The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning

The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to combat these problems. This study provides a qualitative and quantitative analysis of the “Smart MAR” software (General Electric Healthcare, Chicago, IL, USA), determining its usefulness in a clinical setting. A detailed analysis was conducted using both patient and phantom data, noting any improvements in HU values and dosimetry with the GE-MAR enabled. This study indicates qualitative improvements in severity of the streak artefacts produced by metals, allowing for easier patient contouring. Furthermore, the GE-MAR managed to recover previously lost anatomical information. Additionally, phantom data showed an improvement in HU value with GE-MAR correction, producing more accurate point dose calculations in the treatment planning system. Overall, the GE-MAR is a useful tool and is suitable for clinical environments.

[1]  Yong-Min Huh,et al.  Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  Sasa Mutic,et al.  Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy. , 2012, Medical physics.

[3]  Johan Nuyts,et al.  An experimental survey of metal artefact reduction in computed tomography. , 2013, Journal of X-ray science and technology.

[4]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[5]  Sebastian Bickelhaupt,et al.  Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions. , 2013, Radiology.

[6]  Paul Brown,et al.  Effect of spine hardware on small spinal stereotactic radiosurgery dosimetry , 2013, Physics in medicine and biology.

[7]  K Harada,et al.  Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR). , 2014, Clinical radiology.

[8]  Steve B. Jiang,et al.  A hybrid metal artifact reduction algorithm for x-ray CT. , 2013, Medical physics.

[9]  Dimitre Hristov,et al.  Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy. , 2015, Medical physics.

[10]  D. Hristov,et al.  Evaluation of a metal artifact reduction technique in tonsillar cancer delineation. , 2012, Practical radiation oncology.

[11]  Anders Ahnesjö,et al.  Evaluation of a metal artifact reduction algorithm in CT studies used for proton radiotherapy treatment planning , 2014, Journal of applied clinical medical physics.

[12]  W. S. Rasband,et al.  ImageJ: Image processing and analysis in Java , 2012 .

[13]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[14]  Mehran Yazdi,et al.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. , 2005, International journal of radiation oncology, biology, physics.

[15]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[16]  F. Boas,et al.  CT artifacts: Causes and reduction techniques , 2012 .

[17]  Francesco C Stingo,et al.  An evaluation of three commercially available metal artifact reduction methods for CT imaging , 2015, Physics in medicine and biology.

[18]  Rainer Raupach,et al.  Frequency split metal artifact reduction (FSMAR) in computed tomography. , 2012, Medical physics.

[19]  M. Osanai,et al.  Photon starvation artifacts of X-ray CT: their true cause and a solution , 2012, Radiological Physics and Technology.

[20]  John R Yarnold,et al.  Clinical impact of IMPORT HIGH trial (CRUK/06/003) on breast radiotherapy practices in the United Kingdom. , 2015, The British journal of radiology.

[21]  P. Thunberg,et al.  Metal artefact reduction in CT imaging of hip prostheses—an evaluation of commercial techniques provided by four vendors. , 2015, The British journal of radiology.