Glucose oxidase/polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensor
暂无分享,去创建一个
Soichi Yabuki | Yukari Sato | Fumio Mizutani | Yoshiki Hirata | Yukari Sato | F. Mizutani | S. Yabuki | T. Sawaguchi | Y. Hirata | Takahiro Sawaguchi
[1] Alexander M. Yacynych,et al. Electropolymerized films to prevent interferences and electrode fouling in biosensors , 1991 .
[2] Soichi Yabuki,et al. Enzyme Ultra-thin Layer Electrode Prepared by the Co-adsorption of Poly-L-lysine and Glucose Oxidase onto a Mercaptopropionic Acid-Modified Gold Surface , 1996 .
[3] G. S. Wilson,et al. Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors. , 1996, Analytical chemistry.
[4] P. Zambonin,et al. An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling , 1993 .
[5] F. Mizutani,et al. Carbon paste electrode incorporated with cobalt(II) octaethoxyphthalocyanine for the amperometric detection of hydrogen peroxide , 1995 .
[6] Alexander M. Yacynych,et al. Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors , 1990 .
[7] F. Mizutani,et al. Simultaneous determination of glucose and sucrose by a glucose-sensing enzyme electrode combined with an invertase-attached cell , 1990 .
[8] Soichi Yabuki,et al. AMPEROMETRIC L-LACTATE-SENSING ELECTRODE USING AN ENZYME ULTRA-THIN LAYER PRODUCED THROUGH THE CO-ADSORPTION OF POLY-L-LYSINE AND LACTATE OXIDASE ONTO MERCAPTOALKANOIC ACID-MODIFIED GOLD SURFACE , 1996 .
[9] F. Mizutani,et al. Flow injection analysis of L-lactic acid using an enzyme-polyion complex-coated electrode as the detector. , 1996, Talanta.
[10] Brian L. Frey,et al. Characterization of poly-L-lysine adsorption onto alkanethiol-modified gold surfaces with polarization-modulation Fourier transform infrared spectroscopy and surface plasmon resonance measurements , 1994 .
[11] D. J. Harrison,et al. Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. , 1988, Analytical chemistry.
[12] Soichi Yabuki,et al. Amperometric Alcohol-Sensing Electrode Based on a Polyion Complex Membrane Containing Alcohol Oxidase , 1997 .
[13] Y. Osajima,et al. Ascorbate electrode for determination of L-ascorbic acid in food. , 1981, Analytical chemistry.
[14] J. Lowry,et al. Strategies for reducing ascorbate interference at glucose oxidase modified conducting organic salt electrodes , 1992 .
[15] A. Turner,et al. Glucose oxidase: an ideal enzyme , 1992 .
[16] A. Lewenstam,et al. Elimination of interferences in flow‐injection amperometric determination of glucose in blood serum using immobilized glucose oxidase , 1990 .
[17] G. S. Wilson,et al. Elimination of the acetaminophen interference in an implantable glucose sensor. , 1994, Analytical chemistry.
[18] Soichi Yabuki,et al. Amperometric l-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples , 1995 .
[19] Alexander M. Yacynych,et al. Use of polymer films in amperometric biosensors , 1995 .
[20] Marco F. Cardosi,et al. Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase , 1993 .
[21] Y. Osajima,et al. Simultaneous determination of glucose, fructose, and sucrose in mixtures by amperometric flow injection analysis with immobilized enzyme reactors. , 1988, Analytical chemistry.
[22] D. Centonze,et al. Permeation of solutes through an electropolymerized ultrathin poly‐o‐phenylenediamine film used as an enzyme‐entrapping membrane , 1994 .
[23] F. Mizutani,et al. Amperometric enzyme electrode with fast response to glucose using a layer of lipid-modified glucose oxidase and Nafion anionic polymer , 1993 .
[24] K. Kataoka,et al. Effect of charge and molecular structure of polyion complexes on the morphology of adherent blood platelets , 1978 .
[25] F. Mizutani,et al. Amperometric Biosensors Using Poly-L-Lysine/Poly (styrenesulfonate) Membranes with Immobilized Enzymes , 1995 .
[26] Antonio Guerrieri,et al. Interference-free glucose sensor based on glucose-oxidase immobilized in an overoxidized non-conducting polypyrrole film , 1992 .
[27] F. Mizutani,et al. Rapid determination of glucose and sucrose by an amperometric glucose-sensing electrode combined with an invertase/mutarotase-attached measuring cell , 1997 .