Design of a line-start synchronous reluctance motor

The design of line-start Synchronous Reluctance machines is proposed, based on the state of the art of motors designed for closed loop, vector control. The guidelines for overcoming the dilemma between synchronization capability and steady state performance are given, with examples of good and bad design choices. The proposed solutions compared via finite element analysis with a competitor induction motor in terms of efficiency and power factor. The finite element calculations are finally validated via experiments on a laboratory prototype.

[1]  K. Shaw,et al.  Synchronous AC motors for process control over wide speed ranges , 1988, IEEE 1988 Annual Textile Industry Technical Conference.

[2]  V. Honsinger Permanent Magnet Machines: Asychronous Operation , 1980, IEEE Transactions on Power Apparatus and Systems.

[3]  K. Kurihara,et al.  High efficiency line-start interior permanent magnet synchronous motors , 2003 .

[4]  G. Pellegrino,et al.  Direct Flux Field-Oriented Control of IPM Drives With Variable DC Link in the Field-Weakening Region , 2009, IEEE Transactions on Industry Applications.

[5]  T. Miller Synchronization of Line-Start Permanent-Magnet AC Motors , 1984, IEEE Transactions on Power Apparatus and Systems.

[6]  Alfredo Vagati,et al.  Design criteria of high performance synchronous reluctance motors , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[7]  S T Boroujeni,et al.  Fast Estimation of Line-Start Reluctance Machine Parameters by Finite Element Analysis , 2011, IEEE Transactions on Energy Conversion.

[8]  R. M. Mathur,et al.  Pull-in criterion for reluctance motors , 1973 .