Traceability and uncertainty of vocal parameters estimated through a contact microphone

This paper focuses on the definition of calibration procedures that ensure the traceability of parameters estimated by vocal analyzers based on a contact microphone. The common estimated parameters are sound pressure level, fundamental frequency and time dose, which have been proposed for diagnostic purposes. An analysis is also proposed in order to estimate the uncertainty of the investigated parameters, taking the contributions related to the defined calibration procedures into account. Specific tests will be also defined in order to identify the main influence quantities and their effects on the estimated parameters. Preliminary results are reported that refer to a device developed by the authors, which uses an electret condenser microphone as the contact microphone.

[1]  Robert E. Hillman,et al.  Ambulatory Monitoring of Daily Voice Use , 2011 .

[2]  Arianna Astolfi,et al.  Design Issues for a Portable Vocal Analyzer , 2013, IEEE Transactions on Instrumentation and Measurement.

[3]  Ingo R Titze,et al.  Estimation of sound pressure levels of voiced speech from skin vibration of the neck. , 2005, The Journal of the Acoustical Society of America.

[4]  Ingo R Titze,et al.  Adaptation of a Pocket PC for use as a wearable voice dosimeter. , 2005, Journal of speech, language, and hearing research : JSLHR.

[5]  Robert E Hillman,et al.  Ambulatory Monitoring of Disordered Voices , 2006, The Annals of otology, rhinology, and laryngology.

[6]  Susan Thibeault,et al.  Prevalence of voice disorders in teachers and the general population. , 2004, Journal of speech, language, and hearing research : JSLHR.

[7]  V. Boucher Acoustic correlates of fatigue in laryngeal muscles: findings for a criterion-based prevention of acquired voice pathologies. , 2008, Journal of speech, language, and hearing research : JSLHR.

[8]  Pasquale Bottalico,et al.  Relationship between vocal doses and voice disorders on primary school teachers , 2012 .

[9]  A. Carullo,et al.  A low-cost platform for voice monitoring , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[10]  Robert E Hillman,et al.  Development and testing of a portable vocal accumulator. , 2003, Journal of speech, language, and hearing research : JSLHR.

[11]  J. Švec,et al.  Vocal dose measures: quantifying accumulated vibration exposure in vocal fold tissues. , 2003, Journal of speech, language, and hearing research : JSLHR.

[12]  Cheol-Ho Jeong,et al.  Vocal effort with changing talker-to-listener distance in different acoustic environments. , 2011, The Journal of the Acoustical Society of America.

[13]  Ingo R. Titze,et al.  Technical considerations in the design of a wearable voice dosimeter , 2002 .

[14]  Ingo R Titze,et al.  Quantifying Vocal Fatigue Recovery: Dynamic Vocal Recovery Trajectories after a Vocal Loading Exercise , 2009, The Annals of otology, rhinology, and laryngology.