THINK surgical TSolution-One® (Robodoc) total knee arthroplasty

THINK Surgical TSolution-One® is an active-autonomous, image-based, robotic milling system which enables the surgeon to attain a consistently accurate implant component positioning. The TSolution-One® system is capable of achieving this through an image-based preoperative planning system which allows the surgeon to create, view and analyse the surgical outcome in 3D. The accuracy and precision of component positioning have been attributed to the following factors: customized distal femoral resection, accurate determination of the femoral rotational alignment, minimization of errors and maintenance of bone temperature with robotic milling. Despite all these advantages, there is still a paucity of long-term, high-quality data that demonstrates the efficacy of robotic-assisted total knee arthroplasty (TKA). Questions regarding radiation risks, prolonged surgical duration and cost-effectiveness remain unanswered. This paper aims to describe: (1) TSolution-One® surgical technique; (2) limitations and complications; (3) clinical and radiological outcomes.

[1]  D. Miglioretti,et al.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. , 2009, Archives of internal medicine.

[2]  R. Laskin,et al.  Prolonged Operative Time Correlates with Increased Infection Rate After Total Knee Arthroplasty , 2006, HSS Journal.

[3]  N. Kharwadkar,et al.  Short communication 5- to 6- of distal femoral cut for uncomplicated primary total knee arthroplasty : Is it safe? , 2006 .

[4]  J. Bellemans Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep. , 1999, Acta orthopaedica Scandinavica. Supplementum.

[5]  Michael M Morlock,et al.  Comparison of robotic-assisted and manual implantation of a primary total hip replacement. A prospective study. , 2003, The Journal of bone and joint surgery. American volume.

[6]  Sang Eun Park,et al.  Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. , 2007, The Journal of arthroplasty.

[7]  A. Tavakkolizadeh,et al.  Robotic surgery in trauma and orthopaedics: a systematic review. , 2015, The bone & joint journal.

[8]  M. Ritter,et al.  The effect of alignment and BMI on failure of total knee replacement. , 2011, The Journal of bone and joint surgery. American volume.

[9]  Yoon-Hyuk Kim,et al.  Causes and patterns of aborting a robot-assisted arthroplasty. , 2011, The Journal of arthroplasty.

[10]  Russell H. Taylor,et al.  Development of a Surgical Robot for Cementless Total Hip Arthroplasty , 1992, Clinical orthopaedics and related research.

[11]  M. Liow,et al.  Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system. , 2014, Singapore medical journal.

[12]  G. Goh,et al.  Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial , 2017, Knee Surgery, Sports Traumatology, Arthroscopy.

[13]  K-I Kim,et al.  Robot‐assisted total knee arthroplasty in haemophilic arthropathy , 2016, Haemophilia : the official journal of the World Federation of Hemophilia.

[14]  S. Young,et al.  Periprosthetic Joint Infection Is the Main Cause of Failure for Modern Knee Arthroplasty: An Analysis of 11,134 Knees , 2017, Clinical orthopaedics and related research.

[15]  Johan Bellemans,et al.  Robot-assisted Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.

[16]  Anthony J. Petrella,et al.  Optimizing Femoral Component Rotation in Total Knee Arthroplasty , 2001, Clinical orthopaedics and related research.

[17]  H. Rubash,et al.  Can Robot-Assisted Unicompartmental Knee Arthroplasty Be Cost-Effective? A Markov Decision Analysis. , 2016, The Journal of arthroplasty.

[18]  M P Craven,et al.  Surgeon opinion on new technologies in orthopaedic surgery , 2011, Journal of medical engineering & technology.

[19]  N. Kharwadkar,et al.  5 degrees to 6 degrees of distal femoral cut for uncomplicated primary total knee arthroplasty: is it safe? , 2006, The Knee.

[20]  W. Bargar,et al.  Robotic-assisted TKA Reduces Postoperative Alignment Outliers and Improves Gap Balance Compared to Conventional TKA , 2012, Clinical orthopaedics and related research.

[21]  D. Jacofsky,et al.  Robotics in Arthroplasty: A Comprehensive Review. , 2016, The Journal of arthroplasty.

[22]  M. Conditt,et al.  Robotic Total Knee Arthroplasty: Surgical Assistant for a Customized Normal Kinematic Knee. , 2016, Orthopedics.

[23]  R. Kober,et al.  Technique and first clinical results of robot-assisted total knee replacement. , 2002, The Knee.

[24]  J. Seon,et al.  Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[25]  Khaled J Saleh,et al.  Antibiotic-impregnated cement spacers for the treatment of infection associated with total hip or knee arthroplasty. , 2007, The Journal of bone and joint surgery. American volume.

[26]  R. Morris,et al.  Coronal alignment after total knee replacement. , 1991, The Journal of bone and joint surgery. British volume.

[27]  T Albrektsson,et al.  The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber. , 1984, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[28]  C. Plaskos,et al.  Bone cutting errors in total knee arthroplasty. , 2002, The Journal of arthroplasty.

[29]  M. Ritter,et al.  Tibial Component Failure Mechanisms in Total Knee Arthroplasty , 2004, Clinical orthopaedics and related research.