Human activity monitoring using gas sensor arrays

A chemical detection system made of a gas sensor array and algorithms intended to monitor human activity was tested in a NASA spacecraft cabin simulator. Such a chemical-based monitoring system, if extended to home settings, would allow the autonomous detection of emergency situations, thereby postponing the moving of elderly people to assisted living facilities and improving their quality of life. Moreover, in contrast to other monitoring systems based on wearable sensors or video cameras, a monitoring system based on measuring changes in air composition induced by human activities would be non-invasive and would not raise privacy concerns when installed in homes. The third generation of the JPL sensor array was adapted in a small, compact and portable system and deployed in a spacecraft-like room for four weeks while volunteers were performing daily routines. The system was able to predict the total number of people and the level of activity performed in the room, while detecting unexpectedly high concentrations of volatiles.

[1]  M. Ryan,et al.  Polymer—Carbon Black Composite Sensors in an Electronic Nose for Air-Quality Monitoring , 2004, MRS bulletin.

[2]  Corinna Cortes,et al.  Support-Vector Networks , 1995, Machine Learning.

[3]  M. Ogawa,et al.  Monitoring daily activities and behaviors at home by using brief sensors , 2000, 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451).

[4]  Alexander Vergara,et al.  On the calibration of sensor arrays for pattern recognition using the minimal number of experiments , 2014 .

[5]  J. Huber,et al.  Detection of bad indoor environment with a miniaturized gas sensor system , 2013, Microtechnologies for the New Millennium.

[6]  Margaret A. K. Ryan,et al.  Ground Validation of the Third Generation JPL Electronic Nose , 2008 .

[7]  Bernhard Schölkopf,et al.  A tutorial on support vector regression , 2004, Stat. Comput..

[8]  Paolo Bonato,et al.  Wearable Sensors and Systems , 2010, IEEE Engineering in Medicine and Biology Magazine.

[9]  Jay L. Perry,et al.  Operation of a Third Generation JPL Electronic Nose in the Regenerative ECLSS Module Simulator at MSFC , 2010 .

[10]  Shankar Vembu,et al.  Chemical gas sensor drift compensation using classifier ensembles , 2012 .

[11]  Akira Okada,et al.  Proposition of a survey device with odor sensors for an elderly person , 2003 .

[12]  Pere Caminal,et al.  Drift Compensation of Gas Sensor Array Data by Common Principal Component Analysis , 2010 .

[13]  Hanying Zhou,et al.  Nonlinear Least-Squares Based Method for Identifying and Quantifying Single and Mixed Contaminants in Air with an Electronic Nose , 2005, Sensors (Basel, Switzerland).

[14]  Alexandre Perera,et al.  Drift compensation of gas sensor array data by Orthogonal Signal Correction , 2010 .

[15]  Margaret A. K. Ryan,et al.  Conductometric Sensors for Detection of Elemental Mercury Vapor , 2008 .

[16]  Xi Chen,et al.  Activity Analysis, Summarization, and Visualization for Indoor Human Activity Monitoring , 2008, IEEE Transactions on Circuits and Systems for Video Technology.

[17]  Fredrik Winquist,et al.  Drift counteraction in odour recognition applications: lifelong calibration method , 1997 .

[18]  Robert X. Gao,et al.  Wireless Design of a Multisensor System for Physical Activity Monitoring , 2012, IEEE Transactions on Biomedical Engineering.

[19]  M. A. Ryan The process of developing an instrument: the JPL electronic nose , 2012, Defense, Security, and Sensing.

[20]  A. Lilienthal,et al.  Creating true gas concentration maps in presence of multiple heterogeneous gas sources , 2012, 2012 IEEE Sensors.

[21]  Araceli Sanchis,et al.  Activity Recognition Using Hybrid Generative/Discriminative Models on Home Environments Using Binary Sensors , 2013, Sensors.

[22]  Takashi Oyabu,et al.  Odor sensing characteristics of a lavatory in a general domicile , 2001 .

[23]  J. Blanco,et al.  Calibration of MOX gas sensors in open sampling systems based on Gaussian Processes , 2012, 2012 IEEE Sensors.

[24]  Takamichi Nakamoto,et al.  Study of autonomous mobile sensing system for localization of odor source using gas sensors and anemometric sensors , 1994 .

[25]  Manuele Bernabei,et al.  Design of a very large chemical sensor system for mimicking biological olfaction , 2010 .

[26]  Aleksandar Milenkovic,et al.  Wireless sensor networks for personal health monitoring: Issues and an implementation , 2006, Comput. Commun..

[27]  Eduard Llobet,et al.  Reducing power consumption via a discontinuous operation of temperature-modulated micro-hotplate gas sensors: Application to the logistics chain of fruit☆ , 2008 .

[28]  Ramón Huerta,et al.  A unified framework for Volatile Organic Compound classification and regression , 2010, The 2010 International Joint Conference on Neural Networks (IJCNN).

[29]  C. Natale,et al.  Sensor-array calibration time reduction by dynamic modelling , 1995 .

[30]  R. Huerta,et al.  Temperature optimization of metal oxide sensor arrays using Mutual Information , 2013 .

[31]  Nikolai F. Rulkov,et al.  On the performance of gas sensor arrays in open sampling systems using Inhibitory Support Vector Machines , 2013 .

[32]  Javier Reina-Tosina,et al.  SoM: A Smart Sensor for Human Activity Monitoring and Assisted Healthy Ageing , 2012, IEEE Transactions on Biomedical Engineering.

[33]  Ling Bao,et al.  Activity Recognition from User-Annotated Acceleration Data , 2004, Pervasive.

[34]  April D. Jewell,et al.  Correlating polymer-carbon composite sensor response with molecular descriptors , 2006 .

[35]  S. Sathiya Keerthi,et al.  Improvements to the SMO algorithm for SVM regression , 2000, IEEE Trans. Neural Networks Learn. Syst..

[36]  Alexander Vergara,et al.  Algorithmic mitigation of sensor failure: is sensor replacement really necessary? , 2013 .

[37]  Tanvi Banerjee,et al.  Testing an in-home gait assessment tool for older adults , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  K. Aminian,et al.  Physical activity monitoring based on accelerometry: validation and comparison with video observation , 1999, Medical & Biological Engineering & Computing.

[39]  R. Beccherelli,et al.  Large-Scale Chemical Sensor Array Testing Biological Olfaction Concepts , 2012, IEEE Sensors Journal.

[40]  Kamiar Aminian,et al.  Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly , 2003, IEEE Transactions on Biomedical Engineering.

[41]  Marjorie Skubic,et al.  Evaluation of an inexpensive depth camera for in-home gait assessment , 2011, J. Ambient Intell. Smart Environ..

[42]  M A Ryan,et al.  Molecular modeling of polymer composite-analyte interactions in electronic nose sensors. , 2003, Sensors and actuators. B, Chemical.

[43]  Misha Pavel,et al.  Unobtrusive and Ubiquitous In-Home Monitoring: A Methodology for Continuous Assessment of Gait Velocity in Elders , 2010, IEEE Transactions on Biomedical Engineering.