Low Vision (LV) due to Age Related Macular Degeneration (AMD), Glaucoma or Retinitis Pigmentosa (RP) is a growing problem, which will affect more than 15 million people in the U.S alone in 2010. Low Vision Aid Goggles (LVG) have been under development at Ben-Gurion University and the Holon Institute of Technology. The device is based on a unique Image Transceiver Device (ITD), combining both functions of imaging and Display in a single chip. Using the ITD-based goggles, specifically designed for the visually impaired, our aim is to develop a head-mounted device that will allow the capture of the ambient scenery, perform the necessary image enhancement and processing, and re-direct it to the healthy part of the patient's retina. This design methodology will allow the Goggles to be mobile, multi-task and environmental-adaptive. In this paper we present the optical design considerations of the Goggles, including a preliminary performance analysis. Common vision deficiencies of LV patients are usually divided into two main categories: peripheral vision loss (PVL) and central vision loss (CVL), each requiring different Goggles design. A set of design principles had been defined for each category. Four main optical designs are presented and compared according to the design principles. Each of the designs is presented in two main optical configurations: See-through system and Video imaging system. The use of a full-color ITD-Based Goggles is also discussed.
[1]
E M Yeatman,et al.
Surface-plasmon spatial light modulators based on liquid crystal.
,
1992,
Applied optics.
[2]
James S Wolffsohn,et al.
A review of current knowledge on Electronic Vision Enhancement Systems for the visually impaired
,
2003,
Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.
[3]
E. Peli.
Contrast in complex images.
,
1990,
Journal of the Optical Society of America. A, Optics and image science.
[4]
P. Artes,et al.
Face recognition in age related macular degeneration: perceived disability, measured disability, and performance with a bioptic device
,
2002,
The British journal of ophthalmology.
[5]
JoÈrgen Gustafssona,et al.
PII: S0275-5408(01)00011-4
,
.
[6]
Eli Peli.
Contrast sensitivity function (CSF) and image discrimination
,
1999,
Electronic Imaging.
[7]
Uzi Efron,et al.
A CMOS/LCOS image transceiver chip for smart goggle applications
,
2004,
IEEE Transactions on Circuits and Systems for Video Technology.
[8]
Barry T. Thomas,et al.
Head-Mounted Mobility Aid for Low Vision Using Scene Classification Techniques
,
1998,
Int. J. Virtual Real..