Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers

Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2)  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

[1]  M. Livingstone,et al.  Controlled Ultrasound-Induced Blood-Brain Barrier Disruption Using Passive Acoustic Emissions Monitoring , 2012, PloS one.

[2]  T. Yen,et al.  Submicron-Bubble-Enhanced Focused Ultrasound for Blood–Brain Barrier Disruption and Improved CNS Drug Delivery , 2014, PloS one.

[3]  C. Holland,et al.  Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound. , 2014, The Journal of the Acoustical Society of America.

[4]  Natalia Vykhodtseva,et al.  500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls , 2004, Magnetic resonance in medicine.

[5]  Natalia Vykhodtseva,et al.  Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: safety and efficacy evaluation in rhesus macaques. , 2012, Cancer research.

[6]  K. Hynynen,et al.  Targeted delivery of antibodies through the blood-brain barrier by MRI-guided focused ultrasound. , 2006, Biochemical and biophysical research communications.

[7]  T. Yen,et al.  Quantitative micro-SPECT/CT for detecting focused ultrasound-induced blood-brain barrier opening in the rat. , 2009, Nuclear medicine and biology.

[8]  Lawrence A Crum,et al.  Inertial cavitation dose and hemolysis produced in vitro with or without Optison. , 2003, Ultrasound in medicine & biology.

[9]  Ferenc A. Jolesz,et al.  Local and reversible blood–brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications , 2005, NeuroImage.

[10]  Kullervo Hynynen,et al.  Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain--a primate study. , 2006, European journal of radiology.

[11]  Kullervo Hynynen,et al.  Large improvement of the electrical impedance of imaging and high-intensity focused ultrasound (HIFU) phased arrays using multilayer piezoelectric ceramics coupled in lateral mode , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Mu-Yi Hua,et al.  Novel magnetic/ultrasound focusing system enhances nanoparticle drug delivery for glioma treatment. , 2010, Neuro-oncology.

[13]  E. Konofagou,et al.  Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening , 2015, Physics in medicine and biology.

[14]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[15]  Chung-Chih Lin,et al.  Design and Experimental Evaluation of a 256-Channel Dual-Frequency Ultrasound Phased-Array System for Transcranial Blood–Brain Barrier Opening and Brain Drug Delivery , 2014, IEEE Transactions on Biomedical Engineering.

[16]  Jiun-Jie Wang,et al.  Magnetic-resonance imaging for kinetic analysis of permeability changes during focused ultrasound-induced blood-brain barrier opening and brain drug delivery. , 2014, Journal of controlled release : official journal of the Controlled Release Society.

[17]  K. Hynynen,et al.  Targeted disruption of the blood–brain barrier with focused ultrasound: association with cavitation activity , 2006, Physics in medicine and biology.

[18]  Natalia Vykhodtseva,et al.  Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI‐guided focused ultrasound , 2007, International journal of cancer.

[19]  K. Hynynen,et al.  Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. , 2001, Radiology.

[20]  Feng-Yi Yang,et al.  Micro-SPECT/CT–Based Pharmacokinetic Analysis of 99mTc-Diethylenetriaminepentaacetic Acid in Rats with Blood–Brain Barrier Disruption Induced by Focused Ultrasound , 2011, The Journal of Nuclear Medicine.

[21]  F A Jolesz,et al.  Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. , 1998, Ultrasound in medicine & biology.

[22]  Kullervo Hynynen,et al.  A numerical study of transcranial focused ultrasound beam propagation at low frequency , 2005, Physics in medicine and biology.

[23]  Natalia Vykhodtseva,et al.  Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery. , 2006, Journal of neurosurgery.

[24]  K. Hynynen,et al.  Transcranial Magnetic Resonance Imaging– Guided Focused Ultrasound Surgery of Brain Tumors: Initial Findings in 3 Patients , 2010, Neurosurgery.

[25]  Elisa E. Konofagou,et al.  Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  Yao-Sheng Tung,et al.  In vivo transcranial cavitation threshold detection during ultrasound-induced blood–brain barrier opening in mice , 2010, Physics in medicine and biology.

[27]  Mu-Yi Hua,et al.  Magnetic resonance monitoring of focused ultrasound/magnetic nanoparticle targeting delivery of therapeutic agents to the brain , 2010, Proceedings of the National Academy of Sciences.

[28]  T. Yen,et al.  Contrast-Enhanced Ultrasound Imaging for the Detection of Focused Ultrasound-Induced Blood-Brain Barrier Opening , 2014, Theranostics.

[29]  Alexey S. Peshkovsky,et al.  Acoustic cavitation theory and equipment design principles for industrial applications of high-intensity ultrasound , 2010 .

[30]  Mickael Tanter,et al.  Attenuation, scattering, and absorption of ultrasound in the skull bone. , 2011, Medical physics.

[31]  K Hynynen,et al.  Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo. , 1995, Ultrasound in medicine & biology.

[32]  Nathan McDannold,et al.  Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies. , 2013, Medical physics.

[33]  Kullervo Hynynen,et al.  Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study , 2013, Physics in medicine and biology.

[34]  Kullervo Hynynen,et al.  Blood-brain barrier: real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller. , 2012, Radiology.

[35]  V. Ferrera,et al.  Noninvasive, Transient and Selective Blood-Brain Barrier Opening in Non-Human Primates In Vivo , 2011, PloS one.

[36]  Meaghan A. O'Reilly,et al.  A PVDF Receiver for Ultrasound Monitoring of Transcranial Focused Ultrasound Therapy , 2010, IEEE Transactions on Biomedical Engineering.

[37]  Yau-Yau Wai,et al.  Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging. , 2008, Ultrasound in medicine & biology.

[38]  Manabu Kinoshita,et al.  Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[39]  Fabrice Marquet,et al.  Real-Time, Transcranial Monitoring of Safe Blood-Brain Barrier Opening in Non-Human Primates , 2012, 2012 IEEE International Ultrasonics Symposium.

[40]  J. Barger,et al.  Acoustical properties of the human skull. , 1978, The Journal of the Acoustical Society of America.

[41]  Matthew E. Downs,et al.  Transcranial cavitation detection in primates during blood-brain barrier opening-a performance assessment study , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[42]  Mu-Yi Hua,et al.  Blood-brain barrier disruption with focused ultrasound enhances delivery of chemotherapeutic drugs for glioblastoma treatment. , 2010, Radiology.

[43]  V. Ferrera,et al.  Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates. , 2011, Applied physics letters.