Heat transfer and friction characteristics of rotor-assembled strand heat exchanger studied by uniform design experiment

The uniform distribution and experimental design is employed to study the thermo-hydraulic characteristics of a heat exchanger, which consists of the rotor-assembled strands mounted in circular smooth tubes. The uniform distribution and experimental design parameters include multiple rotor parameters such as rotor diameters, rotor lead, and height of blade, with the aim of studying their influence on the PEC, that is, ( ( Nu z / Nu g ) / ( f g / f z ) 1 / 3 ), which stands for the heat transfer and friction characteristics. The best matching schemes of rotor-assembled strand, which significantly improves PEC to 2.01, are given by the regression analysis of uniform distribution and experimental design table. The single-factor experiments are performed to compare a tube installed with different kinds of rotor-assembled strands with a smooth tube without any strands when the Reynolds number changes between 20,000 and 60,000. The experimental result is in good agreement with the result obtained by the regression analysis of uniform distribution and experimental design. It is shown that the rotor diameters play important role in the heat transfer, and the optimal PEC value is obtained under the case that the rotor diameter is 21 mm. The rotor lead also contributes to the improvement of heat transfer and its optimal value is 700 mm in this study. The Nusselt number, friction factor and PEC increase with the increase in blade height. It shows that the uniform distribution and experimental design is an efficient method to find out the optimal parameters.

[1]  Zhang Zhen,et al.  Heat transfer and friction characteristics of turbulent flow through plain tube inserted with rotor-assembled strands , 2012 .

[2]  Yong Zhang,et al.  Uniform Design: Theory and Application , 2000, Technometrics.

[3]  Abdulmajeed A. Mohamad,et al.  Heat transfer enhancements in heat exchangers fitted with porous media Part I: constant wall temperature , 2003 .

[4]  Weimin Yang,et al.  Performance assessment in a tube with rotor-assembled strands mixed by spiral slot rotor and low flow resistance rotor , 2013 .

[5]  Qingyu Lin STUDY ON THE HEAT TRANSFER ENHANCEMENT BY THE HYDRAULIC TURBINE IN A TUBE , 2004 .

[6]  Pongjet Promvonge,et al.  Turbulent convection in round tube equipped with propeller type swirl generators , 2009 .

[7]  Hassan Pahlavanzadeh,et al.  Experimental study of thermo-hydraulic and fouling performance of enhanced heat exchangers ☆ , 2007 .

[8]  Kai-Tai Fang Uniform Experimental Design , 2011, International Encyclopedia of Statistical Science.

[9]  Heat transfer enhancement in the tube fitted with Left–Right helical blade rotors , 2013 .

[10]  Heat transfer characteristics in micro-fin tube equipped with double twisted tapes: Effect of twisted tape and micro-fin tube arrangements , 2013 .

[11]  Performance assessment in a tube with rotor-assembled strands mixed by spiral ladder rotor and low flow resistance rotor , 2015 .

[12]  Paisarn Naphon,et al.  Effect of coil-wire insert on heat transfer enhancement and pressure drop of the horizontal concentric tubes , 2006 .