European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability.

A semi-anthropomorphic 'distal radius like' phantom, developed by Kalender and Ruegsegger for use in peripheral bone densitometry using single photon (DPA) dual X-ray (DXA) and quantitative computed tomography (QCT) machines, has been studied with a view to cross-calibrating different types and brands of densitometers in current use. In the context of an EU 'Concerted Action' (second Framework Programme) the phantom was repeatedly measured on six SPA machines, three DXA machines and nine QCT machines (545 measurements). Linear regression equations were derived, individual to each machine, which allowed the derivation of 'standardized densities'. In this way we converted measurements made by machines of the same modality to a common scale of measurements. Two machines (one DXA, one SPA) showed statistically significant instability over time emphasising the need for rigorous quality control in the application of densitometry. In other respects these results provide an encouraging basis for the derivation of standardized normative ranges and the more effective use of peripheral densitometry in future clinical and epidemiological studies.

[1]  W A Kalender,et al.  A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications. , 1992, Medical Physics (Lancaster).

[2]  P. Schneider,et al.  [Peripheral quantitative computed tomography for bone mineral measurement using a new special QCT-scanner. Methodology, normal values, comparison with manifest osteoporosis]. , 1991, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[3]  Klaus Engelke,et al.  Universal standardization for dual X‐ray absorptiometry: Patient and phantom cross‐calibration results , 1994, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[4]  P. Rüegsegger,et al.  High-contrast resolution of CT images for bone structure analysis. , 1992, Medical physics.

[5]  W. Kalender,et al.  Multicentre European COMAC-BME study on the standardisation of bone densitometry procedures. , 1993, Technology and health care : official journal of the European Society for Engineering and Medicine.

[6]  R. Neer The utility of single-photon absorptiometry and dual-energy x-ray absorptiometry. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  T. Kelly,et al.  Calibration and standardization of bone mineral densitometers , 1989, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[8]  S Ortolani,et al.  Bone mass measurement by DXA: Influence of analysis procedures and interunit variation , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[9]  W. Kalender,et al.  A phantom for standardization and quality control in peripheral bone measurements by PQCT and DXA , 1993 .