A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Many important post-acquisition aspects of breast tomosynthesis imaging can impact its clinical performance. Chief among them is the reconstruction algorithm that generates the representation of the three-dimensional breast volume from the acquired projections. But even after reconstruction, additional processes, such as artifact reduction algorithms, computer aided detection and diagnosis, among others, can also impact the performance of breast tomosynthesis in the clinical realm. In this two part paper, a review of breast tomosynthesis research is performed, with an emphasis on its medical physics aspects. In the companion paper, the first part of this review, the research performed relevant to the image acquisition process is examined. This second part will review the research on the post-acquisition aspects, including reconstruction, image processing, and analysis, as well as the advanced applications being investigated for breast tomosynthesis.

[1]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[2]  P. Gilbert Iterative methods for the three-dimensional reconstruction of an object from projections. , 1972, Journal of theoretical biology.

[3]  A. Lent,et al.  Iterative reconstruction algorithms. , 1976, Computers in biology and medicine.

[4]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[5]  G Panayiotakis,et al.  A multiple projection method for digital tomosynthesis. , 1992, Medical physics.

[6]  G Panayiotakis,et al.  A method for selective removal of out-of-plane structures in digital tomosynthesis. , 1993, Medical physics.

[7]  N. Boyd,et al.  The quantitative analysis of mammographic densities. , 1994, Physics in medicine and biology.

[8]  Jeffrey A. Fessler,et al.  Ieee Transactions on Image Processing: to Appear Globally Convergent Algorithms for Maximum a Posteriori Transmission Tomography , 2022 .

[9]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[10]  C J D'Orsi,et al.  Comparison of tomosynthesis methods used with digital mammography. , 2000, Academic radiology.

[11]  C J D'Orsi,et al.  Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography. , 2001, Academic radiology.

[12]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[13]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[14]  M L Giger,et al.  Computerized Detection of Mass Lesions in Digital Breast Tomosynthesis Images Using Two- and Three Dimensional Radial Gradient Index Segmentation , 2004, Technology in cancer research & treatment.

[15]  David Kaeli,et al.  Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method , 2004, SPIE Medical Imaging.

[16]  A. Kapur,et al.  Combination of Digital Mammography with Semi-automated 3D Breast Ultrasound , 2004, Technology in cancer research & treatment.

[17]  Tao Wu,et al.  A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.

[18]  Joseph Y. Lo,et al.  Impulse response analysis for several digital tomosynthesis mammography reconstruction algorithms , 2005, SPIE Medical Imaging.

[19]  Berkman Sahiner,et al.  Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience. , 2005, Radiology.

[20]  Lubomir M. Hadjiiski,et al.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. , 2006, Medical physics.

[21]  Joseph Y. Lo,et al.  Gaussian frequency blending algorithm with matrix inversion tomosynthesis (MITS) and filtered back projection (FBP) for better digital breast tomosynthesis reconstruction , 2006, SPIE Medical Imaging.

[22]  Heang-Ping Chan,et al.  Generalized Filtered Back-Projection Reconstruction in Breast Tomosynthesis , 2006, Digital Mammography / IWDM.

[23]  Ann-Katherine Carton,et al.  Quantification for contrast-enhanced digital breast tomosynthesis , 2006, SPIE Medical Imaging.

[24]  Berkman Sahiner,et al.  Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) on breast phantom data , 2006, SPIE Medical Imaging.

[25]  M. Giger,et al.  Computerized mass detection for digital breast tomosynthesis directly from the projection images. , 2006, Medical physics.

[26]  Tao Wu,et al.  Implementing an iterative reconstruction algorithm for digital breast tomosynthesis on graphics processing hardware , 2006, SPIE Medical Imaging.

[27]  Thomas Mertelmeier,et al.  Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device , 2006, SPIE Medical Imaging.

[28]  D. Kopans,et al.  Voting strategy for artifact reduction in digital breast tomosynthesis. , 2006, Medical physics.

[29]  J. Rakowski,et al.  A comparison of reconstruction algorithms for C-arm mammography tomosynthesis. , 2006, Medical physics.

[30]  Gene Gindi,et al.  Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom , 2006, SPIE Medical Imaging.

[31]  Ying Chen,et al.  Noise power spectrum analysis for several digital breast tomosynthesis reconstruction algorithms , 2006, SPIE Medical Imaging.

[32]  Andrew D. A. Maidment,et al.  Registration of Mammograms and Breast Tomosynthesis Images , 2006, Digital Mammography / IWDM.

[33]  Thomas Mertelmeier,et al.  Adaptation of Image Quality Using Various Filter Setups in the Filtered Backprojection Approach for Digital Breast Tomosynthesis , 2006, Digital Mammography / IWDM.

[34]  N. Hylton,et al.  Diagnostic architectural and dynamic features at breast MR imaging: multicenter study. , 2006, Radiology.

[35]  Stephen J. Glick,et al.  A computer simulation for evaluating dual-energy contrast-enhanced breast tomosynthesis , 2007, SPIE Medical Imaging.

[36]  Serge Muller,et al.  Thick Slices from Tomosynthesis Data Sets: Phantom Study for the Evaluation of Different Algorithms , 2009, Journal of Digital Imaging.

[37]  M. Helvie,et al.  Multi-modality 3D breast imaging with X-Ray tomosynthesis and automated ultrasound , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  Berkman Sahiner,et al.  Application of boundary detection information in breast tomosynthesis reconstruction. , 2007, Medical physics.

[39]  Tor D Tosteson,et al.  Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. , 2007, AJR. American journal of roentgenology.

[40]  Nathan J. Packard,et al.  Glandular segmentation of cone beam breast CT volume images , 2007, SPIE Medical Imaging.

[41]  Bo Zhao,et al.  A computer simulation platform for the optimization of a breast tomosynthesis system. , 2007, Medical physics.

[42]  Walker H. Land,et al.  Deblurring of tomosynthesis images using 3D anisotropic diffusion filtering , 2007, SPIE Medical Imaging.

[43]  Serge Muller,et al.  Dual-energy contrast enhanced digital breast tomosynthesis: concept, method, and evaluation on phantoms , 2007, SPIE Medical Imaging.

[44]  Bernhard Erich Hermann Claus,et al.  3D view weighted cone-beam backprojection reconstruction for digital tomosynthesis , 2007, SPIE Medical Imaging.

[45]  Ann-Katherine Carton,et al.  Initial clinical experience with contrast-enhanced digital breast tomosynthesis. , 2007, Academic radiology.

[46]  Arthur E Burgess,et al.  Signal detection in power-law noise: effect of spectrum exponents. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[47]  D. Kopans,et al.  Regional Admittivity Spectra with Tomosynthesis Images for Breast Cancer Detection , 2008, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[48]  Yibin Zheng,et al.  Limited Angle Dual Modality Breast Imaging , 2004, IEEE Transactions on Nuclear Science.

[49]  Hui Yan,et al.  Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS). , 2007, Medical physics.

[51]  Berkman Sahiner,et al.  Digital tomosynthesis mammography: intra- and interplane artifact reduction for high-contrast objects on reconstructed slices using a priori 3D geometrical information , 2007, SPIE Medical Imaging.

[52]  Ying Chen,et al.  Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications. , 2007, Medical physics.

[53]  Elizabeth A Rafferty,et al.  Digital mammography: novel applications. , 2007, Radiologic clinics of North America.

[54]  E. Miller,et al.  Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography , 2007, Physics in medicine and biology.

[55]  Serge Muller,et al.  Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling , 2007, SPIE Medical Imaging.

[56]  Wei Zhao,et al.  Three-dimensional linear system analysis for breast tomosynthesis. , 2008, Medical physics.

[57]  Simon R. Arridge,et al.  3D Digital Breast Tomosynthesis Using Total Variation Regularization , 2008, Digital Mammography / IWDM.

[58]  Nicolas Duchateau,et al.  Optimization of beam parameters and iodine quantification in dual-energy contrast enhanced digital breast tomosynthesis , 2008, SPIE Medical Imaging.

[59]  Ann-Katherine Carton,et al.  Temporal Subtraction Versus Dual-Energy Contrast-Enhanced Digital Breast Tomosynthesis: A Pilot Study , 2008, Digital Mammography / IWDM.

[60]  David Gur,et al.  Applying a 2D based CAD scheme for detecting micro-calcification clusters using digital breast tomosynthesis images: an assessment , 2008, SPIE Medical Imaging.

[61]  Serge Muller,et al.  Computer-Aided Microcalcification Detection on Digital Breast Tomosynthesis Data: A Preliminary Evaluation , 2008, Digital Mammography / IWDM.

[62]  Gang Wu,et al.  Characterization of Projection Ordering in Iterative Reconstruction Methods for Breast Tomosynthesis , 2008, Digital Mammography / IWDM.

[63]  Berkman Sahiner,et al.  Detection of Masses in Digital Breast Tomosynthesis Mammography: Effects of the Number of Projection Views and Dose , 2008, Digital Mammography / IWDM.

[64]  Berkman Sahiner,et al.  Digital tomosynthesis mammography: improvement of artifact reduction method for high-attenuation objects on reconstructed slices , 2008, SPIE Medical Imaging.

[65]  R A Schmidt,et al.  Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study. , 2008, Medical physics.

[66]  Jennifer A. Harvey,et al.  Tomographic Dual Modality Breast Scanner , 2008, Digital Mammography / IWDM.

[67]  James G. Mainprize,et al.  Sensitivity of Contrast-Enhanced Digital Breast Tomosynthesis to Changes in Iodine Concentration during Acquisition , 2008, Digital Mammography / IWDM.

[68]  John M Boone,et al.  Classification of breast computed tomography data. , 2008, Medical physics.

[69]  Chika Honda,et al.  Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube. , 2008, European journal of radiology.

[70]  Berkman Sahiner,et al.  Computer-aided detection of masses in digital tomosynthesis mammography: comparison of three approaches. , 2008, Medical physics.

[71]  Thomas Mertelmeier,et al.  A Novel Approach for Filtered Backprojection in Tomosynthesis Based on Filter Kernels Determined by Iterative Reconstruction Techniques , 2008, Digital Mammography / IWDM.

[72]  Andrew D. A. Maidment,et al.  Evaluating the Effect of Tomosynthesis Acquisition Parameters on Image Texture: A Study Based on an Anthropomorphic Breast Tissue Software Model , 2008, Digital Mammography / IWDM.

[73]  Ehsan Samei,et al.  Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach. , 2008, Medical physics.

[74]  Gregory Boverman,et al.  Robust Linearized Image Reconstruction for Multifrequency EIT of the Breast , 2008, IEEE Transactions on Medical Imaging.

[75]  Zikuan Chen Histogram partition and interval thresholding for volumetric breast tissue segmentation , 2008, Comput. Medical Imaging Graph..

[76]  Anders Tingberg,et al.  Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings , 2008, European Radiology.

[77]  Ann-Katherine Carton,et al.  Breast percent density estimation from 3D reconstructed digital breast tomosynthesis images , 2008, SPIE Medical Imaging.

[78]  Bo Zhao,et al.  Optimization of Tomosynthesis Acquisition Parameters: Angular Range and Number of Projections , 2008, Digital Mammography / IWDM.

[79]  Emil Y. Sidky,et al.  Practical iterative image reconstruction in digital breast tomosynthesis by non-convex TpV optimization , 2008, SPIE Medical Imaging.

[80]  D. Bluemke,et al.  Dynamic contrast-enhanced MRI of the breast: quantitative method for kinetic curve type assessment. , 2009, AJR. American journal of roentgenology.

[81]  Dominique Van de Sompel,et al.  Robust Joint Entropy Regularization of Limited View Transmission Tomography Using Gaussian Approximations to the Joint Histogram , 2009, IPMI.

[82]  Kyle J. Myers,et al.  Estimating breast tomosynthesis performance in detection tasks with variable-background phantoms , 2009, Medical Imaging.

[83]  Kenneth G. A. Gilhuijs,et al.  Breast tomosynthesis in clinical practice: initial results , 2009, European Radiology.

[84]  Fang-Fang Yin,et al.  Comparing digital tomosynthesis to cone-beam CT for position verification in patients undergoing partial breast irradiation. , 2009, International journal of radiation oncology, biology, physics.

[85]  Erik Fredenberg,et al.  A photon-counting detector for dual-energy breast tomosynthesis , 2009, Medical Imaging.

[86]  Piotr Zygmanski,et al.  Evaluation of radiation dose delivered by cone beam CT and tomosynthesis employed for setup of external breast irradiation. , 2008, Medical physics.

[87]  Bing Ma,et al.  Image registration for detection and quantification of change on digital tomosynthesis mammographic volumes. , 2009, AJR. American journal of roentgenology.

[88]  Andrew D. A. Maidment,et al.  Breast tissue classification in digital breast tomosynthesis images using texture features: a feasibility study , 2009, Medical Imaging.

[89]  D. Bluemke,et al.  Relationship of temporal resolution to diagnostic performance for dynamic contrast enhanced MRI of the breast , 2009, Journal of magnetic resonance imaging : JMRI.

[90]  Thomas Mertelmeier,et al.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis. , 2008, Medical physics.

[91]  Ann-Katherine Carton,et al.  Parenchymal texture analysis in digital breast tomosynthesis for breast cancer risk estimation: a preliminary study. , 2009, Academic radiology.

[92]  Xiaochuan Pan,et al.  Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. , 2009, Medical physics.

[93]  Byung H. Han,et al.  X-ray elastography: A feasibility study , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[94]  Ingrid Reiser,et al.  Comparison of power spectra for tomosynthesis projections and reconstructed images. , 2009, Medical physics.

[95]  Niko Papanikolaou,et al.  The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis , 2009, Journal of applied clinical medical physics.

[96]  Ann-Katherine Carton,et al.  Breast percent density: estimation on digital mammograms and central tomosynthesis projections. , 2009, Radiology.

[97]  Optimal gantry angles and field sizes in kilovoltage cone-beam tomosynthesis for set-up of women with breast cancer undergoing radiotherapy treatment. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[98]  Lubomir M. Hadjiiski,et al.  Artifact Reduction Methods for Truncated Projections in Iterative Breast Tomosynthesis Reconstruction , 2009, Journal of computer assisted tomography.

[99]  Ying Chen,et al.  Impulse response characterization of breast tomosynthesis reconstruction with parallel imaging configurations , 2010, Medical Imaging.

[100]  Guang Yang,et al.  Combined Reconstruction and Registration of Digital Breast Tomosynthesis , 2010, Digital Mammography / IWDM.

[101]  R. Cormack,et al.  Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setupa). , 2010, Medical physics.

[102]  K Bliznakova,et al.  Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry. , 2010, Medical physics.

[103]  Michael Brady,et al.  A Clustering Method for the Extraction of Microcalcifications Using Epipolar Curves in Digital Breast Tomosynthesis , 2010, Digital Mammography / IWDM.

[104]  Ehsan Samei,et al.  Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance. , 2010, Medical physics.

[105]  James G. Nagy,et al.  Numerical Algorithms for Polyenergetic Digital Breast Tomosynthesis Reconstruction , 2010, SIAM J. Imaging Sci..

[106]  Michael Brady,et al.  Microcalcification Detection in Digital Breast Tomosynthesis Using an Epipolar Curve Approach , 2010, Digital Mammography / IWDM.

[107]  Stanislaw Majewski,et al.  Dual-modality breast tomosynthesis. , 2010, Radiology.

[108]  Aldo Badano,et al.  A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms. , 2010, Medical physics.

[109]  Michael Brady,et al.  Classification of clusters of microcalcifications in digital breast tomosynthesis , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[110]  Ann-Katherine Carton,et al.  Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation. , 2010, Medical physics.

[111]  Gang Wu,et al.  Breast Tomosynthesis Reconstruction Using a Grid of Blobs with Projection Matrices , 2010, Digital Mammography / IWDM.

[112]  Andrew D. A. Maidment,et al.  Dual-energy contrast-enhanced digital breast tomosynthesis--a feasibility study. , 2010, The British journal of radiology.

[113]  Lubomir M. Hadjiiski,et al.  Selective-diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis reconstruction. , 2010, Medical physics.

[114]  Gang Wu,et al.  Task-Based Evaluation of Image Quality of Filtered Back Projection for Breast Tomosynthesis , 2010, Digital Mammography / IWDM.

[115]  Serge Muller,et al.  Noise Reduction in Dual-Energy Contrast Enhanced Digital Breast Tomosynthesis Using Regularization , 2010, Digital Mammography / IWDM.

[116]  Michael Brady,et al.  Feature Point Detection for Non-rigid Registration of Digital Breast Tomosynthesis Images , 2010, Digital Mammography / IWDM.

[117]  Ehsan Samei,et al.  The quantitative potential for breast tomosynthesis imaging. , 2010, Medical physics.

[118]  Ann-Katherine Carton,et al.  Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model. , 2010, Medical physics.

[119]  Xinhua Li,et al.  A generic geometric calibration method for tomographic imaging systems with flat-panel detectors--a detailed implementation guide. , 2010, Medical physics.

[120]  Thomas Mertelmeier,et al.  Regularization Parameter Selection in Maximum a Posteriori Iterative Reconstruction for Digital Breast Tomosynthesis , 2010, Digital Mammography / IWDM.

[121]  Ehsan Samei,et al.  Quantitative breast tomosynthesis: from detectability to estimability. , 2010, Medical physics.

[122]  Wei Zhao,et al.  Breast Structural Noise in Digital Breast Tomosynthesis and Its Dependence on Reconstruction Methods , 2010, Digital Mammography / IWDM.

[123]  Berkman Sahiner,et al.  Characterization of masses in digital breast tomosynthesis: comparison of machine learning in projection views and reconstructed slices. , 2010, Medical physics.

[124]  David A. Boas,et al.  Compositional-prior-guided image reconstruction algorithm for multi-modality imaging , 2010, Biomedical optics express.

[125]  Xiangyang Tang,et al.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT-Noise power spectrum NPS(k). , 2011, Medical physics.

[126]  Joseph Y. Lo,et al.  Mutual information-based template matching scheme for detection of breast masses: From mammography to digital breast tomosynthesis , 2011, J. Biomed. Informatics.

[127]  Nico Karssemeijer,et al.  Correlating locations in ipsilateral breast tomosynthesis views using an analytical hemispherical compression model. , 2011, Physics in medicine and biology.

[128]  John M. Boone,et al.  Task-based performance analysis of FBP, SART and ML for digital breast tomosynthesis using signal CNR and Channelised Hotelling Observers , 2011, Medical Image Anal..

[129]  Aili Bloomquist,et al.  Dependence of image quality on geometric factors in breast tomosynthesis. , 2011, Medical physics.

[130]  Jeffrey A. Fessler,et al.  Adaptive diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis (DBT) reconstruction , 2011, Medical Imaging.

[131]  Ehsan Samei,et al.  Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality , 2011, Physics in medicine and biology.

[132]  Christer Ullberg,et al.  Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography , 2011, Acta radiologica.

[133]  U. Bick,et al.  Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging. , 2011, Radiology.

[134]  Sara Gavenonis,et al.  Calcifications in the Breast and Digital Breast Tomosynthesis , 2011, The breast journal.

[135]  Ioannis Sechopoulos,et al.  Automatic tissue classification for high-resolution breast CT images based on bilateral filtering , 2011, Medical Imaging.

[136]  Andrew D. A. Maidment,et al.  Analysis of parenchymal texture with digital breast tomosynthesis: comparison with digital mammography and implications for cancer risk assessment. , 2011, Radiology.

[137]  Xinhua Li,et al.  Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems. , 2010, Medical physics.

[138]  David Gur,et al.  Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. , 2011, AJR. American journal of roentgenology.

[139]  Michael Grass,et al.  A second pass correction method for calcification artifacts in digital breast tomosynthesis , 2011, Medical Imaging.

[140]  Grace J Gang,et al.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance. , 2011, Medical physics.

[141]  Brian W. Pogue,et al.  Semi-automated segmentation and classification of digital breast tomosynthesis reconstructed images , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[142]  Lei Xing,et al.  GPU computing in medical physics: a review. , 2011, Medical physics.

[143]  E. Miller,et al.  Combined optical and X-ray tomosynthesis breast imaging. , 2011, Radiology.

[144]  Howard C. Gifford,et al.  Penalized Maximum Likelihood Reconstruction for Improved Microcalcification Detection in Breast Tomosynthesis , 2011, IEEE Transactions on Medical Imaging.

[145]  D. Bluemke,et al.  3-T dynamic contrast-enhanced MRI of the breast: pharmacokinetic parameters versus conventional kinetic curve analysis. , 2011, AJR. American journal of roentgenology.

[146]  David R Pickens,et al.  Phase-contrast digital tomosynthesis. , 2011, Medical physics.

[147]  Anita Nosratieh,et al.  Anatomical complexity in breast parenchyma and its implications for optimal breast imaging strategies. , 2012, Medical physics.

[148]  I. Sechopoulos,et al.  Cupping artifact correction and automated classification for high-resolution dedicated breast CT images. , 2012, Medical physics.

[149]  Chuan Zhou,et al.  Multiscale regularized reconstruction for enhancing microcalcification in digital breast tomosynthesis , 2012, Medical Imaging.

[150]  Giuseppe Rescinito,et al.  Mammographic density estimation: one-to-one comparison of digital mammography and digital breast tomosynthesis using fully automated software , 2012, European Radiology.

[151]  Dominique Van de Sompel,et al.  Regularising limited view tomography using anatomical reference images and information theoretic similarity metrics , 2012, Medical Image Anal..

[152]  Ann-Katherine Carton,et al.  Impact of image acquisition timing on image quality for dual energy contrast-enhanced breast tomosynthesis , 2012, Medical Imaging.

[153]  David Gur,et al.  Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study. , 2012, Academic radiology.

[154]  Dieter Klatt,et al.  Evaluation of tomosynthesis elastography in a breast-mimicking phantom. , 2012, European journal of radiology.

[155]  Piotr Zygmanski,et al.  Optimal parameters for clinical implementation of breast cancer patient setup using Varian DTS software , 2012, Journal of applied clinical medical physics.

[156]  Ioannis Sechopoulos,et al.  Clinical digital breast tomosynthesis system: dosimetric characterization. , 2012, Radiology.

[157]  Federica Zanca,et al.  Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study. , 2012, Radiology.

[158]  Berkman Sahiner,et al.  Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: a 3D approach. , 2011, Medical physics.