Experimental mechanical characterization of abdominal organs: liver, kidney & spleen.
暂无分享,去创建一个
Luc Soler | Jacques Marescaux | Sagar Umale | Caroline Deck | Nicolas Bourdet | Remy Willinger | J. Marescaux | L. Soler | Sagar Umale | R. Willinger | C. Deck | P. Dhumane | N. Bourdet | Parag Dhumane
[1] J. Kovanda,et al. Morphology and some biomechanical properties of human liver and spleen , 2002, Surgical and Radiologic Anatomy.
[2] L. Soler,et al. In vivo liver tissue mechanical properties by Transient Elastography: comparison with Dynamic Mechanical Analysis. , 2011, Biorheology.
[3] Dieter Klatt,et al. In Vivo Determination of Hepatic Stiffness Using Steady-State Free Precession Magnetic Resonance Elastography , 2006, Investigative radiology.
[4] P Vezin,et al. A strain-hardening bi-power law for the nonlinear behaviour of biological soft tissues. , 2010, Journal of biomechanics.
[5] K Miller,et al. How to test very soft biological tissues in extension? , 2001, Journal of biomechanics.
[6] Denis Laurendeau,et al. Modelling liver tissue properties using a non-linear visco-elastic model for surgery simulation , 2005, Medical Image Anal..
[7] Edoardo Mazza,et al. Dynamic measurement of soft tissue viscoelastic properties with a torsional resonator device , 2005, Medical Image Anal..
[8] F. G. Evans,et al. Strength of biological materials , 1970 .
[9] K. Chinzei,et al. Mechanical properties of brain tissue in tension. , 2002, Journal of biomechanics.
[10] Suvranu De,et al. An efficient soft tissue characterization algorithm from in vivo indentation experiments for medical simulation , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.
[11] Stephen W. Rouhana,et al. PATTERNS OF ABDOMINAL INJURY IN FRONTAL AUTOMOTIVE CRASHES , 1998 .
[12] Esra Roan,et al. The nonlinear material properties of liver tissue determined from no-slip uniaxial compression experiments. , 2007, Journal of biomechanical engineering.
[13] K. T. Ramesh,et al. Mechanical properties of soft human tissues under dynamic loading. , 2007, Journal of biomechanics.
[14] A. Kemper,et al. Biomechanical response of human liver in tensile loading. , 2010, Annals of advances in automotive medicine. Association for the Advancement of Automotive Medicine. Annual Scientific Conference.
[15] R. Parks,et al. Eleven Years of Liver Trauma: The Scottish Experience , 2005, World Journal of Surgery.
[16] S. Nicolle,et al. Shear mechanical properties of the spleen: experiment and analytical modelling. , 2012, Journal of the mechanical behavior of biomedical materials.
[17] Ichiro Sakuma,et al. In vitro Measurement of Mechanical Properties of Liver Tissue under Compression and Elongation Using a New Test Piece Holding Method with Surgical Glue , 2003, IS4TH.
[18] Jess Gerrit Snedeker,et al. Mechanical Characterization of the Liver Capsule and Parenchyma , 2006, ISBMS.
[19] M. Ziol,et al. Diagnosis of Hepatic Fibrosis and Cirrhosis by Transient Elastography in HIV/Hepatitis C Virus-Coinfected Patients , 2006, Journal of acquired immune deficiency syndromes.
[20] P Flüeler,et al. Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma. , 1999, Journal of biomechanics.
[21] Dieter Klatt,et al. Wide-range dynamic magnetic resonance elastography. , 2011, Journal of biomechanics.
[22] Wen-Chun Yeh,et al. Elastic modulus measurements of human liver and correlation with pathology. , 2002, Ultrasound in medicine & biology.
[23] J. Desai,et al. Constitutive Modeling of Liver Tissue: Experiment and Theory , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.
[24] Christopher W. Macosko,et al. Rheology: Principles, Measurements, and Applications , 1994 .
[25] V. de Lédinghen,et al. Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study , 2005, Gut.
[26] Alessandro Nava,et al. In vivo mechanical characterization of human liver , 2008, Medical Image Anal..
[27] R L Ehman,et al. Tissue characterization using magnetic resonance elastography: preliminary results. , 2000, Physics in medicine and biology.
[28] Jun Okamoto,et al. Measurement of In-vivo Local Shear Modulus by Combining Multiple Phase Offsets MR Elastography , 2001, MedInfo.
[29] M. Coret,et al. Characterization of the nonlinear behaviour and the failure of human liver capsule through inflation tests. , 2011, Journal of the mechanical behavior of biomedical materials.
[30] Blake Hannaford,et al. Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. , 2008, Journal of biomechanical engineering.
[31] Laurent Castera,et al. Non-invasive evaluation of liver fibrosis using transient elastography. , 2008, Journal of hepatology.
[32] K Miller,et al. Constitutive modelling of abdominal organs. , 2000, Journal of biomechanics.
[33] Lynne E. Bilston,et al. Viscoelastic properties of pig kidney in shear, experimental results and modelling , 2002 .
[34] M. Coret,et al. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure. , 2010, Journal of biomechanics.
[35] Michael Bajka,et al. The mechanical response of human liver and its relation to histology: An in vivo study , 2007, Medical Image Anal..
[36] Christos Christidis,et al. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C , 2005, Hepatology.
[37] King H. Yang,et al. Mechanical characterization of porcine abdominal organs. , 2002, Stapp car crash journal.
[38] Jung Kim,et al. Measurement and characterization of soft tissue behavior with surface deformation and force response under large deformations , 2010, Medical Image Anal..
[39] Kennerly Digges,et al. Injury Patterns in Near-Side Collisions , 2000 .
[40] M. Ottensmeyer. Minimally invasive instrument for in vivo measurement of solid organ mechanical impedance , 2001 .
[41] Hervé Delingette,et al. Fast porous visco-hyperelastic soft tissue model for surgery simulation: application to liver surgery. , 2010, Progress in biophysics and molecular biology.
[42] Joel D Stitzel,et al. Biomechanical response of human spleen in tensile loading. , 2012, Journal of biomechanics.
[43] K. Chinzei,et al. Constitutive modelling of brain tissue: experiment and theory. , 1997, Journal of biomechanics.
[44] M. Ziol,et al. Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. , 2003, Ultrasound in medicine & biology.
[45] Luc Soler,et al. Experimental in vitro mechanical characterization of porcine Glisson's capsule and hepatic veins. , 2011, Journal of biomechanics.
[46] Dieter Klatt,et al. Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography. , 2010, Biorheology.
[47] J. Melvin,et al. Accidental Injury: Biomechanics and Prevention , 1993 .
[48] J G Snedeker,et al. Strain-rate dependent material properties of the porcine and human kidney capsule. , 2005, Journal of biomechanics.
[49] S. Nicolle,et al. Dehydration effect on the mechanical behaviour of biological soft tissues: observations on kidney tissues. , 2010, Journal of the mechanical behavior of biomedical materials.
[50] Ichiro Sakuma,et al. Transversely isotropic properties of porcine liver tissue: experiments and constitutive modelling , 2006, Medical & Biological Engineering & Computing.
[51] Anne-Claire Vergnaud,et al. Liver stiffness values in apparently healthy subjects: influence of gender and metabolic syndrome. , 2008, Journal of hepatology.
[52] D C Viano,et al. Biomechanics of liver injury by steering wheel loading. , 1987, The Journal of trauma.
[53] Ioan Sporea,et al. Comparison of the liver stiffness measurement by transient elastography with the liver biopsy. , 2008, World journal of gastroenterology.
[54] R. Lim,et al. Morbidity and mortality in hepatic trauma. A 5 year study. , 1982, American journal of surgery.
[55] Alfred Cuschieri,et al. Measurements and modelling of the compliance of human and porcine organs , 2001, Medical Image Anal..
[56] C. P. Thor,et al. Multi-scale biomechanical characterization of human liver and spleen , 2011 .
[57] W. O’Brien,et al. Young's modulus measurements of soft tissues with application to elasticity imaging , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.