Amorphous selenium direct detection CMOS digital x-ray imager with 25 micron pixel pitch

We have developed a high resolution amorphous selenium (a-Se) direct detection imager using a large-area compatible back-end fabrication process on top of a CMOS active pixel sensor having 25 micron pixel pitch. Integration of a-Se with CMOS technology requires overcoming CMOS/a-Se interfacial strain, which initiates nucleation of crystalline selenium and results in high detector dark currents. A CMOS-compatible polyimide buffer layer was used to planarize the backplane and provide a low stress and thermally stable surface for a-Se. The buffer layer inhibits crystallization and provides detector stability that is not only a performance factor but also critical for favorable long term cost-benefit considerations in the application of CMOS digital x-ray imagers in medical practice. The detector structure is comprised of a polyimide (PI) buffer layer, the a-Se layer, and a gold (Au) top electrode. The PI layer is applied by spin-coating and is patterned using dry etching to open the backplane bond pads for wire bonding. Thermal evaporation is used to deposit the a-Se and Au layers, and the detector is operated in hole collection mode (i.e. a positive bias on the Au top electrode). High resolution a-Se diagnostic systems typically use 70 to 100 μm pixel pitch and have a pre-sampling modulation transfer function (MTF) that is significantly limited by the pixel aperture. Our results confirm that, for a densely integrated 25 μm pixel pitch CMOS array, the MTF approaches the fundamental material limit, i.e. where the MTF begins to be limited by the a-Se material properties and not the pixel aperture. Preliminary images demonstrating high spatial resolution have been obtained from a frst prototype imager.

[1]  J. A. Rowlands,et al.  The effect of the substrate on transient photodarkening in stabilized amorphous selenium , 2012 .

[2]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: inherent spatial resolution. , 1995, Medical physics.

[3]  Safa Kasap,et al.  Selenium coated CMOS passive pixel array for medical imaging , 2011, Medical Imaging.

[4]  J. A. Rowlands,et al.  Frustration of photocrystallization in amorphous selenium films and film-polymer structures near the glass transition , 2013 .

[5]  Michael P. Andre,et al.  Integrated CMOS-selenium x-ray detector for digital mammography , 1998, Medical Imaging.

[6]  Karim S. Karim,et al.  Investigation of Hole-Blocking Contacts for High-Conversion-Gain Amorphous Selenium Detectors for X-Ray Imaging , 2012, IEEE Transactions on Electron Devices.

[7]  I A Cunningham,et al.  Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors. , 2006, Medical physics.

[8]  Arokia Nathan,et al.  Amorphous silicon active pixel sensor readout circuit for digital imaging , 2003 .

[9]  Gyuseong Cho,et al.  An X-ray imaging detector based on pixel structured scintillator , 2007 .

[10]  G. Cho,et al.  Improvement of the sensitivity and spatial resolution of pixelated CsI:Tl scintillator with reflective coating , 2009 .

[11]  I A Cunningham,et al.  Fundamental x-ray interaction limits in diagnostic imaging detectors: spatial resolution. , 2008, Medical physics.

[12]  Wei Zhang,et al.  A high spatial resolution CsI:Tl scintillation film based on net-like substrate , 2010, International Conference on Thin Film Physics and Applications.

[13]  Karim S. Karim,et al.  Enhanced Detection Efficiency of Direct Conversion X-ray Detector Using Polyimide as Hole-Blocking Layer , 2013, Scientific Reports.

[14]  Larry Partain,et al.  50 μm pixel size a-Se mammography imager with high DQE and increased temperature resistance , 2010, Medical Imaging.

[15]  Mu Gu,et al.  Performance of columnar CsI(Tl) scintillation films prepared on special pre-deposited layers , 2013 .