Vibration control in wind turbines for performance enhancement: A comparative study

The need for a more affordable, reliable, clean and secure energy has led to explorations in non-traditional sources, particularly renewable energies. Wind is one of the cleanest energy sources that plays a significant role in augmenting sustainability. Wind turbines, as energy convertors, are usually tall and slender structures, and depending on their location (inland or offshore), they can be subject to high wind and/or strong wave loadings. These loads can cause severe vibrations with detrimental effects on energy production, structural lifecycle and initial cost. A dissipativity analysis study was carried out to know whether wind turbine towers require damping enhancement or rigidity modifications for vibration suppression. The results suggest that wind turbines are lightly damped structures and damping enhancement is a potential solution for vibration lessening. Accordingly, the paper investigates different damping enhancement techniques for vibration mitigation. The efficacy of tuned mass damper (TMD), tuned liquid column damper (TLCD), tuned sloshing damper (TSD), and viscous damper (VD) to reduce vibrations is investigated. A comparison among these devices, in terms of robustness and effectiveness, is conducted. The VD can reduce both displacement and acceleration responses of the tower, better than other types of dampers, for the same control effort, followed by TMD, TSD, and finally TLCD. Nevertheless, the use of VDs raises concerns about where they should be located in the structure, and their application may require additional design considerations.

[1]  Jie Yang,et al.  Pull-in instability of electrically actuated poly-SiGe graded micro-beams , 2013 .

[2]  M. Pirner,et al.  Liquid damper for suppressing horizontal and vertical motions—parametric study , 2007 .

[3]  Ging Long Lin,et al.  Vibration control of seismic structures using semi-active friction multiple tuned mass dampers , 2010 .

[4]  S. Shokat,et al.  電界応答性キトサン-ポリ(N,N-ジメチルアクリルアミド)セミIPNゲル膜およびそれらの誘電,熱および膨潤キャラクタリゼーション , 2013 .

[5]  Subrata Chakraborty,et al.  Reliability based optimum design of Tuned Mass Damper in seismic vibration control of structures with bounded uncertain parameters , 2011 .

[6]  Michael Willford,et al.  The damped outrigger concept for tall buildings , 2007 .

[7]  Kyung-Won Min,et al.  Experimental verification on nonlinear dynamic characteristic of a tuned liquid column damper subjected to various excitation amplitudes , 2012 .

[8]  Jong-Cheng Wu,et al.  Wind tunnel verification of actively controlled high-rise building in along-wind motion , 2002 .

[9]  Mario A. Rotea,et al.  Structural control of floating wind turbines , 2011 .

[10]  Hua Jun Li,et al.  H2 active vibration control for offshore platform subjected to wave loading , 2003 .

[11]  J. Kaimal,et al.  Spectral Characteristics of Surface-Layer Turbulence , 1972 .

[12]  Hamid Reza Karimi,et al.  Modelling and optimization of a passive structural control design for a spar-type floating wind turbine , 2014 .

[13]  Leonardo Dueñas-Osorio,et al.  Unavailability of wind turbines due to wind-induced accelerations , 2008 .

[14]  Young-Kyu Ju,et al.  Wind‐induced vibration control of tall buildings using hybrid buckling‐restrained braces , 2014 .

[15]  Leonardo Dueñas-Osorio,et al.  Improved reliability of wind turbine towers with tuned liquid column dampers (TLCDs) , 2014 .

[16]  Frank Schilder,et al.  Exploring the performance of a nonlinear tuned mass damper , 2009 .

[17]  Biswajit Basu,et al.  Tuned liquid column dampers in offshore wind turbines for structural control , 2009 .

[18]  Maria Q. Feng,et al.  Vibration Control of Tall Buildings Using Mega Subconfiguration , 1995 .

[19]  Subrata Chakraborty,et al.  Optimum design of tuned liquid column dampers under stochastic earthquake load considering uncertain bounded system parameters , 2010 .

[20]  Aly Mousaad Aly,et al.  Proposed robust tuned mass damper for response mitigation in buildings exposed to multidirectional wind , 2014 .

[21]  Seung-Yong Ok,et al.  Optimal design of hybrid control system for new and old neighboring buildings , 2015 .

[22]  Walter Musial,et al.  Trends in the Design, Manufacture and Evaluation of Wind Turbine Blades , 2003 .

[23]  Torgeir Moan,et al.  A simplified method for coupled analysis of floating offshore wind turbines , 2012 .

[24]  Matthew A. Lackner,et al.  The impact of passive tuned mass dampers and wind–wave misalignment on offshore wind turbine loads , 2014 .

[25]  Kyung-Won Min,et al.  A design procedure of two-way liquid dampers for attenuation of wind-induced responses of tall buildings , 2014 .

[26]  Edward Rosen Copernicus and Al-Bitruji , 1960 .

[27]  Biswajit Basu,et al.  Passive control of floating offshore wind turbine nacelle and spar vibrations by multiple tuned mass dampers , 2015 .

[28]  Chih-Chen Chang,et al.  Mass dampers and their optimal designs for building vibration control , 1999 .

[29]  F. Weber,et al.  Semi-active vibration absorber based on real-time controlled MR damper , 2014 .

[30]  Biswajit Basu,et al.  Passive control of wind turbine vibrations including blade/tower interaction and rotationally sampled turbulence , 2008 .

[31]  Kyung-Won Min,et al.  Design and test of tuned liquid mass dampers for attenuation of the wind responses of a full scale building , 2014 .

[32]  Alberto Zasso,et al.  On the dynamics of a very slender building under winds: response reduction using MR dampers with lever mechanism , 2011 .

[33]  Limin Sun,et al.  Active mass damper control for cable stayed bridge under construction: an experimental study , 2011 .

[34]  Kum-Gil Sung,et al.  Optimal control of structural vibrations using a mixed-mode magnetorheological fluid mount , 2008 .

[35]  Ervin Bossanyi,et al.  Individual Blade Pitch Control for Load Reduction , 2003 .

[36]  Felix Weber,et al.  Frequency and damping adaptation of a TMD with controlled MR damper , 2012 .

[37]  Dietrich Lohrmann,et al.  Von der östlichen zur westlichen Windmühle , 1995 .

[38]  Matthew A. Lackner,et al.  DEVELOPMENT OF A FREE VORTEX WAKE METHOD CODE FOR OFFSHORE FLOATING WIND TURBINES , 2012 .

[39]  Knut O. Ronold,et al.  Reliability-based design of wind-turbine rotor blades against failure in ultimate loading , 2000 .

[40]  Aly Mousaad Aly,et al.  Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper , 2014 .

[41]  Wl L. Qu,et al.  Unified dynamic absorber design formulas for wind‐induced vibration control of tall buildings , 1998 .

[42]  Cheng-Wu Chen,et al.  Active control for a benchmark building under wind excitations , 2003 .