Regional phase correction of inversion‐recovery MR images

Many MR imaging systems are limited in their ability to successfully display inversion‐recovery images. The reason is that part of the contrast is encoded as phase differences between pixels, whereas in the more commonly used spin‐echo pulse sequence all the information is contained in the pixel magnitude. Inversion‐recovery images are often displayed in magnitude form, resulting in loss of potentially useful phase information contained in the data. Before this phase information can be used, phase errors which result from scanner imperfections must be removed. While most of the necessary correction can be accomplished using data obtained by scanning a uniform phantom, this approach has several disadvantages. An alternative method by which phase errors can be readily removed without phantom data is described. This method has been applied to images of the head, knee, and liver with good results. It is concluded that this technique is useful for producing phase corrected inversion‐recovery MR images © 1990 Academic Press, Inc.

[1]  G M Bydder,et al.  MR Imaging: Clinical Use of the Inversion Recovery Sequence , 1985, Journal of computer assisted tomography.

[2]  P. V. van Dijk,et al.  Restoration of Signal Polarity in a Set of Inversion Recovery NMR Images , 1984, IEEE Transactions on Medical Imaging.

[3]  P. R. Moran,et al.  Tissue contrast enhancement: image reconstruction algorithm and selection of TI in inversion recovery MRI. , 1986, Magnetic resonance imaging.

[4]  G. Bydder,et al.  Apparent changes of appearance of inversion‐recovery images , 1985, Magnetic resonance in medicine.

[5]  R T Droege,et al.  Boundary artifact in inversion‐recovery images , 1986, Magnetic resonance in medicine.

[6]  W. Heindel,et al.  Nuclear Magnetic Resonance (NMR) Tomography of the Central Nervous System: Comparison of Two Imaging Sequences , 1983, Journal of computer assisted tomography.

[7]  Z. Cho,et al.  Real‐value representation in inversion‐recovery NMR imaging by use of a phase‐correction method , 1986, Magnetic resonance in medicine.

[8]  M. Kulkarni,et al.  5-T MR imaging of pituitary microadenomas : , 2013 .

[9]  D W Kormos,et al.  Separation of true fat and water images by correcting magnetic field inhomogeneity in situ. , 1986, Radiology.

[10]  J. Wittenberg,et al.  Hepatic metastases: randomized, controlled comparison of detection with MR imaging and CT. , 1987, Radiology.

[11]  E. Laws,et al.  Imaging of cranial chordomas. , 1987, Mayo Clinic proceedings.

[12]  A M Aisen,et al.  Chemical shift-based true water and fat images: regional phase correction of modified spin-echo MR images. , 1987, Radiology.

[13]  Sabrina S Wilson Radiology , 1938, Glasgow Medical Journal.

[14]  R. Duchesneau,et al.  Benign and malignant breast disease: magnetic resonance and radiofrequency pulse sequences. , 1985, AJR. American journal of roentgenology.