SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues.
暂无分享,去创建一个
G. Gabriel | R. Villa | R. Hernandez | M. Tijero | J. Berganzo | J. Caro | A. Altuna | F. Blanco | R. Salido | L. Fernández
[1] Wilfried Mokwa,et al. Medical implants based on microsystems , 2007 .
[2] E. Gdoutos,et al. Nonlinear behavior of composite sandwich beams in three-point bending , 2001 .
[3] David C. Martin,et al. A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex , 2005, Journal of neural engineering.
[4] W. Olbricht,et al. Fabrication and characterization of microfluidic probes for convection enhanced drug delivery. , 2006, Journal of controlled release : official journal of the Controlled Release Society.
[5] E. Gersing,et al. Messung der elektrischen Impedanz von Organen — Apparative Ausrüstung für Forschung und klinische Anwendung - Measurement of Electrical Impedance in Organs – Measuring Equipment for Research and Clinical Applications , 1991 .
[6] Chenyang Xu,et al. Design and Fabrication of A High Density Metal Microelectrode Array for Neural Recording , 2002 .
[7] G. Kotzar,et al. Evaluation of MEMS materials of construction for implantable medical devices. , 2002, Biomaterials.
[8] Jiping He,et al. Biocompatible benzocyclobutene-based intracortical neural implant with surface modification , 2005 .
[9] S. Aoyagi,et al. Biodegradable Polymer Needle Having a Trench for Collecting Blood by Capillary Force , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.
[10] Jack W. Judy,et al. Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process , 2005, IEEE Transactions on Biomedical Engineering.
[11] Richard J. Farris,et al. The characterization of thermal and elastic constants for an epoxy photoresist SU8 coating , 2002 .
[12] Han-Qing Yu,et al. An innovative microelectrode fabricated using photolithography for measuring dissolved oxygen distributions in aerobic granules. , 2007, Environmental science & technology.
[13] E. Gersing. Impedance spectroscopy on living tissue for determination of the state of organs , 1998 .
[14] Design and Fabrication Issues in Affinity Cantilevers for bioMEMS Applications , 2006, Journal of Microelectromechanical Systems.
[15] T. Tønnessen,et al. PCO2 electrodes at the surface of the kidney detect ischaemia , 1996, Acta anaesthesiologica Scandinavica.
[16] J. Hetke,et al. Strength characterization of silicon microprobes in neurophysiological tissues , 1990, IEEE Transactions on Biomedical Engineering.
[17] Rosa Villa,et al. Manufacturing and full characterization of silicon carbide-based multi-sensor micro-probes for biomedical applications , 2007, Microelectron. J..
[18] Rosa Villa,et al. A SiC microdevice for the minimally invasive monitoring of ischemia in living tissues , 2006, Biomedical microdevices.
[19] J. Loubet,et al. Strain-rate effects on Hardness of glassy polymers in the nanoscale range. Comparison between quasi-static and continuous stiffness measurements , 1999 .
[20] P. Renaud,et al. SU-8 nanocomposite photoresist with low stress properties for microfabrication applications , 2006 .
[21] K. Wise,et al. A multichannel neural probe for selective chemical delivery at the cellular level , 1997, IEEE Transactions on Biomedical Engineering.
[22] K. Mabuchi,et al. Parylene flexible neural probes integrated with microfluidic channels. , 2005, Lab on a chip.
[23] M. Allen,et al. Microfabricated microneedles for gene and drug delivery. , 2000, Annual review of biomedical engineering.
[24] Justin C. Williams,et al. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.
[25] P. Renaud,et al. Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. , 2004, Biosensors & bioelectronics.
[26] Rebecca S. Shawgo,et al. Biocompatibility and biofouling of MEMS drug delivery devices. , 2003, Biomaterials.
[27] L. Geddes. Electrodes and the measurement of bioelectric events , 1972 .
[28] A. Leaf,et al. The role of cell swelling in ischemic renal damage and the protective effect of hypertonic solute. , 1972, The Journal of clinical investigation.
[29] Jiping He,et al. Polyimide-based intracortical neural implant with improved structural stiffness , 2004 .
[30] C. Chung,et al. Surface modification of SU8 photoresist for shrinkage improvement in a monolithic MEMS microstructure , 2007 .
[31] R. Villa,et al. Minimally invasive silicon probe for electrical impedance measurements in small animals. , 2003, Biosensors & bioelectronics.
[32] S. Takeuchi,et al. Fabrication of Flexible Neural Probes With Built-In Microfluidic Channels by Thermal Bonding of Parylene , 2006, Journal of Microelectromechanical Systems.
[33] David C. Martin,et al. In vivo studies of polypyrrole/peptide coated neural probes. , 2003, Biomaterials.
[34] Justin C. Williams,et al. Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.
[35] Manhee Han,et al. A novel fabrication process for out-of-plane microneedle sheets of biocompatible polymer , 2007 .