELLAR TRACT OF CATS
,
1942
.
[17]
R. Spitzer.
Untersuchungen über die Gewöhnung von Gonokokken an Sulfanilamide (Cibazol und Sulfanilamid) und andere Bakteriengifte (Trypaflavin und Oxycyanat) im Kulturexperiment.
,
1942
.
[18]
O. Stern.
ZUR THEORIE DER ELEKTROLYTISCHEN DOPPELSCHICHT
,
1924,
Zeitschrift für Elektrochemie und angewandte physikalische Chemie.
[19]
Harry Grundfest,et al.
Stainless Steel Micro‐Needle Electrodes Made by Electrolytic Pointing
,
1950
.